Saturday, October 27, 2007
from the Automation List department...
Download Error in Concept
Topic: Software, including programming, OS issues, etc.
Originally posted by Damon Belfield on 27 October, 2007 - 1:17 am
Concept Error - User not logged in (OL9-1600)
New Replies:
By Rahul Mohite on 27 October, 2007 - 5:55 pm -
This could be the problem of your Modbus cable. Please change your Modbus cable and proceed. pl...
from the Automation List department...
Why is it 4-20
Topic: Continuous process industries, DCS questions.
Originally posted by Rafa on 16 October, 2007 - 11:28 pm
Can someone explain the whole 4-20mA thing to me?
New Replies:
By Curt Wuollet on 27 October, 2007 - 4:59 pm -
I've been working with a large UV ink polymerization system that uses saturable reactors to control...
By Michael Batchelor on 27 October, 2007 - 1:09 am -
Wow, this brings back some memories. I can't even remember the last time I saw a mag-amp. I'm sure...
from the Automation List department...
Link twido PLC with Easy touch touchscreen
Topic: Communications systems and equipment.
Originally posted by Jose on 27 October, 2007 - 11:57 am
Link twido PLC with Easy touch touchscreen
New Replies:
By Dweebyone on 27 October, 2007 - 4:56 pm -
~Is that all! A little more info would be useful! Method of coms? Cabling distance? Surely...
from the Automation List department...
Microcontroller based digital DC motor speed control
Topic: Motion control, servos, steppers, etc.
Originally posted by kasturi on 27 October, 2007 - 1:47 am
Block diagram and how to use microcontroller
New Replies:
By Curt Wuollet on 27 October, 2007 - 4:36 pm -
Isn't that what you were supposed to have learned? I would expect you have books to read. ...
from the Automation List department...
Omron CPM1A Connector
Topic: PLCs and related questions.
Posted by Thomas on 27 October, 2007 - 4:36 pm
Can anyone tell me where I can obtain a Omron CPM1 Connector?
from the serious department...
RS-485 Interface with Modicon PLC
Topic: PLCs and related questions.
Originally posted by SANDEEP MENON on 23 October, 2007 - 12:20 am
I have to interface Caterpillar engine, which is RS-485 standard, with my Modicon Premium PLCs.
New Replies:
By Curt Wuollet on 27 October, 2007 - 3:39 pm -
You do need a ground reference though (or isolation) to keep the input pins within their common...
By David Adams on 27 October, 2007 - 2:07 am -
RS 485 2 wire does not utilize the ground for a signal common. The signal is between the Rx-/Tx-...
from the Help!!!!! department...
A-B SLC 150
Topic: PLCs and related questions.
Originally posted by control_logic on 18 June, 2007 - 1:34 pm
SLC 150 command set
New Replies:
By Curt Wuollet on 27 October, 2007 - 3:36 pm -
I would check the voltage at the terminals, it might not be high enough. Also, as these units age...
By John Kitz on 27 October, 2007 - 2:26 am -
I hope you will help a dummy. When I retired, I was able to get an SLC-150, AB 1745-LP153, and now...
from the electrical department...
Fuse
Topic: Engineering and workplace issues.
Originally posted by naresh on 27 October, 2007 - 1:02 am
How to decide and calculate fuse sizing?
New Replies:
By Curt Wuollet on 27 October, 2007 - 3:32 pm -
For that matter, there is a great deal more here that should be done by a competent person. Scares...
By Trevor Ousey \(List Bigpond\) on 27 October, 2007 - 12:01 pm -
You should be more specific. What are you using the fuse for? Generally the fuse/circuit breaker...
from the Automation List department...
MODBUS and ControlLogix
Topic: PLCs and related questions.
Originally posted by Jaime Marcelo Cedeño Pozo on 27 October, 2007 - 2:28 am
I need to communicate to a ControlLogix CPU with a MODBUS Plus Network.
New Replies:
By Bob Peterson on 27 October, 2007 - 12:14 pm -
I think prosoft has a module you could use....
from the Gas Turbines department...
Turbine Synchronization
Topic: Engineering and workplace issues.
Originally posted by Mambo on 24 October, 2007 - 12:30 am
Generator voltage blinks on <I> Dos Interface when ready to synchronize in Auto mode.
New Replies:
By CSA on 27 October, 2007 - 12:09 pm -
Well, this is very interesting. You have been able to synchronize the unit. How were you able to...
By Mambo on 27 October, 2007 - 1:52 am -
Dear CSA, Thank you and everybody for the reply. All the card ribbon cables were checked for...
from the Automation List department...
Modbus integrator
Topic: Communications systems and equipment.
