Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
"I belong to no organized party. I am a Democrat."
-- Will Rogers
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Friday, November 9, 2007
from the Automation List department...
Magelis XBT N401 to 170 CCC 980 30
Topic: Communications systems and equipment.
Originally posted by mustafa on 9 November, 2007 - 1:35 am
Magelis Error Message
#203 Dialogue Table Reading Impossible.
Is this a communication error?
This is my first Magelis XBT N401 project.
New Replies:
By Skinner on 9 November, 2007 - 11:02 pm -
I solved the problem by creating a cable of my own, for the Magelis can also communicate in RS485....
By EricR_ICPDAS on 9 November, 2007 - 10:56 pm -
An RS-485 to RS-232 adapter is available at http://www.icpdas-usa.com/products.php?PID=126 . It...
from the Automation List department...
Low cost motor braking for conveyor
Topic: Motion control, servos, steppers, etc.
Originally posted by Art Terpstra on 9 November, 2007 - 1:11 am
Pallets moving on a conveyor take too long to coast to a stop without any braking system. A very low cost braking method is needed.
New Replies:
By val_99 on 9 November, 2007 - 10:57 pm -
Sounds like real dilemma. VFDs would do the job, but price is an issue. If you may, try to...
from the Challenge department...
SLC 5/05 "Faulted" program can't be cleared
Topic: PLCs and related questions.
Originally posted by Peter Procenko on 9 November, 2007 - 1:39 am
PLC program is faulted and I cannot find the error.
New Replies:
By anon on 9 November, 2007 - 10:56 pm -
It might be an ACN instruction. You should check the S:20 and S:21 registers to find the offending...
By Mike Lamond on 9 November, 2007 - 10:36 pm -
Doesn't the Status data file, Errors tab show the fault rung & file (S:20 & S:21)? I think...
from the SCADA department...
Modbus reply message
Topic: Communications systems and equipment.
Originally posted by Jason Phillips on 7 November, 2007 - 8:06 pm
When polling sites, modbus message response is [15].
New Replies:
By Jason Phillips on 9 November, 2007 - 10:55 pm -
Sorry about that. Below is a portion of the poll and receive messages. 11/05 15:38:51 - GooseMb...
By lorne on 9 November, 2007 - 1:17 am -
More information is required. If you could post your poll and receive messages (or portions...
from the Instrumentation and Control department...
Gas Burner Sequence Controllers
Topic: Continuous process industries, DCS questions.
Posted by Eng. Yazan on 9 November, 2007 - 10:51 pm
Flame lake
from the Operations department...
Liquid fuel change over.
Topic: Continuous process industries, DCS questions.
Originally posted by a-w-p-d on 21 October, 2007 - 5:20 pm
What are the criteria for changing over fuel on line?
New Replies:
By CSA on 9 November, 2007 - 10:49 pm -
This seems like a prudent course of action. After the flush is complete, it is important to...
By a_w_p_d on 9 November, 2007 - 1:49 am -
After relaying all of the points and help that I have been give from Control.com, it has been...
from the help department...
Modicon b884
Topic: PLCs and related questions.
Posted by richief on 9 November, 2007 - 10:47 pm
I need a manual for a b884.
from the Automation List department...
Eaton ELC
Topic: Application Questions and Problems
Originally posted by William Sturm on 19 June, 2007 - 11:57 pm
Has anyone used the Eaton ELC PLC controller?
New Replies:
By ironbutt on 9 November, 2007 - 10:47 pm -
They are a private labeled control from Delta of Taiwan. Not used them, so no opinions. Delta...
from the Automation List department...
Yokogawa DCS to Modbus
Topic: Communications systems and equipment.
Originally posted by Matthew C. on 15 June, 2007 - 10:37 pm
Yokogawa communication issues
New Replies:
By Zoran Cico on 9 November, 2007 - 10:37 pm -
Dear Amin, Maybe you should give us some more details about which Modbus (RTU/ASCII/TCP) and...
from the Automation List department...
Steam power plant control
Topic: Continuous process industries, DCS questions.
Posted by Mikas on 9 November, 2007 - 10:36 pm
Different types of steam power plant control
from the Automation List department...
