Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
Rules:
(1) The boss is always right.
(2) When the boss is wrong, refer to rule 1.
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Sunday, October 14, 2007
from the HMI animation department...
Clearing a text field on RSView32 using VB code
Topic: Human-Machine Interface and SCADA.
Originally posted by jorge nieves on 10 October, 2007 - 11:49 pm
How do I implement VB code to clear the text fields in RSView32?
New Replies:
By HelpingHand on 14 October, 2007 - 9:06 pm -
Associated with every String Input object is a HMI tag of type string. A Tag object can be accessed...
from the Projects department...
Premium PLC Communication
Topic: Communications systems and equipment.
Originally posted by Rahul Patil on 11 October, 2007 - 12:18 am
Communicating with two Premium PLCs through ethernet module
New Replies:
By serial_RJ45 on 14 October, 2007 - 9:05 pm -
Connect both PLCs to a common ethernet switch or hub....
By aggattapauer on 14 October, 2007 - 8:24 pm -
You may use I/O SCANNING. It's very easy to configure and it's not necessary to write any line of...
By Dweebyone on 14 October, 2007 - 8:23 pm -
READ_VAr, or WRITE_VAR if conditional. IO scanner if continous. Read Communications manual supplied...
By ROD on 14 October, 2007 - 8:23 pm -
Communication via TCP is very simple when using the I/O scanner of the PLC's. Just fill in the...
By Robert Willis on 14 October, 2007 - 8:23 pm -
You have not mentioned what programming software or specific Ethernet modules or processors that...
from the Automation List department...
Embedded systems training
Topic: Information resources, documentation.
Originally posted by P. Samuthira Pandi on 13 May, 2004 - 6:46 pm
I want to have a training in embedded systems in India.
New Replies:
By Narasimma Rao on 14 October, 2007 - 9:00 pm -
Hi Guys, I done my Mtech embbeded projects at Pantech Solutions, they guided me well in the...
from the Instrumentation department...
application of steam to the mass flowmeters
Topic: Information resources, documentation.
Originally posted by kamit patel on 29 September, 2007 - 2:25 pm
I want to get the information about the application of steam to the mass flowmeters.
New Replies:
By Rohit Chandak on 14 October, 2007 - 9:00 pm -
Satish, Transit Time Ultrasonic is only used for clean liquids where as Doppler based Ultrasonic...
from the control department...
combustion chamber type
Topic: Engineering and workplace issues.
Originally posted by kakil on 8 October, 2007 - 3:52 pm
what is mean DLN-1 AND DLN-2
New Replies:
By nanda on 14 October, 2007 - 8:59 pm -
yes you r correct... if you need any documentation on how to control emission on gasturbines... i...
from the PullsMyHairOut department...
TSX FPP20 card driver on WinXP
Topic: Local and wide area networking in factory automation.
Originally posted by Eric Klaasen on 4 October, 2007 - 9:42 pm
We installed a TSX FPP20 PCMCIA card on a new PC running WinXP. We used the latest Fipway drivers from the Telemecanique website. We can not get this configuration to work. Has anyone got experience or know how to solve this problem?
New Replies:
By Eric Klaasen on 14 October, 2007 - 8:58 pm -
thanks, that makes sence, where can I downlod that from? I downloaded the latest version from the...
from the Electrical department...
Automatic Bus transfer function
Topic: Engineering and workplace issues.
Originally posted by karthi on 14 October, 2007 - 6:11 pm
need details about automatic busbar transfer function
New Replies:
By Phil Corso, PE on 14 October, 2007 - 8:57 pm -
What do you mean by "details?" Regards, Phil Corso, PE...
from the more marketing foolderah department...
what is HART wireless?
Topic: Communications systems and equipment.
Originally posted by Issac on 14 October, 2007 - 6:11 pm
Is HART wireless HART without wires? or forced obsolescence?
New Replies:
By Walt Boyes on 14 October, 2007 - 8:57 pm -
See the August and Septwmber issues of Control, available in downloadable PDF format at...
from the Communications CCM- 1746-BAS department...
CCM (Caterpillar) 1746-BAS (Allen-Bradley)
Topic: Communications systems and equipment.
Originally posted by SEGUNDO AMORES on 31 January, 2007 - 12:10 am
CCM communicating 1746-BAS (Caterpillar)
New Replies:
By Doyle Taylor on 14 October, 2007 - 8:54 pm -
We have a device that resides directly on the CAT Data Link, just like the CCM Module, and provide...
from the Automation List department...
S7 to Quantum - Modbus communications
Topic: Communications systems and equipment.
