Saturday, November 17, 2007
from the Automation department...
Polling time
Topic: PLCs and related questions.
Originally posted by adello on 11 October, 2007 - 12:53 am
Polling with large SCADA with 33 PLCs/DCSs
New Replies:
By adel on 17 November, 2007 - 10:18 pm -
sorry our WAN is bases on E1 channels that are in multiples of 64K . more than on channel can be...
from the Automation List department...
Level switch selection for sludge and slurry
Topic: Continuous process industries, DCS questions.
Originally posted by Hamid on 14 November, 2007 - 11:26 pm
The question is the right choice for level switch proper for sludge and slurry.
New Replies:
By Roy on 17 November, 2007 - 10:18 pm -
Hamid, I worked in mining for many years. Ultrasonic meters work well on agitated tanks provided...
from the Automation List department...
Siemens PCS7 as a DCS
Topic: Application Questions and Problems
Originally posted by Anil on 1 September, 2006 - 9:55 pm
Siemens PCS7: Does it have the features to be called as a true DCS or is it a good PLC???
New Replies:
By Tom Tran on 17 November, 2007 - 10:17 pm -
So far I have seen several excellent criteria for a good DCS system. But we should consider: ...
By Mikho S on 17 November, 2007 - 12:52 am -
Hi, Any good DCS allows new control, I/O configuration and HMI to be developed, tested and...
from the power department...
Intervalve pressure fluctuations in Mark V
Topic: Application Questions and Problems
Originally posted by gt___maint on 21 September, 2007 - 11:33 pm
Variations in P2 intervalve pressure
New Replies:
By gt__maint on 17 November, 2007 - 10:15 pm -
when we opened the front plate below the srv & gcv compartments in the running turbine, we saw...
from the Automation List department...
Allen Bradley + MODBUS/RTU
Topic: Communications systems and equipment.
Originally posted by Alejandro on 17 November, 2007 - 1:09 am
Does anyone know if there is any device or product to interface SLC 500 5/03 to a MODBUS/RTU network of other brands and devices?
New Replies:
By Eddie Willers on 17 November, 2007 - 10:13 pm -
The most common and straightforward way to interface A-B controllers and Modbus network devices is...
By David on 17 November, 2007 - 10:13 pm -
Prosoft is an Allen Bradley 'partner', specializing in communications modules. ...
By Roy on 17 November, 2007 - 10:12 pm -
Alejandro, Check out the "Prosoft" module, these slot into AB racks and have AB...
By Tom Tran on 17 November, 2007 - 10:12 pm -
Alejandro, You can have a Prosoft 3150 MCM module installed in the SLC rack. It is a...
By Pablo H. Halperin on 17 November, 2007 - 10:11 pm -
Alejandro: Try Prosoft. You can find what you need at ...
from the Automation department...
Legacy Protocol
Topic: PLCs and related questions.
Posted by Adelabaza on 17 November, 2007 - 10:13 pm
communicate with older RTU's
from the Automation List department...
Jbus to Fieldserver communication
Topic: Communications systems and equipment.
Originally posted by Shyam on 13 November, 2007 - 11:46 pm
How to communicate UPS with PC through Fieldserver
New Replies:
By dchartier on 17 November, 2007 - 10:09 pm -
Hello shyam; So basically you have a Modbus RS-485 network established, but you recieve no valid...
By Shyam on 17 November, 2007 - 1:04 am -
Dear Sir, Thanks for your reply. We are using Fieldserver FS-X40. We have installed 90-net...
from the Motor Braking department...
Motor Braking by Shorting Armature Windings
Topic: Motion control, servos, steppers, etc.
Originally posted by cyam on 17 November, 2007 - 1:25 am
How to slow down a motor quicker by wiring resistors across armature windings?
New Replies:
By Phil Corso, PE on 17 November, 2007 - 10:08 pm -
Responding to Cyam's 17-Nov (01:45)... I suggest the following procedure, but only if the...
