Member Login
Search
Jump to a Date
Sponsored Communities
Cool stuff
Twitter Feed
Neat Stuff

Visit our shop for nerds in control lifestyle products.
Thermal Overload
The threads that wouldn't die...
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
Fortune
Even though they raised the rate for first class mail in the United
States we really shouldn't complain -- it's still only two cents a
day.
States we really shouldn't complain -- it's still only two cents a
day.
RSS Feed
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Hi folks:
I have been put into a rather peculiar position with a customer due to a light curtain issue.
Basically, the customer has insisted on using brand "x" light curtain because they advertise that they are the only manufacturer who is
compliant with some new IEC standard regarding machine safety. I believe the standard number is like IEC-61496-1&2 or something like that. Another standard that might be applied is IEC-62046-1.
Anyhow, there are issues with this curtain product. It is highly sensitive to ambient light changes, it takes 2 minutes to power the device up or recover from a "fault condition", and it needs to be reset twice to work once. To point, we have faulted out this light curtain product already with a "balding man" walking near the array. Talking to the other major brand
manufacturers and they all say "What Standard - sounds like a BS sales pitch to us."
My questions: Is this standards change for real? Has anyone else heard of this? Is it now going to be standard to have a 2 minute power on cycle for a safety device? Have we been fed a BS line from the sales folk?
-----
Ron Gage - Saginaw, MI
(ron@rongage.org)
I have been put into a rather peculiar position with a customer due to a light curtain issue.
Basically, the customer has insisted on using brand "x" light curtain because they advertise that they are the only manufacturer who is
compliant with some new IEC standard regarding machine safety. I believe the standard number is like IEC-61496-1&2 or something like that. Another standard that might be applied is IEC-62046-1.
Anyhow, there are issues with this curtain product. It is highly sensitive to ambient light changes, it takes 2 minutes to power the device up or recover from a "fault condition", and it needs to be reset twice to work once. To point, we have faulted out this light curtain product already with a "balding man" walking near the array. Talking to the other major brand
manufacturers and they all say "What Standard - sounds like a BS sales pitch to us."
My questions: Is this standards change for real? Has anyone else heard of this? Is it now going to be standard to have a 2 minute power on cycle for a safety device? Have we been fed a BS line from the sales folk?
-----
Ron Gage - Saginaw, MI
(ron@rongage.org)
I use the Lenze lumiflex, ER 30 - 1500. It meets
IEC 61496. It works well, is not very sensitive to ambient light
changes, and needs only one reset. I have not tested it with balding men.
IEC 61496. It works well, is not very sensitive to ambient light
changes, and needs only one reset. I have not tested it with balding men.
It is important that products are according IEC. So a product is expected to have a certain quality in functionality. But knowing what is told in a IEC number gives the sales people a advantage.
Perhaps talking to the IEC will help to give you more information on your problem. www.iec.ch
Good luck, Sisko Bos
sisko.bos@jbbesturingstechniek.nl
Perhaps talking to the IEC will help to give you more information on your problem. www.iec.ch
Good luck, Sisko Bos
sisko.bos@jbbesturingstechniek.nl
IEC1496 parts 1 and 2 are applicable to light curtains world wide, however certification to this standard is not a requirement in North America. There are various standards that apply to the design, manufacture and use of light curtains, however the USA does not have test standard for light curtains with the same degree of detail as IEC61496. There are many manufacturers of light curtains whose products have been certified to meet IEC61496. Certification provides a measure of comfort regarding the product. However since it is not a requirement in the USA and since there is no enforcement or checking, the product may only be "designed to meet" and not really be certified to meet the standards. It may be a marketing game or it may be real. Regardless of the certification, you must get satisfactory performance from the product and feel comfortable about the supplier.
Hi Romerta,
I need to investigate if there are any standards in USA regarding use and installation of light curtains in industrial environment.
You say: "...There are various standards that apply to the design, manufacture and use of light curtains..." Are you talking about international standards?. Where can I get more info on IEC61496?
Thanks
Henry
I need to investigate if there are any standards in USA regarding use and installation of light curtains in industrial environment.
You say: "...There are various standards that apply to the design, manufacture and use of light curtains..." Are you talking about international standards?. Where can I get more info on IEC61496?
Thanks
Henry
Within the USA, OSHA's reference to light curtains is OSHA 1910.217. However there are many ANSI references relating to the application and use of light curtains. The most popular and generally applicable of the ANSI standards are ANSI B11.19 and ANSI /RIA R15.06. These detail the selection, application, integration and use of light curtains. As far the design and manufacture of light curtains, presently the most exacting and detailed standard is IEC/EN 61496.