Originally posted by Shyam on 27 October, 2007 - 1:07 am
J-bus to Modbus communication
New Replies:
By Jose Thomas on 27 October, 2007 - 12:02 pm -
My understanding is that J-Bus and Modbus has the same set of function codes and frame formats,...
from the Automation List department...
mark V control system
Topic: Continuous process industries, DCS questions.
Posted by spkam on 27 October, 2007 - 11:59 am
Rebooting problem with mark v computers during lightning
from the Ge Fanuc department...
Cimplicity HMI problem... Urgent...
Topic: Human-Machine Interface and SCADA.
Posted by alansal on 27 October, 2007 - 11:58 am
Sql Server of my cimplicity hmi is disappeared somehow for this reason i can't save the trends!
from the Technical Department department...
Belt conveyor calculation
Topic: Engineering and workplace issues.
Originally posted by Hung on 19 October, 2007 - 5:03 pm
Please can someone tell me how to caculate motor power?
New Replies:
By Phil Corso, PE on 27 October, 2007 - 11:58 am -
Responding to Hung's 19-Oct (17:03) query... if you are still seeking a solution, I have a Nomogram...
from the Automation List department...
Simatic WinCC alarms
Topic: Human-Machine Interface and SCADA.
Originally posted by binod on 25 September, 2007 - 10:50 pm
I want to generate audible alarm in my WinCC
New Replies:
By Ronald on 27 October, 2007 - 11:56 am -
Since V6.0 WinCC offers a so named "Horn editor" This configuration tool allows you to...
from the Automation List department...
Voltage Drop in Instrumentation Cables
Topic: Engineering and workplace issues.
Originally posted by Sakthi on 24 July, 2007 - 4:03 pm
Please let me know how to calculate the voltage drop of 1P X 1.5sqmm Instrumentation cable (BS 5308 Part 2, Type 2) connected between PLC & PT (4-20mA O/P) placed 1500m apart.
New Replies:
By xxx on 27 October, 2007 - 11:55 am -
But for voltage drop, we need to have voltage available at transmitter end (+ve terminal). This...
from the Electrical department...
Best Power Management System?
Topic: Engineering and workplace issues.
Originally posted by Harry on 2 October, 2007 - 12:25 am
ABB 800 A, Siemens PCS 7, Rockwell Automation... which is best for power management system?
New Replies:
By Ronald on 27 October, 2007 - 11:54 am -
I would consider checking out SICAM http://www.siemens.com/sicam -R...
from the Automation List department...
liquid particle counter
Topic: Sensor technologies.
Posted by ronnie on 27 October, 2007 - 11:46 am
which size is it counting?
from the Automation List department...
IGV basics
Topic: Continuous process industries, DCS questions.
Posted by prashant on 27 October, 2007 - 11:45 am
IGV Valves
from the gas turbine department...
DCC IO OBJ#1
Topic: Application Questions and Problems
Posted by KM on 27 October, 2007 - 2:28 am
The unit running Core <C> had alarm DCC IO OBJ#1 at DCC bar graph flash.
from the Automation List department...
Debugging in SIMATIC S7
Topic: PLCs and related questions.
Posted by k.zonouzi ahmad on 27 October, 2007 - 2:25 am
Debugging possibilities in other languages than SCL
from the humidity sensor department...
Relative humidity sensor
Topic: Sensor technologies.
Originally posted by sid on 25 October, 2007 - 11:28 pm
I need to select a relative humidity sensor for measuring humidity prior to welding.
New Replies:
By syurish on 27 October, 2007 - 2:24 am -
Please see the following link for technology review: ...
from the Automation List department...
Copy and paste to Excel
Topic: Application Questions and Problems
Originally posted by ahmad k.zonouzi on 22 October, 2007 - 4:40 pm
Copy and paste address field of a DB to an Excel file.
New Replies:
By k.zonouzi ahmad on 27 October, 2007 - 2:22 am -
Hi Luca Gallina, Thank you for the reply, I got my answer. But the site you mentioned was even...
from the Is Standard Upload possible? department...
IEC 61131-3 Standard Question
Topic: PLCs and related questions.
Originally posted by Netmatt on 25 October, 2007 - 10:43 pm
Is Standard Upload possible for IEC 61131-3 Compliant PLC Devices?
New Replies:
By Michael Griffin on 27 October, 2007 - 2:18 am -
IEC 61131-3 is a description of the programming language only. It doesn't deal with how to upload...
from the Instrumentation & Control department...
Honeywell TPS/TDC3000: Tapping Modbus Data
Topic: Communications systems and equipment.
Originally posted by Rahul P Sharma on 31 May, 2007 - 11:17 pm
Want to read data from a Modbus compatible unit using Honeywell's TPS system
New Replies:
By Troy Mcgill on 27 October, 2007 - 2:06 am -
Hello, Do you know where I can download the OP01501.pdf? Any help is appreciated. Thanks, ...
