Member Login
Search
Jump to a Date
Sponsored Communities
Cool stuff
Neat Stuff

Visit our shop for nerds in control lifestyle products.
Thermal Overload
The threads that wouldn't die...
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
Fortune
"To vacillate or not to vacillate, that is the question ... or is it?"
RSS Feed
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Posts from...
Saturday, October 6, 2007Reading and writing to Watson-Marlow pumps using RS232
New Replies:
By Sheng on 6 October, 2007 - 7:25 pm -
By Sheng on 6 October, 2007 - 7:25 pm -
you need to open up the labview sample "basic write and read". in the upper window...
In need of a air mass flow meter and a flow meter for diesel.
New Replies:
By syurish on 6 October, 2007 - 3:38 pm -
By syurish on 6 October, 2007 - 3:38 pm -
This should be useful:
List of Flow Sensors Manufacturers
...
By Walt Boyes on 6 October, 2007 - 12:27 am - You are not wrong in your recommendations, Rohit, but since this is a neutral, non-commercial...
PLC for oil rig control
New Replies:
By serial_RJ485 on 6 October, 2007 - 3:19 pm -
By serial_RJ485 on 6 October, 2007 - 3:19 pm -
An ideal PLC for Rig Control should have:
1. Conformally coated I/O and Controller to handle...
By Rick on 6 October, 2007 - 12:15 am - Well, as I know, Siemens S7 3xx and 4xx is a good example. You can Google its training materials....
FISCO concept
New Replies:
By A.K.Hait on 6 October, 2007 - 3:18 pm -
By A.K.Hait on 6 October, 2007 - 3:18 pm -
FISCO is Fieldbus Intrinsically Safe Concept. Another concept is FINICO concept. I have not heard...
Output of frame 6551B GE Gas turbine generator reduced to nearly 1 MW after Major Overhauling.
New Replies:
By CSA on 6 October, 2007 - 3:17 pm -
By CSA on 6 October, 2007 - 3:17 pm -
Many times transducers drift and indicate higher than normal output before they are calibrated. If...
By CSD on 6 October, 2007 - 9:30 am - You mentioned IGV Blading, pinion etc have been changed. Did you calibrate IGVs after this change?...
By A. Kumar on 6 October, 2007 - 9:29 am - We are also experiencing a similar problem here as we have lost few MWs after comustion inspection...
By sheikh_arif on 6 October, 2007 - 12:45 am - Thanks to CSA for responsing. Here I try to provide the info you asked for:
1. We didn't change...
Calculation of phase to phase voltage
New Replies:
By anon on 6 October, 2007 - 3:16 pm -
By anon on 6 October, 2007 - 3:16 pm -
Square root of 3 times line to neutral volage for Y config....
Incremetal Enocder and how it works with PLC
I have relatively no knowledge of PLC's and PLC programming but am keen to learn. What's the best system to learn the subject and how to approach it?
New Replies:
By steve on 6 October, 2007 - 10:05 am -
By steve on 6 October, 2007 - 10:05 am -
just read this post and if you want a really good course tutor on any plc system i'd recommend a...
By Dave S. on 6 October, 2007 - 12:36 am - Gary,
Go to thelearningpit.com
That is by far the best online resource available for anyone to...
Looking for articles/publications/presentations on PCS technology selection.
New Replies:
By Sugi on 6 October, 2007 - 10:04 am -
By Sugi on 6 October, 2007 - 10:04 am -
Hello I have been recently "know" and operating the siemens PCS7 and a few years a go...
Balancing load in parallel electric generator
New Replies:
By Anonymous on 6 October, 2007 - 9:35 am -
By Anonymous on 6 October, 2007 - 9:35 am -
I believe the gensets shall remains in DROOP to allow voltage and frequency (thus Q and P) to...
By Chaterpilar on 6 October, 2007 - 12:09 am - Hello Luigi,
Well, first of all few tips.
Let us say 2 gens are running in parallel, then...
Part-time embedded training
New Replies:
By Buvana on 6 October, 2007 - 9:33 am -
By Buvana on 6 October, 2007 - 9:33 am -
Hi
iSource Technologies, a total IT solution provider from Bangalore focuses on Web Enabled...
replacement for a Raimondi globe valve
How to connect PC & PLC with ASCII interface?
New Replies:
By serial_RJ45 on 6 October, 2007 - 12:47 am -
By serial_RJ45 on 6 October, 2007 - 12:47 am -
1. You will need TwidoSuite, free from Schneider website.
...
By Mark on 6 October, 2007 - 12:29 am - If you configure the Twido port for Modbus, Automated Solutions offers several solutions for...
Servo valve adjustment (MOOG).
New Replies:
By CSA on 6 October, 2007 - 12:46 am -
By CSA on 6 October, 2007 - 12:46 am -
It's been longer than 20 years since I've worked on a Mark II, but if I remember correctly the...
By rock313 on 6 October, 2007 - 12:08 am - But if it's not servo-valve, what do you think causing the problem? Is it from starting motor, or...
healy Ruff 940135-001 Mini Pro
Is it possible to have standalone FCS by Yokogawa?
New Replies:
By Walt Boyes on 6 October, 2007 - 12:32 am -
By Walt Boyes on 6 October, 2007 - 12:32 am -
Since Chevron recently announced that they were moving from their previous vendor to Yokogawa, you...
A bit confused about the protocol layers.
Is DI water good for compressor wash?
New Replies:
By brian hall on 6 October, 2007 - 12:23 am -
By brian hall on 6 October, 2007 - 12:23 am -
Where did you get the 16-20 degree number? We perform washes frequently here and always use hot...
Trouble on running WindowMaker
Interpretation of Transfer Function
New Replies:
By student on 6 October, 2007 - 12:06 am -
By student on 6 October, 2007 - 12:06 am -
This is the equation of a valve positioner with its valve side tubing removed and connected to a...
Can anyone send me the mid value selection scheme with write up for training purpose?
Inlet separator interface level mesurement - want to share the experience of people having field experience.
New Replies:
By tavakol on 6 October, 2007 - 12:04 am -
By tavakol on 6 October, 2007 - 12:04 am -
Dear sir,
If your seperator is full of both water & oil, displacer and dp cell work properly...
I am trying to set up a Read/Write communications from S7 PLC to a Quantum using the S7 Modbus TCP Driver from Siemens. I am having difficulty getting any communication between the two...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.
Our Advertisers
Help keep our servers running...
Patronize our advertisers!
Patronize our advertisers!