Originally posted by A Dobson-Holt on 6 October, 2007 - 12:03 am
I am trying to set up a Read/Write communications from S7 PLC to a Quantum using the S7 Modbus TCP Driver from Siemens. I am having difficulty getting any communication between the two...
New Replies:
By ROD on 14 October, 2007 - 8:39 pm -
Hi Guys, there is nothing to configure in the Quantum PLC, this will always answer on MB/TCP...
from the Automation List department...
Fault Tolerant Ethernet and Industrial Ethernet,
Topic: PLCs and related questions.
Originally posted by Marzie on 7 October, 2007 - 11:53 am
Difference between a Fault Tolerant Ethernet and Industrial Ethernet,
New Replies:
By Marzie on 14 October, 2007 - 8:37 pm -
Thanks.do you know is it possible to connect SIEMENS PLCs to Honeywell DCS(C300 controller) through...
from the Automation List department...
level sensing and tank shape
Topic: Sensor technologies.
Originally posted by jeff on 9 October, 2007 - 12:24 pm
Does tank shape affect pressure?
New Replies:
By balu on 14 October, 2007 - 8:36 pm -
I recently added 2 sensors. One is lower sensor another is upper sensor. Here mainly i am...
By steve on 14 October, 2007 - 5:50 pm -
Hi- It sounds like you need to recalibrate your pressure transducer to give you the correct...
from the Curious department...
Temp Instrumentation 150 Yrs Ago
Topic: Application Questions and Problems
Posted by Grishma on 14 October, 2007 - 8:36 pm
How precise was temp instrumentation 150 yrs ago?
from the Automation List department...
Dialogic Telephony Card Issues with SCADA Alarms
Topic: Human-Machine Interface and SCADA.
Originally posted by Brian E Boothe on 10 October, 2007 - 10:49 pm
New Dialogic card version kills the dial tone on the phone line and it won't dial out. Has anyone
experienced any issues such as this?
New Replies:
By Nathan Boeger on 14 October, 2007 - 8:33 pm -
Brian, I got all excited when you mentioned Dialogic and RSView and Messanger - then realized that...
from the decimals nightmare department...
Float type data transmition
Topic: Continuous process industries, DCS questions.
Posted by Manuel Garcia on 14 October, 2007 - 8:32 pm
Float type data is not receiving equal as its origin.
from the Automation List department...
GE gas turbine parameters fluctuations
Topic: Application Questions and Problems
Posted by B.E on 14 October, 2007 - 8:31 pm
GE gas turbine parameters fluctuations
from the stymied department...
factorylink webclient on win xp sp2
Topic: Human-Machine Interface and SCADA.
Posted by DF on 14 October, 2007 - 8:31 pm
Webclient vanishes with no errors
from the Automation List department...
transformer parallel operation
Topic: Engineering and workplace issues.
Originally posted by Krishna on 25 August, 2007 - 11:20 am
Is it mandatory to have same X/R ratio of the transformers meant for parallel operation apart from same %impedance, voltage ratio and vector group?
New Replies:
By Kdx on 14 October, 2007 - 8:30 pm -
Hey ive been reading this forum and i have this problem. There are two transformers that i want to...
from the Automation List department...
Getting Started With RSView
Topic: Human-Machine Interface and SCADA.
Originally posted by SmallHydroGuy on 19 September, 2007 - 12:46 pm
I'm having trouble establishing comms between RSView and an SLC 5/03
New Replies:
By dan on 14 October, 2007 - 8:29 pm -
Kevin, Does the Panelview appear in RSLinx? If not, maybe it's communication settings don't match....
By Alan Hartwell on 14 October, 2007 - 8:17 pm -
I'm not an expert on RSView, but it looks like a conflict between Linx set up as DF1, and RSView...
By Helping Hand on 14 October, 2007 - 8:16 pm -
A SLC-503 has two communication channels. Channel 0 utilizes RS-232 and the DF1/ASCII protocol for...
By Bob Peterson on 14 October, 2007 - 7:25 pm -
Try setting it up as OPC instead. I have not had a lot of luck with the direct drivers....
By Nathan Boeger on 14 October, 2007 - 6:30 pm -
Kevin, Sorry, it's been too many years since I've used RSView. As I recall getting the connection...
from the ICA department...
Standalone FCS by Yokogawa
Topic: Continuous process industries, DCS questions.
Originally posted by Hamid on 4 October, 2007 - 8:16 pm
Is it possible to have standalone FCS by Yokogawa?
New Replies:
By sreeraj on 14 October, 2007 - 8:28 pm -
Better to ask your vendors to supply same plcs on all packages. And get it communicated to Cs3000...
from the Applied Kibology department...