Topic: Motion control, servos, steppers, etc.
Originally posted by sarabjot singh manku on 25 October, 2007 - 10:40 pm
We are going to control the position and speed of a stepper motor using em 253 positioning module with Siemens S7 200 PLC (CPU 222, version - 02.01).
New Replies:
By Marc Sinclair on 27 October, 2007 - 2:03 am -
Hi, The EM 253 cannot drive a stepper directly, so stepper motor specificatins are no help...
from the Automation department...
Mid-size DCS
Topic: Continuous process industries, DCS questions.
Posted by F. Mielli on 27 October, 2007 - 2:02 am
DCS - Small and mid-size suppliers
from the Control room department...
DCS problem
Topic: Continuous process industries, DCS questions.
Posted by Highland on 27 October, 2007 - 2:02 am
DCS knowledge
from the Automation List department...
Intergraph Intools
Topic: Information resources, documentation.
Originally posted by mclee on 14 October, 2004 - 2:02 pm
Does anyone know where on the web I can find resources for learning Intools?
New Replies:
By Eduardo Viera on 27 October, 2007 - 1:59 am -
Dear Hadi, If you need help about Intools or any platform of Intergraph, please write to my...
from the Are there any decent ones anywhere??? department...
PL7 Pro guide for using bridging and FIP, etc.
Topic: PLCs and related questions.
Originally posted by Graeme Sayer on 19 October, 2007 - 1:13 am
I'd like to be able to assist vendors with setting up the PLCs
New Replies:
By Graeme on 27 October, 2007 - 1:54 am -
It's not a safety issue, as what I do doesn't interfere with the way the PLC controls machines. ...
from the Automation List department...
Simple AC drive motion control
Topic: Motion control, servos, steppers, etc.
Posted by Nik Avlogiaris on 27 October, 2007 - 1:54 am
Simple AC drive motion control for measuring cable wire length with accuracy
from the E&I department...
Yokogawa DCS
Topic: Communications systems and equipment.
Originally posted by Naeem Tahir on 25 October, 2007 - 12:58 am
RS-485 communication
New Replies:
By Jerry Miille on 27 October, 2007 - 1:51 am -
I do not fully understand your problem, but, please look at our products that can either transform...
By Professional on 27 October, 2007 - 1:17 am -
Mr. Naeem, You have purchased a Modbus communication package (ALR111, ALR121) for your Tullow...
By A.K.Hait on 27 October, 2007 - 1:04 am -
You need to configure the flow computer as Master and DCS & GAS Chromotograph as slaves. Give...
By dchartier on 27 October, 2007 - 12:59 am -
Hello Naeem; A Modbus network running on RS-485 is multidrop, so a master can access two slaves...
from the density of sludge in water flow department...
Density of sludge in water flow in pipeline
Topic: Sensor technologies.
Posted by WhitecraneH on 27 October, 2007 - 1:50 am
I would like to find a sensor to measure the density of sludge flowing in the pipe.
from the automatic control department...
Test and production separator
Topic: Continuous process industries, DCS questions.
Originally posted by mourad on 27 April, 2007 - 1:07 am
Flow variations for one well with two different separators
New Replies:
By James on 27 October, 2007 - 1:48 am -
Please tell me your test separator details for our checking....
from the GE Wonderful department...
MKV LTKALM1 Constant for TTIB1
Topic: Continuous process industries, DCS questions.
Posted by tgun on 27 October, 2007 - 1:45 am
Looking for the constant value for LTKALM1 on a GE Frame 7EA MKV.
from the Automation List department...
Current to Voltage Converter
Topic: Sensor technologies.
Originally posted by Yaser Khodabakhsh on 25 October, 2007 - 12:55 am
Current to Voltage Converter
New Replies:
By Curt Wuollet on 27 October, 2007 - 1:43 am -
You need a 1k ohm 1% resistor. It will be faster than anything in industrial control. Regards ...
By Issac Issachar on 27 October, 2007 - 1:26 am -
Use a 1,000 ohm resistor. Ohms Law: R = E/I R = 10.0V/0.010A = 1000 ohms Issac...
By KW on 27 October, 2007 - 12:54 am -
Use a 1000 Ohm resistor......
Topic: PLCs and related questions.
Originally posted by Aan on 25 October, 2007 - 12:19 am
Using more than one Prosoft MVI-46 MCM module for SLC-5 PLC
New Replies:
By CH on 27 October, 2007 - 1:43 am -
Easiest way is to call Prosoft, as I'm sure they have example ladder. To do it yourself, do...
By Eddie Willers on 27 October, 2007 - 1:40 am -
You can use as many MV46-MCM modules in a single SLC-500 1746-series chassis as you wish. They...
from the Object Table department...
