Tuesday, October 30, 2007
from the Any SMC 3010/4040 gurus? department...
Yaskawa SMC series Motion Controllers/PLC interface
Topic: Motion control, servos, steppers, etc.
Posted by c.m. on 30 October, 2007 - 11:47 pm
Anybody interfaced an L35E with a Yaskawa 4040?
from the Automation List department...
Common mode voltages in analog and digital I/O modules
Topic: Engineering and workplace issues.
Posted by Self on 30 October, 2007 - 11:24 pm
I want the significance of the lines written in a specification given for analog and digital I/O card signal processing.
from the Automation List department...
Tutorial or book
Topic: Computers in manufacturing; also hardware discussion.
Originally posted by Beny Rey on 30 October, 2007 - 1:20 am
I am looking for tutorial, templates, books, etc. for learning AB PanelView PLC
integration...
New Replies:
By Jose Rivera on 30 October, 2007 - 11:24 pm -
First, you should know the model of the panelview and the model or series of the PLC to be...
from the Automation List department...
Current transformer in series
Topic: Engineering and workplace issues.
Originally posted by Sukumar on 20 October, 2007 - 11:14 am
Two CT secondaries, in series.
New Replies:
By Carlo on 30 October, 2007 - 11:21 pm -
Hi! I have a similar question. I was browsing the net for information on having a series...
from the Automation List department...
Message Time Outs on Data Highway
Topic: Communications systems and equipment.
Posted by JOSEPHJOEYSHOUSE on 30 October, 2007 - 11:19 pm
We are experiencing a message that reads message time outs on the data highway
from the Some help on the terms department...
OPC Specifications License
Topic: Software, including programming, OS issues, etc.
Originally posted by Peter on 30 October, 2007 - 1:31 am
I want to know some details for the legal terms of the new OPC UA specifications.
New Replies:
By Thomas J. Burke on 30 October, 2007 - 11:18 pm -
As the president and executive director of the OPC Foundation, we're currently working on defining...
By Nathan Boeger on 30 October, 2007 - 11:04 pm -
That's a really great question! In short, I don't know and would recommend that you ask here: ...
from the Automation List department...
Stepper motor controller
Topic: Motion control, servos, steppers, etc.
Posted by AcoidanBM on 30 October, 2007 - 11:15 pm
Design of a stepper motor controller using Simulink
from the application department...
3 phase motor and MicroLogix PLC
Topic: PLCs and related questions.
Posted by edward on 30 October, 2007 - 11:14 pm
Connecting a 3 phase motor to MicroLogix 1500 PLC
from the Automation List department...
Measuring rotor position by using quad encoder
Topic: Motion control, servos, steppers, etc.
Posted by ramesh on 30 October, 2007 - 11:10 pm
I am doing a project on designing an AC drive for 30hp induction motor...
from the SXD department...
Citect SCADA
Topic: Software, including programming, OS issues, etc.
Originally posted by schineider on 27 September, 2007 - 11:54 pm
Modnet protocol details in Citect SCADA ver. 6.1
New Replies:
By Mathieu D on 30 October, 2007 - 11:09 pm -
Hello, Excuse my bad english but I'm French. I want to use Citect SCADA and after Vijeo Citect)...
from the Automation List department...
Communications master - slave
Topic: Communications systems and equipment.
Posted by Anonymous on 30 October, 2007 - 11:08 pm
Communication between a Wago PLC Modbus master and slave devices through RS485 serial interface module 750-653/003-000.
from the Automation List department...
Debugging in SIMATIC S7
Topic: PLCs and related questions.
Originally posted by k.zonouzi ahmad on 27 October, 2007 - 2:25 am
Debugging possibilities in other languages than SCL
New Replies:
By Ganesh V Iyer on 30 October, 2007 - 11:01 pm -
Hi, You are right my friend. Only in STL, SCl and above languages step by step debugging is...
By k.zonouzi ahmad on 30 October, 2007 - 1:27 am -
Hi, I have found that in STL it is possible, through going online and using the debugging...
from the Automation List department...