Service Monitors
Topic: Communications systems and equipment.
Originally posted by Jeff on 7 May, 2003 - 5:20 pm
Looking for Suggestions on some radio Test equipment.
New Replies:
By Evan Pallesen on 14 October, 2007 - 8:27 pm -
I have been a radio and general electronics tech all my life, with only about three years in...
from the Automation List department...
Question about using TDR
Topic: Communications systems and equipment.
Originally posted by Frankis on 2 October, 2007 - 11:21 pm
Apply TDR on Modbus+ network.
New Replies:
By ROD on 14 October, 2007 - 8:21 pm -
Using a TDR on a MB+ network will be the very last step. 99% out of all problems can be solved with...
from the Electrical department...
How to connect Yokogawa power meter to Computer.
Topic: Information resources, documentation.
Posted by Abhay on 14 October, 2007 - 8:20 pm
I have Yokogawa WT230 Power meter with RS232 port for communication (D25 type). On the computer side we have 9pin COM port. How to let these two devices communicate?
from the Automation List department...
Suggested Flow Meters
Topic: Engineering and workplace issues.
Originally posted by Robert Bass on 2 October, 2007 - 2:07 am
In need of a air mass flow meter and a flow meter for diesel.
New Replies:
By Rohit Chandak on 14 October, 2007 - 8:19 pm -
I treat you, Mr. David Spitzer & Mr. Jesse Yoder as Flow Measurement Guru...if Corporate...
from the Automation department...
I/O addressing
Topic: PLCs and related questions.
Posted by SANDY GORDON on 14 October, 2007 - 8:18 pm
S-7 PLC confusion...
from the INSTRUMENTATION department...
Auto Dosing System
Topic: Continuous process industries, DCS questions.
Posted by kumar on 14 October, 2007 - 8:14 pm
I need the automatic ph dosing system. i want to maintain the ph of 10 of neutral solution (ph 7)by adding caustic solution...
from the control department...
4 wire vs. 3 wire RTD
Topic: Sensor technologies.
Originally posted by KAKIL on 3 October, 2007 - 12:00 am
What is the difference between 4 wire RTD and 3 wire RTD?
New Replies:
By DF on 14 October, 2007 - 8:13 pm -
Wont work I dont think. The way I understand it is that the "third" wire is a...
By ubtrefkou on 14 October, 2007 - 8:12 pm -
In answer to Dav: You can not do it that easy. I can send you a page with diagrams to show you ...
By Steve Yates on 14 October, 2007 - 6:30 pm -
Unless the application needs the accuracy that a 4 wire device can give you, I would just not use...
from the Automation List department...
Accuracy Class
Topic: Application Questions and Problems
Originally posted by Anonymous on 11 October, 2007 - 12:09 am
What is the meaning of accuracy class?
New Replies:
By Phil Corso, PE on 14 October, 2007 - 8:11 pm -
Responding to Anonymous' 11-Oct (00:09) question... If you are asking about Accuracy Class as...
By Carmel on 14 October, 2007 - 6:26 pm -
The class devisions are the error limits as a % of full scale deflection. DIN 16 005 Class 1.0...
from the Automation List department...
globe valve
Topic: Information resources, documentation.
Originally posted by Marzie on 6 October, 2007 - 9:32 am
replacement for a Raimondi globe valve
New Replies:
By sathish on 14 October, 2007 - 8:01 pm -
ARCA is manufacturing globe type valve...
from the Automation List department...
Latest JimPinto.com eNews - on the web
Topic: Industry news stories.
Posted by Jim Pinto on 14 October, 2007 - 7:50 pm
The latest issue of JimPinto.com eNews 12 Oct. 2007 is on the web...
from the Instrumentation department...
Line monitored input for ESD valves
Topic: Application Questions and Problems
Originally posted by instruguy on 11 October, 2007 - 1:04 am
Line monitored input for ESD
New Replies:
By A.K.Hait on 14 October, 2007 - 7:44 pm -
1st of all there is no need for line monitoring. Why ESD valve limit switches will require line...
By DaveMH on 14 October, 2007 - 7:44 pm -
>1. What is meant by monitored inputs? >How are they defined? Monitored inputs are...
By S Radhakrishnan on 14 October, 2007 - 7:43 pm -
There are four possible conditions associated with a filed contact: * Open contact * Closed...
from the Power Plant Department department...
Is MARK VIe migration a MUST for water injection on a GE Frame 7?
Topic: Engineering and workplace issues.
Originally posted by John Sweetwater on 9 October, 2007 - 1:50 pm
Is MARK VIe migration from MARK IV a MUST for water injection on a GE Frame 7?