Create object table in CimEdit Screen
Topic: Human-Machine Interface and SCADA.
Posted by rcborjas on 27 October, 2007 - 1:42 am
The best Active X control to create a table object
from the INQUIRY department...
RTOS TRAINING
Topic: Engineering and workplace issues.
Originally posted by ARUN on 25 June, 2006 - 2:41 pm
looking for short term RTOS training
New Replies:
By Pradeep on 27 October, 2007 - 1:38 am -
Let me know if you need training on embedded, ARM, VXworks, Threadx, USB, Ethernet (Drivers), etc....
from the Automation List department...
Multiple Screens Solution
Topic: Application Questions and Problems
Originally posted by Rene Venter on 23 October, 2007 - 12:51 am
I have an application where I am using a Siemens 315-2DP CPU to control 3 x machines. My client now wants a colour screen (plus/minus 6 inches) at each of the machines to display certain process values at each machine...
New Replies:
By Tony R. Gunderman on 27 October, 2007 - 1:32 am -
If you have just a single PLC, you may want to look at Maple Systems (http://www.maplesystems.com)....
By David Adams on 27 October, 2007 - 1:29 am -
Have you looked at Maple Systems?...
By deepak on 27 October, 2007 - 12:50 am -
Hello, You can go for HAKKO Touch Screen. This is the cheapest solution. You can go for...
from the Automation List department...
JimPinto.com eNews on the web
Topic: The Business of Automation and Control
Posted by Jim Pinto on 27 October, 2007 - 1:31 am
The latest JimPinto.com - Connections for Growth & Success(TM) eNews No. 240 - 25 October 2007 - is on the web...
from the engineering department...
Function of Turbine – Compressor set
Topic: Application Questions and Problems
Originally posted by H.P on 19 October, 2007 - 3:40 pm
Function of Turbine – Compressor set
New Replies:
By S. Radhakrishnan on 27 October, 2007 - 1:30 am -
Droop control applies only to generator drives. Mechanical drive gas turbines operate on...
By controlmech on 27 October, 2007 - 1:18 am -
Isoc and droop control modes are only relevent when controlling a generator. The control modes have...
from the Automation List department...
PCI to ISA adapter
Topic: Computers in manufacturing; also hardware discussion.
Originally posted by Scott on 9 September, 2002 - 4:13 pm
I have a need to install an old ISA card into a PC with PCI cards...
New Replies:
By ds on 27 October, 2007 - 1:26 am -
Thanks for the link! Hope it works....
from the Automation List department...
Automation/PLCs and business organization
Topic: The Business of Automation and Control
Originally posted by Piotr Kowalski on 25 October, 2007 - 1:00 am
I am interested where the automation specialists are located in the organizational structure of the enterprise (especially in the food industry)...
New Replies:
By Nik Kinze on 27 October, 2007 - 1:25 am -
In the past the automation gurus have usually been in the Engineering departments. Around 2000 or...
By Rana Muhammad Imran on 27 October, 2007 - 1:09 am -
Dear sir, In most organizations, there is an Electrical & Instrumentation department...
from the Automation List department...
Modsoft Communication Error
Topic: Software, including programming, OS issues, etc.
Posted by Damon Belfield on 27 October, 2007 - 1:20 am
Modsoft connection error when directly connected to PLC
from the Automation List department...
Linklater Lead Oxide Mill
Topic: Engineering and workplace issues.
Posted by steven crowther on 27 October, 2007 - 1:19 am
Drawings for Linklater Mill
from the Installation department...
Rice polishing machine monitoring
Topic: Sensor technologies.
Posted by vijayneethiraj on 27 October, 2007 - 1:05 am
I am doing a project for rice polishing machine, in that I want to display the amount of paddy or rice flowing through the machine...
from the Automation List department...
Active power transducer required
Topic: Sensor technologies.
Originally posted by sandeep on 19 October, 2007 - 3:38 pm
Active power transducer required
New Replies:
By SEDAT on 27 October, 2007 - 1:01 am -
Visit http://weigel.com.de The model is "dgw2.2" or "vgw2.2", it depends on...
from the Automation List department...
WinCC Toggle
Topic: Human-Machine Interface and SCADA.
Originally posted by Khaled Ezzat on 20 October, 2007 - 11:16 am
Want to assign tag to make toggle
New Replies:
By sergey on 27 October, 2007 - 12:53 am -
The same things only on Visual Basic, but for me C++ is more understandable....
from the Automation List department...
Radar sensor for level measuring application
Topic: Sensor technologies.
Posted by Tran on 27 October, 2007 - 12:52 am
I need an advice on choosing a cost effective radar sensor
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.