If you have any further questions, please feel free to contact me at roberta.nelson.shea@honeywell.com.
Roberta
If you have any further questions, please feel free to contact me at roberta.nelson.shea@honeywell.com.
Roberta
Hi Ron,
I need to investigate if there are any current standards, or requirements, on use of light curtains in industrial environment. You have mentioned couple of standards: IEC-61496-1&2 and IEC-62046-1. Can you tell me where can I get information about these standards?
I would greatly appreciate any leads.
Thank you very much
I need to investigate if there are any current standards, or requirements, on use of light curtains in industrial environment. You have mentioned couple of standards: IEC-61496-1&2 and IEC-62046-1. Can you tell me where can I get information about these standards?
I would greatly appreciate any leads.
Thank you very much
Henry,
I'm with Scientific Technologies, one of leading safety light curtain manufacturers. I have a couple of links for you that might help explain IEC61496 (1&2):
http://www.ce-mag.com/archive/1999/marchapril/Jacobs en.html
http://www.frostcontrolsinc.com/old/FrostControlsWebsite/Frost _Local/page11.htm
You can also get copies of the standard from:
www.global.ihs.com (IEC 61496 Part 1 $134.00, IEC 61496 Part 2 $108.00).
Note that all the major suppliers now offer at least some safety light curtains that meet the IEC61496 standard.
Best regards,
Tom Knauer
Scientific Technologies, Inc.
I'm with Scientific Technologies, one of leading safety light curtain manufacturers. I have a couple of links for you that might help explain IEC61496 (1&2):
http://www.ce-mag.com/archive/1999/marchapril/Jacobs en.html
http://www.frostcontrolsinc.com/old/FrostControlsWebsite/Frost _Local/page11.htm
You can also get copies of the standard from:
www.global.ihs.com (IEC 61496 Part 1 $134.00, IEC 61496 Part 2 $108.00).
Note that all the major suppliers now offer at least some safety light curtains that meet the IEC61496 standard.
Best regards,
Tom Knauer
Scientific Technologies, Inc.
Are you concerned with meeting European standards or USA or Canadian? The answer is different depending on the country of end-use.
If you have any further questions, please feel free to contact me at roberta.nelson.shea@honeywell.com.
If you have any further questions, please feel free to contact me at roberta.nelson.shea@honeywell.com.
Mr. Gage,
I was just surfing the web and I noticed your message regarding the E30-1500 light curtain. I am the Engineering Sales Manager for Leuze Lumiflex in the US. The issues that you have mentioned are absolutely not normal conditions. This particular light curtain is extremely immune to changes in ambient light. It is almost impossible to find a way to fault out the light curtain from light changes. The startup time of the light curtain is much faster than 2 minutes, it is in the miliseconds range. You should not be getting a fault signal at all unless there is some type of hardware problem with the curtain. I believe that this particular unit has a hardware fault that is causing your problems. I realize that this message is pretty old and I am sure that you have already resolved the issue, but I want to assure you that in working with this product for several years it is extremely reliable. Please let me know how things worked out and also if you have any questions.
Thank You,
Ken Naughton
Leuze Lumiflex, Inc.
I was just surfing the web and I noticed your message regarding the E30-1500 light curtain. I am the Engineering Sales Manager for Leuze Lumiflex in the US. The issues that you have mentioned are absolutely not normal conditions. This particular light curtain is extremely immune to changes in ambient light. It is almost impossible to find a way to fault out the light curtain from light changes. The startup time of the light curtain is much faster than 2 minutes, it is in the miliseconds range. You should not be getting a fault signal at all unless there is some type of hardware problem with the curtain. I believe that this particular unit has a hardware fault that is causing your problems. I realize that this message is pretty old and I am sure that you have already resolved the issue, but I want to assure you that in working with this product for several years it is extremely reliable. Please let me know how things worked out and also if you have any questions.
Thank You,
Ken Naughton
Leuze Lumiflex, Inc.
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.
advertisements
Servo, stepping motor control, analog & web HMI in one system!
Find the right Modbus device for your project... or list your Modbus device on the largest online Modbus device directory.
Control.com is the largest Automation community on the web. Learn how to advertise here now...
Our Advertisers
Help keep our servers running...
Patronize our advertisers!
Patronize our advertisers!