By Roy on 17 November, 2007 - 10:07 pm -
Cyam, Shorting the windings with resistors should work well as your motor will try to act as an...
from the Instrument department...
PLC Scan Time
Topic: PLCs and related questions.
Originally posted by Vasudev on 2 October, 2007 - 1:51 am
PLC scan time and TUV certification
New Replies:
By aliaswn on 17 November, 2007 - 10:07 pm -
Yes TUV requirement is 300ms for process and 500ms for fire and gas. I dont think you will need...
from the Automation List department...
Hydraulic valves
Topic: Engineering and workplace issues.
Originally posted by instruguy on 17 November, 2007 - 1:51 am
Hydraulic Vs. Pneumatic valves
New Replies:
By Roy on 17 November, 2007 - 10:06 pm -
Hi instruguy, In 40 years I have rarely seen hydraulic actuators used unless it's a water control...
Topic: Application Questions and Problems
Originally posted by Mike Perreca on 2 November, 2007 - 12:48 am
Need help searching for control system for Sr Design Project
New Replies:
By Roy on 17 November, 2007 - 10:05 pm -
Mike, You might also check out Opto22.com They have a modular PLC system that uses ethernet. The...
By LeGa on 17 November, 2007 - 1:52 am -
Look at new digital Elmo servo amp (http://www.elmomc.com) - I hope you'll find what you need....
from the Automation List department...
TXP sytem
Topic: Application Questions and Problems
Posted by fahad on 17 November, 2007 - 10:04 pm
using SQL in TXP ES680
from the Automation List department...
Calculation of cable size
Topic: Engineering and workplace issues.
Originally posted by Anonymous on 3 July, 2007 - 12:41 am
How to calculate cable size, switchgears and fuses for feeders and equipment?
New Replies:
By Abhishek on 17 November, 2007 - 10:04 pm -
the calculation explained above is right basically but actually transformer sizing also depends...
from the Automation List department...
mitsubishi plc tutorial
Topic: PLCs and related questions.
Posted by rasta_martha on 17 November, 2007 - 10:02 pm
I need a mitsubishi plc tutorial to convert my project from omron plc program to mitsubiahi plc program
from the Automation List department...
s7 300 cpu change
Topic: PLCs and related questions.
Posted by jay on 17 November, 2007 - 10:01 pm
convert the cpu of s7 300 plc with s7 400?
from the Automation List department...
Thermal Relief Valves
Topic: Application Questions and Problems
Originally posted by Anonymous on 5 October, 2007 - 10:54 pm
Selection of thermal relief valves
New Replies:
By Roy on 17 November, 2007 - 9:45 pm -
Hi, We use thermal relief valves on heat exchangers in case they are blocked in and the...
By S. Curyk P.E. on 17 November, 2007 - 1:23 am -
A thermal relief valve is used when a liquid is blocked (i.e. a line or pipe between two block...
from the Engg department...
Modbus and MultiDropping
Topic: PLCs and related questions.
Posted by Yousaf on 17 November, 2007 - 9:44 pm
Is multi dropping possible on modbus? if yes how?
from the Automation List department...
need a tutorial of Bailey INFI-90 DCS
Topic: Application Questions and Problems
Originally posted by Anonymous on 12 October, 2006 - 11:55 pm
need a tutorial for Bailey infi-90 dcs...
New Replies:
By Bob on 17 November, 2007 - 1:56 am -
I have the solution for you. A company has redesigned the faceplate. Write me at...
Topic: Motion control, servos, steppers, etc.
Originally posted by sarabjot singh manku on 25 October, 2007 - 10:40 pm
We are going to control the position and speed of a stepper motor using em 253 positioning module with Siemens S7 200 PLC (CPU 222, version - 02.01).
New Replies:
By LeGa on 17 November, 2007 - 1:50 am -
Because stepper is open loop position control? That you have cheaper solution with HSOutputs for...
from the Automation List department...
Multiply analog values - budget method required
Topic: Human-Machine Interface and SCADA.