P125-N125
Topic: Continuous process industries, DCS questions.
Posted by Jeff on 9 November, 2007 - 10:34 pm
Can TCDA card cause a p125-n125 overvoltage alarm?
from the Automation List department...
PLC + SCADA vs. WinPLC system
Topic: PLCs and related questions.
Originally posted by Jeff on 6 November, 2007 - 8:56 pm
We are in the middle of design for one of the most complex fish hatcheries ever to be built in North America. Our engineering consultant is recommending standard PLC and SCADA alarm and control system but one of our staff is really pushing a WinPLC based system...
New Replies:
By William Sturm on 9 November, 2007 - 10:32 pm -
I think Bruce was referring to the fact that they use mHz on their spec page instead of MHz for the...
By Bruce Durdle on 9 November, 2007 - 10:16 pm -
I was referring to the specifications on http://www.hosteng.com/HW-Products/WinPLC/WinPLC.htm. ...
By Curt Wuollet on 9 November, 2007 - 1:46 am -
For the record, the tiny C precursor to the MAT/plc I wrote was successfully applied in an actual...
By Michael Griffin on 9 November, 2007 - 12:33 am -
In reply to Bruce Durdle: I believe you meant 40 to 100 millisecond scan. 40 to 100...
By Michael Griffin on 9 November, 2007 - 12:26 am -
You have by this time heard a number of opinions on the WinPLC. To answer your questions more...
from the I&C department...
SPPA-T1000
Topic: Engineering and workplace issues.
Posted by gasjobs on 9 November, 2007 - 10:31 pm
working of SPPA-T1000
from the Conversion of sofware department...
Rockwell versus ABB
Topic: Software, including programming, OS issues, etc.
Originally posted by DavidS on 9 November, 2007 - 1:33 am
Is there an easy way to convert RSLogix 500 files to ABB Freelance files
New Replies:
By Michael Batchelor on 9 November, 2007 - 10:25 pm -
Man-hours of labor is the only way to convert it. It's probably not as much "hard" as it...
from the Automation List department...
Interfacing LM35 to adc0804
Topic: Sensor technologies.
Posted by michael egwurube on 9 November, 2007 - 10:23 pm
I need 2 get a diagram of the interfacing of Lm35 to an adc0804. I also need to know if 10mv/degree is too small 2 be sensed by the adc. Can anyone help with reference material like e-books and websites to check?
from the Automation List department...
Citect and mySQL
Topic: Human-Machine Interface and SCADA.
Originally posted by Alexander van Deurzen on 13 February, 2007 - 12:48 am
Citect communicating with mySQL database
New Replies:
By Heine Broers on 9 November, 2007 - 10:19 pm -
Do not use * for a lot of fields. Citect can only return a limited quantity. MySQL can also have...
from the Automation List department...
Passing a BlockDB as a parameter two levels deep
Topic: PLCs and related questions.
Originally posted by k.zonouzi ahmad on 7 November, 2007 - 8:32 pm
Is it possible to pass a DataBlock as a parameter to a first function and then pass it from that first function to another?
New Replies:
By k.zonouzi ahmad on 9 November, 2007 - 10:16 pm -
Hi dear Chartier, Declaring Block_DB as a parameter type is only permitted in VAR_INPUT part of...
By k.zonouzi ahmad on 9 November, 2007 - 12:31 am -
Hello again, I forgot to say that it is in Siemens S7. Best regards, k.zonouzi ahmad...
By dchartier on 9 November, 2007 - 12:21 am -
Hello; If this is for Siemens S7 CPUs (you don't mention the model of PLC), I would suggest that...
from the Profibus department...
ABB to Siemens Profibus DP
Topic: Computers in manufacturing; also hardware discussion.
Originally posted by MKunold on 30 October, 2007 - 1:10 am
I am looking for a GSD file, CI541 to S7 315 F.
New Replies:
By September, Clyde on 9 November, 2007 - 10:12 pm -
Hi, Check here - ...
Topic: Engineering and workplace issues.
