Member Login
Search
Past & Future Posts
Sponsored Communities
Cool stuff
Neat Stuff

Visit our shop for nerds in control lifestyle products.
Thermal Overload
The threads that wouldn't die...
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
Fortune
The qotc (quote of the con) was Liz's:
"My brain is paged out to my liver"
"My brain is paged out to my liver"
RSS Feed
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Posts from...
Sunday, November 11, 2007Pallets moving on a conveyor take too long to coast to a stop without any braking system. A very low cost braking method is needed.
New Replies:
By Mark Davis on 11 November, 2007 - 6:04 pm -
By Mark Davis on 11 November, 2007 - 6:04 pm -
Hello,
Simple, move the current stopping apperatus, further back down the line away from the...
Citect communicating with mySQL database
New Replies:
By Nathan Boeger on 11 November, 2007 - 6:03 pm -
By Nathan Boeger on 11 November, 2007 - 6:03 pm -
That is correct. Relational databases typically make more sense taller rather than wide. ...
Trying to find an elegent solution to use RSView State display
New Replies:
By Trevor Ousey \(list\) on 11 November, 2007 - 6:00 pm -
By Trevor Ousey \(list\) on 11 November, 2007 - 6:00 pm -
Maybe I am missing something, but just create the tag as a DINT (or INT) instead of a REAL, and...
I'm having some diffculties in getting the signals of the PLC back to the DCS
New Replies:
By Tom Tran on 11 November, 2007 - 5:59 pm -
By Tom Tran on 11 November, 2007 - 5:59 pm -
1. How about telling us which Honeywell system do you have? TDC2000? TDC3000 with HPM controllers...
Very Low Flow Measurement
New Replies:
By Rohit Chandak on 11 November, 2007 - 5:58 pm -
By Rohit Chandak on 11 November, 2007 - 5:58 pm -
I would recommend Capillary Based Thermal Mass Flow Meter which are inexpensive to offer +/-1% of...
jagXtreme and Delphi
New Replies:
By Roy on 11 November, 2007 - 5:57 pm -
By Roy on 11 November, 2007 - 5:57 pm -
Hi Annon,
I have used this product twice with AB SLC and Opto22, send me an e-mail and I will send...
Is Iconics better than Wonderware, Citect, Intellution?
New Replies:
By SM on 11 November, 2007 - 5:56 pm -
By SM on 11 November, 2007 - 5:56 pm -
Nathan
Maybe I didn't provide enough info. We didn't lose the key. The hard drive failed so we...
We are in the middle of design for one of the most complex fish hatcheries ever to be built in North America. Our engineering consultant is recommending standard PLC and SCADA alarm and control system but one of our staff is really pushing a WinPLC based system...
New Replies:
By Curt Wuollet on 11 November, 2007 - 5:55 pm -
By Curt Wuollet on 11 November, 2007 - 5:55 pm -
I don't think there's anything wrong with the basic idea or PC control in general, but you would...
By Curt Wuollet on 11 November, 2007 - 5:50 pm - Hi Michael I seriously considered porting a Linux PLC to the WinPLC. Seem quite doable since there...
By Michael Griffin on 11 November, 2007 - 5:46 pm - In reply to Curt Wuollet: I have experience with a couple of PC based systems in a different...
whenever we synchronise the machine...
New Replies:
By CSA on 11 November, 2007 - 5:44 pm -
By CSA on 11 November, 2007 - 5:44 pm -
You should most likely consult with the company who performed the excitation revamp to discuss what...
how to calculate the size of the medium voltage cable
New Replies:
By Phil Corso, PE on 11 November, 2007 - 5:42 pm -
By Phil Corso, PE on 11 November, 2007 - 5:42 pm -
Responding to FN's 09-Nov (00:26) reply... the derating factor 0.5 is far too severe for the design...
Need help printing a Modicon Concept software
New Replies:
By ST - WP on 11 November, 2007 - 5:41 pm -
By ST - WP on 11 November, 2007 - 5:41 pm -
Hi,
I think that You may to print a program if You have a source version...
If a program receive...
Need to load Step 5 v6.65 on Windows 2000
New Replies:
By ST - WP on 11 November, 2007 - 5:40 pm -
By ST - WP on 11 November, 2007 - 5:40 pm -
Hi,
I am not sure but propable STEP5 ver 6.65
not services NTFS system files... a format FAT...
I need any information abou Composer for Bailey INFI90
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.
Our Advertisers
Help keep our servers running...
Patronize our advertisers!
Patronize our advertisers!