Originally posted by Stephen on 15 November, 2007 - 2:18 pm
I need to multiply an analogue value, from a sensor, by another value. The result will drive a digital display. I am looking for a standard product, not a PLC.
New Replies:
By Carl Burgess on 17 November, 2007 - 1:39 am -
Check out the Medacs stuff from Status Instruments http://www.status.co.uk Regards, Carl ...
from the Installation department...
Thermal Mass Flow Meters
Topic: Engineering and workplace issues.
Originally posted by Saqib Ali Rana on 20 August, 2007 - 11:15 pm
I want to know the general procedure for Thermal Mass Flow Meters Installation.
New Replies:
By ELLI HUTCHINSON on 17 November, 2007 - 1:39 am -
You may go to our website: http://www.thermalinstrument.com...
from the Instrumentation and control department...
Preventive maintenance
Topic: Engineering and workplace issues.
Posted by yazan a on 17 November, 2007 - 1:35 am
Preventive maintenance schedule for I&C
from the Control department...
SFC system
Topic: Engineering and workplace issues.
Posted by walterik on 17 November, 2007 - 1:33 am
Description of the static frequency converter in gas turbines
from the maintenance department...
Digital input
Topic: Sensor technologies.
Posted by br on 17 November, 2007 - 1:24 am
How to connect normally close and normally open contacts as two different digital inputs?
from the GE Mark V department...
Start up trouble
Topic: Software, including programming, OS issues, etc.
Originally posted by Keith on 29 September, 2007 - 10:31 am
Mark V start up gets to 95% speed and stays there!
New Replies:
By RTK on 17 November, 2007 - 1:10 am -
Hello, Is the aux lube oil pump and/or the aux hydraulic pump still running? On occassion we...
from the Gas Turbine Control Engineering department...
Gas Turbine Control
Topic: Continuous process industries, DCS questions.
Posted by Dik van der Linden on 17 November, 2007 - 1:10 am
What does CPD/FSR refdif mean?
from the Automation List department...
Firewall On Top of OPC
Topic: Local and wide area networking in factory automation.
Originally posted by Salem on 22 May, 2005 - 1:59 pm
planning to install a firewall between the PI and OPC server to protect the control network. How does that affect the data flow between the PI and OPC server?
New Replies:
By Saber on 17 November, 2007 - 1:06 am -
Hello Salem, Do you still need help on this subject? If yes drop me an email. For your...
from the gt department...
Mark V signal names
Topic: Application Questions and Problems
Posted by gt__maint on 17 November, 2007 - 1:05 am
Signal names and their significance
from the Software in automation department...
PLC S7-200 software
Topic: Software, including programming, OS issues, etc.
Originally posted by Zafar on 9 November, 2006 - 12:12 am
Which software I can use to program the S7-200 PLC?
New Replies:
By bestyang on 17 November, 2007 - 1:02 am -
Only $100 for 1pic...
Topic: Sensor technologies.
Posted by xtranox on 17 November, 2007 - 1:01 am
The best method to calculate overall accuracy for natural gas metering system
from the Automation List department...
Can Siemens PCS7 be considered as a True DCS?
Topic: Application Questions and Problems
Originally posted by Dr. R. Murugesan on 24 March, 2007 - 10:17 am
All the Vendors claim their offering is a true DCS and 'can perform the assigned role'...
New Replies:
By Mikho on 17 November, 2007 - 12:56 am -
My industry colleagues tell me that some controllers cannot be updated with fresh (i.e. additional)...
from the Maintenance department...
Trouble shooting of Elektronikon panel
Topic: Engineering and workplace issues.
Originally posted by Suleman on 20 May, 2007 - 2:24 pm
when we start the compressor, message is "Wrong Phase Seq"...
New Replies:
By anoonmous on 17 November, 2007 - 12:56 am -
The problem in your compressor is of the main 3 phase supply. You have to make a few attempts by...
from the Automation List department...
Twido Canopen eds import
Topic: Communications systems and equipment.
Posted by ak0s on 17 November, 2007 - 12:54 am
Cannot use an eds file, data object missing error
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.