MODBUS and ControlLogix
Topic: PLCs and related questions.
Originally posted by Jaime Marcelo Cedeño Pozo on 27 October, 2007 - 2:28 am
I need to communicate to a ControlLogix CPU with a MODBUS Plus Network.
New Replies:
By Michael E. Crossman on 30 October, 2007 - 1:37 am -
Modbus PLUS is very different and separate from Modbus. It is a proprietary protocol. The other...
By Jason L. Block on 30 October, 2007 - 1:24 am -
Hi Jaime, If it is truly Modbus Plus you need to convert to, we provide gateway solutions that...
By Darrin Hansen on 30 October, 2007 - 1:19 am -
These are all good responses, but the OP needs to connect to MB+, which is different from regular...
Topic: Engineering and workplace issues.
Posted by Dang Quang Hung on 30 October, 2007 - 1:37 am
high overshoot when synchronizing the generator to grid.
from the Automation List department...
DeltaV Maintenance and Backups
Topic: Application Questions and Problems
Originally posted by Ricardo Llavina on 13 September, 2007 - 11:06 pm
Has anyone found a way to automate the DeltaV database cleanup, either the regular or the extended procedure? Also, I am looking for options to backup a DeltaV system.
New Replies:
By Jason Villamil on 30 October, 2007 - 1:35 am -
Ricardo, On second look, there is a command-line way to perform a database clean in DeltaV...
By Somnath on 30 October, 2007 - 1:05 am -
Ricardo, Which version of DeltaV you are using? From 9.3 onwards, DeltaV database manager has...
from the Bharat PLC department...
Bharat Control PLC
Topic: PLCs and related questions.
Posted by jay on 30 October, 2007 - 1:34 am
Bharat Control PLC
from the Automation List department...
Torque mode or dancer mode?
Topic: Continuous process industries, DCS questions.
Posted by Anish Kumar on 30 October, 2007 - 1:32 am
Torque mode or dancer mode?
from the Automation List department...
Allen-Bradley Ethernet and Ethernet/IP specification
Topic: Communications systems and equipment.
Originally posted by Webber on 20 October, 2007 - 11:05 am
AB Ethernet and Ethernet/IP specification
New Replies:
By Mark on 30 October, 2007 - 1:29 am -
Hello, The Ethernet/IP spec is maintained by http://www.odva.org. They are the copyright...
from the Automation List department...
Citect to EGX200 to Sepam 40
Topic: PLCs and related questions.
Originally posted by twtysvn on 19 October, 2007 - 3:45 pm
Address field
New Replies:
By Albert Olive on 30 October, 2007 - 1:27 am -
- Firstly you need to select inside the Express Communication Wizard Menu the Disc IO Device (not...
from the Automation List department...
TDC 3000 alarms
Topic: Software, including programming, OS issues, etc.
Originally posted by Imen on 2 October, 2007 - 10:40 pm
I would like to develop a program which allows to collect alarms from Honeywell TDC 3000.
New Replies:
By john on 30 October, 2007 - 1:22 am -
This has been done many times before, and depends on what hardware you have available, e.g. AM, HM,...
from the power supply department...
4-20mA schematic
Topic: PLCs and related questions.
Originally posted by Morteza on 28 October, 2007 - 1:14 pm
4-20mA
New Replies:
By Steve Yates on 30 October, 2007 - 1:19 am -
I'm not sure what industry you are in but back in the days when the MTL Application Notes were...
from the Automation List department...
Download Error in Concept
Topic: Software, including programming, OS issues, etc.
Originally posted by Damon Belfield on 27 October, 2007 - 1:17 am
Concept Error - User not logged in (OL9-1600)
New Replies:
By Damon Belfield on 30 October, 2007 - 1:12 am -
Problem solved, turned out to be a faulty programming lead. Thanks. Damon...
from the Automation List department...
Simple AC drive motion control
Topic: Motion control, servos, steppers, etc.