Originally posted by Anonymous on 29 April, 2007 - 12:51 pm
What is the effect of water injection in Gas Turbine on Efficiency
New Replies:
By CSA on 9 November, 2007 - 1:54 am -
It takes less water (mass flow-rate) than steam for the same emissions reduction. This is because...
By Alex C on 9 November, 2007 - 12:16 am -
I have another question relating to steam and water injection into the combustion chamber. I...
from the Instrumentation department...
MarkV Simplex
Topic: Continuous process industries, DCS questions.
Originally posted by vedprakash rao on 9 November, 2007 - 12:38 am
Reg TCEA of MarkV Simplex Panel
New Replies:
By CSA on 9 November, 2007 - 1:49 am -
If it's configured properly, no. The three TCEAs are independent of each other and it should take...
from the Automation List department...
Distance monitoring
Topic: Sensor technologies.
Originally posted by baby_jones on 5 November, 2007 - 4:03 pm
Monitoring distance between cars/vehicles
New Replies:
By Curt Wuollet on 9 November, 2007 - 1:38 am -
Yes, but you get much better turndown with the tape measure. Especially under 12 inches. Of...
Topic: Continuous process industries, DCS questions.
Originally posted by Ravi on 4 November, 2007 - 1:14 pm
Conductor NT Ver 4.0 loading on the Windows 2000 Operating System Base Conductor Installation failed message
New Replies:
By Chris Jennings on 9 November, 2007 - 1:35 am -
Conductor NT 4.0 can't be loaded on a Windows 2000 computer. You will need to upgrade to Conductor...
from the Automation List department...
Wet leg in differential pressure measurement
Topic: Sensor technologies.
Originally posted by Chronis Theodos on 7 November, 2007 - 8:25 pm
Diff. Pressure Transmitter high pressure connection in the wet leg
New Replies:
By Bryce Gillan on 9 November, 2007 - 1:33 am -
The DP cell is connected to the process with the (+) and (-) connected as they would on a system...
By Juan Pinzon on 9 November, 2007 - 12:39 am -
Chronis, Wet leg is used normally in level measure, because if the gas or steam (water, HC)...
from the Automation List department...
ABB Bailey Conductor NT 5.0 Graphics
Topic: Human-Machine Interface and SCADA.
Originally posted by lawebster on 3 October, 2007 - 12:02 am
Trying to develop graphics, and the embedded editor, Grafx, is not very helpful. Has anyone done any graphics work using this editor? Is there another way?
New Replies:
By Chris Jennings on 9 November, 2007 - 1:31 am -
As far as I know the graphics language used is actually SL-GMS (http://www.sl.com/) by Sherrill...
from the netiquette department...
Synchronizing 2 asynchron motor
Topic: Motion control, servos, steppers, etc.
Originally posted by Darius on 2 November, 2007 - 8:36 pm
Synchronizing products coming out from the molding machine on to the conveyer.
New Replies:
By Gilles Allard on 9 November, 2007 - 1:24 am -
That function is available from many VFD suppliers. Yaskawa and Siemens come to my mind. The...
By Michael Griffin on 9 November, 2007 - 12:19 am -
A vector drive with electronic gearing might be able to do this. I don't want to recommend a...
from the Automation List department...
Motorola ACE 3640
Topic: Application Questions and Problems
Posted by Peter on 9 November, 2007 - 1:23 am
Motorola's New ACE 3640 H/W, STS S/W & MCP-T:
from the Automation List department...
Foxboro DCS
Topic: Application Questions and Problems
Originally posted by Anonymous on 8 July, 2006 - 9:56 pm
how reliable is Foxboro DCS
New Replies:
By Walt Boyes on 9 November, 2007 - 1:20 am -
At the risk of seeming obvious, have you tried http://www.foxboro.com? Foxboro also has just oodles...
from the Automation List department...
Regenerative VFD motor setup
Topic: Motion control, servos, steppers, etc.
Originally posted by scan_plc on 7 November, 2007 - 8:02 pm
Regenerative Drive Test Bench Setup
New Replies:
By B on 9 November, 2007 - 1:20 am -
Depending on the size of motors in the application you should use the Unidrive SP from...