New Replies:
By Bob Johnston on 14 October, 2007 - 7:42 pm -
I wouldn't have thought so John. I've never done water injection on a 7 as I'm mainly 60Hz. For a 5...
from the Maintenance department...
R,S,T computer display
Topic: Human-Machine Interface and SCADA.
Originally posted by Ritesh on 11 October, 2007 - 1:14 am
R,S,T core display in MarkV TMR system.
New Replies:
By Bob Johnston on 14 October, 2007 - 7:41 pm -
Are you really sure that R,S & T are powered up ? You will get comms with only <C>...
By CSA on 14 October, 2007 - 6:26 pm -
Do you mean the LCD displays on the LCC/SLCC cards are indicating nothing? They should be...
from the tracking department...
Gasoline truck tracking
Topic: Communications systems and equipment.
Originally posted by louis on 26 July, 2007 - 11:16 pm
I'm looking for a system to measure level or flow rate of diesel or gasoline tankers by means of GPS...
New Replies:
By Rohit Chandak on 14 October, 2007 - 7:40 pm -
There are electronic modules integrated with flow meter to let you have the information from flow...
from the Automation department...
Polling time
Topic: PLCs and related questions.
Originally posted by adello on 11 October, 2007 - 12:53 am
Polling with large SCADA with 33 PLCs/DCSs
New Replies:
By Anonymous on 14 October, 2007 - 7:38 pm -
Dear, Problem does not exist in Number of Front End Servers. The Inter-networking may raise...
from the Automation List department...
Info about contactors
Topic: Engineering and workplace issues.
Originally posted by ste on 8 October, 2007 - 7:20 pm
confusion about contactor function...
New Replies:
By Tom Chubb on 14 October, 2007 - 7:37 pm -
Contactors are essentially heavy duty relays and are often used for switching motors. -- Tom...
By Michael Griffin on 14 October, 2007 - 5:57 pm -
A contactor is a large relay. They are usually single throw with three or four poles. They may have...
from the Automation List department...
Connexium Managed Switch With Vijeo Citect
Topic: Communications systems and equipment.
Originally posted by Anant on 26 September, 2007 - 11:33 pm
Managed Switch Diagnostics on Vijeo Citect SCADA
New Replies:
By gik on 14 October, 2007 - 7:26 pm -
Use Microsoft Web Browser control "C:\WINDOWS\system32\shdocvw.dll" to display diagnostic...
from the automation department...
communication detween vfd's & plc
Topic: Human-Machine Interface and SCADA.
Posted by ramu on 14 October, 2007 - 7:26 pm
communicati0n problem
from the elactrical department...
1 to 150 r.p.m speed controle with dc motors
Topic: Engineering and workplace issues.
Originally posted by JANARDHAN on 9 October, 2007 - 11:51 am
A dc motor of torque 1kg-cm is to be rotated from 1 to 150 r.p.m based on the speed mentioned in that range
New Replies:
By Michael Griffin on 14 October, 2007 - 7:22 pm -
In reply to Curt Wuollet: He wants to be able to control the speed in 1 rpm increments between 1...
By Anonymous on 14 October, 2007 - 6:23 pm -
Hi, Regardless of the method used to obtain the speed some measure of tolerance, velocity ripple,...
By Michael Griffin on 14 October, 2007 - 5:59 pm -
You want a servo drive with a gear box. The servo drive and servo motor will give you a controlled...
from the Automation List department...
Level Transmitter for automatic tank draining
Topic: Sensor technologies.
Originally posted by Jay M. on 25 August, 2007 - 12:21 am
Looking to automatically drain a tank that currently does not fully drain. Need Level transmitter, plc, and pump.
New Replies:
By Walt Boyes on 14 October, 2007 - 7:21 pm -
Fact is, while I do like ultrasonic level, it is generally a little expensive for this type of...
from the Automation List department...
Base Temp & Pressure
Topic: Application Questions and Problems
Posted by Anonymous on 14 October, 2007 - 6:29 pm
what should be the base temperature & pressure for calculating the sizing of orifice plates for liquid & gas applications?
from the Automation List department...
TSXPCX 1031 with TSX Premium
Topic: PLCs and related questions.
Originally posted by Anonymous on 27 June, 2007 - 11:19 pm
We have some problem in our Extension PLC modules...
New Replies:
By sonytau on 14 October, 2007 - 6:28 pm -
This Instruction ...
from the instrumentation & control department...
Comunication between two PLCs of different manufacturers
Topic: Communications systems and equipment.