Originally posted by Nik Avlogiaris on 27 October, 2007 - 1:54 am
Simple AC drive motion control for measuring cable wire length with accuracy
New Replies:
By B on 30 October, 2007 - 1:11 am -
Nik, Good thing you use the word intend, that generally means you haven't bought anything yet. ...
from the Profibus department...
ABB to Siemens Profibus DP
Topic: Computers in manufacturing; also hardware discussion.
Posted by MKunold on 30 October, 2007 - 1:10 am
I am looking for a GSD file, CI541 to S7 315 F.
from the Control systems department...
ABB Solutions
Topic: Engineering and workplace issues.
Originally posted by Mazdex on 28 September, 2007 - 11:12 pm
ABB connectivity solutions
New Replies:
By Ravi on 30 October, 2007 - 1:08 am -
Hi, Are you looking for SAP/MAXIMO? If yes, then ABB provides 800xA connectivity to enterprise...
from the Automation List department...
Modsoft Communication Error
Topic: Software, including programming, OS issues, etc.
Originally posted by Damon Belfield on 27 October, 2007 - 1:20 am
Modsoft connection error when directly connected to PLC
New Replies:
By Damon Belfield on 30 October, 2007 - 1:07 am -
Problem solved, turned out to be a faulty programming lead. Thanks. Damon...
from the Loop Check department...
P+F splitter and Emerson AMS communication
Topic: Human-Machine Interface and SCADA.
Posted by Gray on 30 October, 2007 - 1:05 am
Losing communication on Channel 2 of AI splitter KFD2-STC4-Ex12O.
from the Automation List department...
Looking for Blind Flange
Topic: Continuous process industries, DCS questions.
Originally posted by Sandy on 24 March, 2004 - 5:56 pm
Please advise where I can find the below item
Blind flange 3” 300” A-350 F2
New Replies:
By nancy on 30 October, 2007 - 1:02 am -
We are Beicheng Flange Co., Ltd., one of the leading flange manufacturers in Dingxiang. We are...
from the Purchasing department...
Mark-V speedtronic cards
Topic: Engineering and workplace issues.
Posted by irfi on 30 October, 2007 - 1:00 am
What's the importance of revision level when purchasing Speedtronic cards?
from the electrical department...
Fuse
Topic: Engineering and workplace issues.
Originally posted by naresh on 27 October, 2007 - 1:02 am
How to decide and calculate fuse sizing?
New Replies:
By naresh on 30 October, 2007 - 1:00 am -
My purpose is to protect the 25 kva transformer. Its ratings are 480V/208V, 3ph, delta star. I need...
from the Production Dept department...
MicroMotion shows negative value
Topic: Continuous process industries, DCS questions.
Originally posted by NB on 28 October, 2007 - 1:15 pm
MicroMotion shows negative value
New Replies:
By NB on 30 October, 2007 - 12:58 am -
Hi, Dilesh I am sure the line opened, we have MM at gathering station from this well. Need...
from the Automation List department...
L86S Auto Sync lock out alarm Problem
Topic: Continuous process industries, DCS questions.
Originally posted by Lookose on 28 October, 2007 - 8:32 pm
whenever we synchronise the machine...
New Replies:
By CSA on 30 October, 2007 - 12:57 am -
Does the unit synchronize and then the auto-sych lockout is annunciated, or is it not possible to...
Topic: Communications systems and equipment.
Originally posted by John Carvajal on 25 September, 2007 - 11:34 pm
When I executed this command: "modpoll -m enc -t 4:float 10.128.16.72" an error message appears...
New Replies:
By Anonymous on 30 October, 2007 - 12:55 am -
Which ways are you trying to poll? From an ethernet driver through the gateway to a serial device...
from the Automation List department...
Embedded systems courses in Mumbai, India
Topic: Information resources, documentation.
Originally posted by bhagyashri on 15 July, 2005 - 8:18 pm
can anybody give me info about the best institute which provides embedded software training in mumbai (its contact details, if possible)?
New Replies:
By Madhumeeta Tare on 30 October, 2007 - 12:32 am -
Prolific provides corporate training. Yes, we can conduct training on ARM as per your requirement....
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!