Member Login
Search
Jump to a Date
Sponsored Communities
Cool stuff
Neat Stuff

Visit our shop for nerds in control lifestyle products.
Thermal Overload
The threads that wouldn't die...
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
Fortune
Fortune's Real-Life Courtroom Quote #52:
Q: What is your name?
A: Ernestine McDowell.
Q: And what is your marital status?
A: Fair.
Q: What is your name?
A: Ernestine McDowell.
Q: And what is your marital status?
A: Fair.
RSS Feed
www.control.com/rss/
To get a personalized feed, become a member at no cost.
I would like known if modbus have support to multimater message. I need link two master controller, and I don`t known if is possible use the modbus TCP.
Thanks
Bruno
Thanks
Bruno
I have used ModbusTCP in applications where the PLCs are getting polled from 2 different masters which are not synchronized, and it works well. In fact, I can connect to the PLC with the ladder logic interface program with my laptop while the PLCs are still being polled by the masters with no ill effects. The ethernet speed of the connections on the PLC is what keeps things running, and I would say there are very few instances where 2 different messages are arriving at the PLC at the exact same time. You should have no problems, and if you do notice excessive data collisions, you could reduce polling speed slightly. Once you use this, you won't want to use serial communications any more than you absolutely have to. Good luck!
Pat
Pat
Base on my experience, you can used HMS - Anybus... please check http://www.anybus.com
Modbus serial = 1 master per network, modbus ethernet Tcp/IP = peer to peer (ie multi-master). If you must use serial and need multimaster you will need a device in the middle such as a prolinx gateway that can talk to the device, store the data into dual port ram and then allow the data to be accessed on 2 additional ports.
Modbus/TCP is a client/server protocol that supports multiple masters. One thing to watch out for is low-powered embedded devices that only support one connection at a time, in which case only one master would be able to communicate with the slave at a time.
To familiarize yourself with Modbus/TCP, you can download a fully functioning Modbus/TCP master and slave ActiveX Control from Automated Solutions' website http://www.automatedsolutions.com.
You can run the pre-built example applications on one or more PCs to demonstrate Modbus/TCP capability.
To familiarize yourself with Modbus/TCP, you can download a fully functioning Modbus/TCP master and slave ActiveX Control from Automated Solutions' website http://www.automatedsolutions.com.
You can run the pre-built example applications on one or more PCs to demonstrate Modbus/TCP capability.
From Control Engineering magazine...
Related articles from Control
Engineering magazine- ODVA announces new editions of CIP network specifications and testing of Ethernet/IP products
- Molex releases new connection system and expanded line of Ethernet switches
- Synapse Wireless California Eastern Laboratories form partnership
- Prosoft introduces wireless 802.11g point I/O adapter and appliance transaction manager
- Belden releases new continuous flex Ethernet cables
- Easier startup: Petropiar Oil Refining Facility is 2008 HART Plant of the Year
- Embedding wireless: one chip, security platform
- Wireless manager for instrumentation and control devices
- New podcast: One road to wireless instrumentation
- Upgraded communication modules make PLC to PLC communications easier
Above articles copyright 2008 Reed Business Information.
Subject to its Terms of Use.
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.
Our Advertisers
Help keep our servers running...
Patronize our advertisers!
Patronize our advertisers!