Originally posted by sarfraj patel on 30 August, 2007 - 8:09 pm
Communication between two PLCs: GE Fanuc & Allen-Bradley using Modbus RTU protocol.
New Replies:
By G MURALI on 14 October, 2007 - 6:24 pm -
you need to set same slave id what u used in fanuc ladder logic, communication parameters in slave...
from the Operation department...
Off-line water washing
Topic: Engineering and workplace issues.
Originally posted by Swagata Sarkar on 11 February, 2007 - 12:26 pm
Is DI water good for compressor wash?
New Replies:
By sd on 14 October, 2007 - 6:23 pm -
well actually the washing skid has 2 water temperature selector namely cold and hot. from the ...
from the Automation List department...
modbus newbie
Topic: Communications systems and equipment.
Originally posted by t milam on 19 February, 2006 - 2:19 pm
how to set up communications between a Caterpillar generator panel (EMCP 3.2) and a plc with modbus
New Replies:
By Doyle Taylor on 14 October, 2007 - 6:22 pm -
The CCM Module is traditionally about $1500 USD, but since it is being discontinued the CAT Dealers...
By Doyle Taylor on 14 October, 2007 - 6:13 pm -
The CCM Module will not work with the EMCP 3 series. Since they implemented Modbus in this panel,...
By Doyle Taylor on 14 October, 2007 - 6:12 pm -
The CAT EMCP 3.2 has a Modbus output, but I have heard many complaints about the implementation by...
from the Automation List department...
Embedded systems courses in Mumbai, India
Topic: Information resources, documentation.
Originally posted by bhagyashri on 15 July, 2005 - 8:18 pm
can anybody give me info about the best institute which provides embedded software training in mumbai (its contact details, if possible)?
New Replies:
By Reshma Mankar on 14 October, 2007 - 6:21 pm -
visit http://www.hitechend.in for further details. do visit our center before taking any decison...
By Jaince Pinto on 14 October, 2007 - 5:51 pm -
Hi, well we are from the batch which shifted to HTE. we got excellent training and support from...
from the marketing department...
CPU with yasakawa IOs
Topic: PLCs and related questions.
Posted by tusharjani on 14 October, 2007 - 6:20 pm
Can we use CPU434 of quantus and retain the I/Os of yasakawa PLC R-84H?
from the Automation List department...
single input analog to digital DAQ
Topic: Engineering and workplace issues.
Posted by Mcvils on 14 October, 2007 - 6:19 pm
need a diagram or a product that has only one analog input, convert it to digital and has a pc interface...
from the electrical department...
Load sharing in alternators
Topic: Engineering and workplace issues.
Originally posted by "anonymous" on 11 October, 2007 - 12:25 am
Question regarding load sharing
New Replies:
By CSA on 14 October, 2007 - 6:16 pm -
Alternators don't share load. The prime movers of the alternators have governors that can be...
from the Automation List department...
Adjustment
Topic: Engineering and workplace issues.
Originally posted by Luigi on 4 October, 2007 - 8:58 pm
Balancing load in parallel electric generator
New Replies:
By luigi on 14 October, 2007 - 6:15 pm -
Thanks. I have another qustion. I'm noy vey well versed in electrical power engineering so I could...
Topic: Continuous process industries, DCS questions.
Posted by arch15 on 14 October, 2007 - 6:10 pm
Orifice Plate- straight run requirements w.r.t beta ratio
from the Mark V department...
DCC I/O card Obj #4 and obj#13 got reset
Topic: Application Questions and Problems
Originally posted by Viswa on 19 May, 2007 - 3:09 pm
We have a problem with one of our mark V panel with all C processor inputs going to alarm state
New Replies:
By CSA on 14 October, 2007 - 6:00 pm -
This is good news, and, thanks for the feedback. How will you get new IOMA PROMs? The AC...
from the Not as advertised department...
Wago Scan Time Improvements
Topic: PLCs and related questions.
Originally posted by Bruce Thompson on 3 October, 2007 - 10:49 pm
Total scan time needs to be improved.
New Replies:
By John Ditter on 14 October, 2007 - 5:54 pm -
Are you using the CoDeSys Task Configuration? If not, create a 5ms cyclic task with a priority of...
from the Automation List department...
Teco Variable Speed Drives
Topic: Motion control, servos, steppers, etc.
Originally posted by Dave Smith on 8 October, 2007 - 9:56 am
Feedback on Teco AC Variable Speed Drives
New Replies:
By James Ingraham on 14 October, 2007 - 5:53 pm -
From William Sturm: "It appears to me that the Teco drives are relabeled Yaskawa drives. If...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!