By Brian Beal on 9 November, 2007 - 1:05 am -
I think that you really want to control torque using the ABB drive instead of speed. That is the...
from the Automation List department...
S7 to Quantum - Modbus communications
Topic: Communications systems and equipment.
Originally posted by A Dobson-Holt on 6 October, 2007 - 12:03 am
I am trying to set up a Read/Write communications from S7 PLC to a Quantum using the S7 Modbus TCP Driver from Siemens. I am having difficulty getting any communication between the two...
New Replies:
By Aikona on 9 November, 2007 - 1:15 am -
It took us 4 hours to setup comms between a S7 and a Premium PLC using the software from Siemens. ...
from the Automation List department...
S7/MPI communication to Modbus TCP/IP
Topic: Communications systems and equipment.
Originally posted by Lewis on 31 May, 2007 - 11:56 pm
Has anyone had any experience with Gateways that Allow connectivity of S7/MPI Siemens PLCs and Modbus TCP/IP protocol?
New Replies:
By Anonymous on 9 November, 2007 - 1:14 am -
We just complete a project reading from a Modbus to a S7 300 PLC via TCP/IP. On the PLC we...
from the Automation List department...
Making a PC emulate a printer
Topic: Communications systems and equipment.
Originally posted by ekeil on 25 May, 2004 - 9:52 am
I have a device with a standard LPT port (designed to be cabled directly to a printer to print status messages) and I want to connect it to a PC to capture the status messages for display.
New Replies:
By Tester on 9 November, 2007 - 1:09 am -
You can download a Windows version for capturing from LPTCAP from...
from the Automation List department...
Concept: Virtual indication to InTouch HMI
Topic: Human-Machine Interface and SCADA.
Originally posted by Muhammad Pervaiz on 2 November, 2007 - 12:21 am
How can I move valve info to HMI without using the feedback valve position signal/contacts?
New Replies:
By Hildemaro Carrasquel on 9 November, 2007 - 1:08 am -
Hello, Use Modsim, do you know it?...
from the Programming languages department...
How To Excute the DOS Commands in Visual Basic
Topic: Programming languages.
Originally posted by Anonymous on 25 August, 2005 - 2:40 pm
i can't run the DOS commands in VB programs. Please help me.
New Replies:
By Vitor on 9 November, 2007 - 1:06 am -

I was looking for a snippet code that could help me type DOS commands into VB, I wrote a...

from the Proposals department...
RSView SE licenses
Topic: Human-Machine Interface and SCADA.
Posted by Adeel Hassan on 9 November, 2007 - 12:32 am
RSView SE, number of client licenses
from the Please Help----URGENT!!! department...
Java j2ee training in Bangalore and Kolkata
Topic: Information resources, documentation.
Originally posted by Anonymous on 3 June, 2006 - 1:16 am
Java J2ee training in Kolkata and Bangalore with Live Project and Placement Opportunities...
New Replies:
By halumbo on 9 November, 2007 - 12:29 am -
Guys this domain is hosted in US, there are many forums in India also, try there....
from the C&I department...
Gas Turbine Exhaust Temperature Control
Topic: Application Questions and Problems
Originally posted by Grishma on 9 February, 2007 - 6:47 pm
Should two turbines with same CPD generate equal power output?
New Replies:
By Roman Cruz on 9 November, 2007 - 12:28 am -
We have 3 Frame 6 GE Gas Turbines. I had the same problem in the Unit 1. TXset depends of PCD...
from the Automation List department...
MV cable size calculation
Topic: Engineering and workplace issues.
Originally posted by FN on 3 November, 2007 - 10:47 am
how to calculate the size of the medium voltage cable
New Replies:
By FN on 9 November, 2007 - 12:26 am -
Dear Phil, thankx for your reply. Actually I want to know what values we should consider for...
from the Automation List department...
Modbus RTU - RJ45 and daisy chaining
Topic: Communications systems and equipment.
Originally posted by tailgunner on 28 August, 2007 - 1:19 am
Can RJ45 be daisy chained in any way?
New Replies:
By Dean Norton on 9 November, 2007 - 12:12 am -
WAGO also has an extensive line of RJ-45 to terminal block interface modules. See the following...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!