Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
If you want to know what god thinks of money, just look at the people
he gave it to.
-- Dorthy Parker
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Friday, October 5, 2007
from the Purchasing department...
STAL LAVAL GT-35B
Topic: Engineering and workplace issues.
Posted by hyder on 5 October, 2007 - 11:53 pm
I need to know the spare parts supplier for STAL LAVAL GT-35B
from the instrument department...
FISCO
Topic: Engineering and workplace issues.
Posted by kzpc on 5 October, 2007 - 11:53 pm
FISCO concept
from the Automation List department...
PC Based Digital I/O
Topic: Computers in manufacturing; also hardware discussion.
Originally posted by JJ on 26 September, 2007 - 11:36 pm
Needing recommendations for high speed PC based digital I/O.
New Replies:
By Curt Wuollet on 5 October, 2007 - 11:52 pm -
> Well, you're a diehard Linux fan, so it figures. I like the IDEA of all that you're arguing...
By Curt Wuollet on 5 October, 2007 - 11:37 pm -
That can actually work both ways. I've found much less tendency to tamper with the system. If the...
from the Is it possible?? department...
PLC Programmable
Topic: Software, including programming, OS issues, etc.
Originally posted by Berend on 2 October, 2007 - 1:53 am
I have a question concerning the issue: Is a Siemens S5 programmable with a programming language?
New Replies:
By PeterM on 5 October, 2007 - 11:51 pm -
I always thought STEP5 was akin to Assembly programming!...
By Michael Griffin on 5 October, 2007 - 11:38 pm -
The S5 PLC has an interpreter built in which runs a programming language called "S5 statement...
from the Automation List department...
Why is current transformer secondary short circuited?
Topic: Engineering and workplace issues.
Originally posted by Anonymous on 6 June, 2007 - 11:47 pm
Why is current transformer secondary short circuited during the operation?
New Replies:
By raghu on 5 October, 2007 - 11:41 pm -
Basically a ct is a step up transformer, normally in the primary of a ct high currents are...
from the Leading the march against AB PV+ department...
PC based HMI
Topic: Human-Machine Interface and SCADA.
Originally posted by John on 11 September, 2007 - 12:25 am
I am looking to get away from the rule of AB, and would like the flexibilty of a PC based HMI.
New Replies:
By Nicolas Kunzer on 5 October, 2007 - 10:55 pm -
Hi John, You can try PCVUE. If you want a cost effective and good Scada, this is the one! ...
from the Automation List department...
Thermal Relief Valves
Topic: Application Questions and Problems
Posted by Anonymous on 5 October, 2007 - 10:54 pm
Selection of thermal relief valves
from the jVens department...
Power rating of an AC motor
Topic: Motion control, servos, steppers, etc.
Originally posted by Jan on 3 October, 2007 - 12:10 am
AC motor Power rating
New Replies:
By Curt Wuollet on 5 October, 2007 - 10:52 pm -
By all means. Torque is proportional to current. Regards cww...
from the Automation List department...
Vijeo Look VBA access to in-symbol variables
Topic: Human-Machine Interface and SCADA.
Originally posted by Raycho Raykov on 11 September, 2007 - 11:48 pm
How to find the name of "real" (@) variable using VBA if I know the name of "local" (%) variable inside of symbol script?
New Replies:
By Nicolas Kunzer on 5 October, 2007 - 10:51 pm -
Hi Raycho Raykov, That's right, you cannot access the variable animated inside the symbol. To...
Topic: Application Questions and Problems
Originally posted by pmmeeran on 6 December, 2006 - 8:52 pm
We have a GE Frame 6, DLN.2 gas Turbine. During startup while changing the mode at 82% of speed from primary to lean-lean the GT tripped on exhaust temperature very high.
New Replies:
By CSA on 5 October, 2007 - 10:49 pm -
Thank you for the feedback. Since markvguy stopped posting it seems some individuals don't feel the...
from the Electrical & Instrumentation department...
Communication Woodward (protocol CAN bus) with HC900 (Protocol Modbus)
Topic: Communications systems and equipment.
Originally posted by Taufik on 14 February, 2006 - 10:25 pm
How to communication WoodWard (CAN Bus) with HC900 (Modbus RTU or TC/IP)
New Replies:
By Henrik Ebeklint on 5 October, 2007 - 11:17 am -
IntelliCom has communication solutions for Genset applications. The NetBiter device can communicate...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!