Member Login
Search
Jump to a Date
Sponsored Communities
Cool stuff
Neat Stuff

Visit our shop for nerds in control lifestyle products.
Thermal Overload
The threads that wouldn't die...
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
Fortune
"When are you BUTTHEADS gonna learn that you can't oppose Gestapo
tactics *with* Gestapo tactics?"
-- Reuben Flagg
tactics *with* Gestapo tactics?"
-- Reuben Flagg
RSS Feed
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Posts from...
Sunday, November 18, 2007we want tutsano dispensing units to computer with RS-485
How to slow down a motor quicker by wiring resistors across armature windings?
New Replies:
By Michael Griffin on 18 November, 2007 - 5:30 pm -
By Michael Griffin on 18 November, 2007 - 5:30 pm -
You will probably wish to keep the peak braking current within the normal motor operating...
Why 4-20 ma is used in Analog Signals?
New Replies:
By sudhakar on 18 November, 2007 - 5:29 pm -
By sudhakar on 18 November, 2007 - 5:29 pm -
as for as my knowledge, standard a to d converter of value 0 to 5 v requires 250 ohms for the...
Cannot use an eds file, data object missing error
New Replies:
By Dweebyone on 18 November, 2007 - 5:29 pm -
By Dweebyone on 18 November, 2007 - 5:29 pm -
What version of Twidosuite are you using?
Can you Email me the EDS file, I can take a look.
...
The best method to calculate overall accuracy for natural gas metering system
New Replies:
By syurish on 18 November, 2007 - 5:25 pm -
By syurish on 18 November, 2007 - 5:25 pm -
>a = sqrt (err1^2+err2^2+err3^2+...)
>where a is the overall accuracy.
>
>I believe...
xbt-n401 to twido cable (xbt-z968)
convert the cpu of s7 300 plc with s7 400?
New Replies:
By dchartier on 18 November, 2007 - 5:23 pm -
By dchartier on 18 November, 2007 - 5:23 pm -
Hello;
S7-300 and S7-400 PLCs are very different beasts, in terms of power and physical setup. The...
Calculation of Repeatability
New Replies:
By douthomas on 18 November, 2007 - 5:15 pm -
By douthomas on 18 November, 2007 - 5:15 pm -
My reply was based on NIST. I have no access to the ISA standard. As the measurements will normally...
so I can make some modification on it and re-download again to Allen-Bradley PanelView Plus,,,
Is multi dropping possible on modbus? if yes how?
New Replies:
By aan - on 18 November, 2007 - 5:10 pm -
By aan - on 18 November, 2007 - 5:10 pm -
From my experience, no special configuration needed to connect wonderware to Modicon Quantum 434...
planning to install a firewall between the PI and OPC server to protect the control network. How does that affect the data flow between the PI and OPC server?
New Replies:
By Nathan Boeger on 18 November, 2007 - 5:08 pm -
By Nathan Boeger on 18 November, 2007 - 5:08 pm -
As long as someone's reviving this thread I'll throw in my $.02.
The more important firewall is...
I need to make a "visual interface" to a machine that is using a zelio logic.
New Replies:
By anonymous on 18 November, 2007 - 5:07 pm -
By anonymous on 18 November, 2007 - 5:07 pm -
it's very useful - and i want to know how to comm with communication interface. cables and...
What type of cable can be used for Gas Detectors in Zone 0.
New Replies:
By sudha on 18 November, 2007 - 5:03 pm -
By sudha on 18 November, 2007 - 5:03 pm -
what is the main difference between fire resistant and flame retardant cables ?
can any one...
Signal names and their significance
New Replies:
By CSA on 18 November, 2007 - 5:01 pm -
By CSA on 18 November, 2007 - 5:01 pm -
The answer to your first question is in the CSP. Typically FSR becomes FSROUT when it's applied to...
What does CPD/FSR refdif mean?
New Replies:
By CSA on 18 November, 2007 - 5:00 pm -
By CSA on 18 November, 2007 - 5:00 pm -
Someone might have programmed the control system to calculate the difference between the CPD-biased...
Description of the static frequency converter in gas turbines
New Replies:
By ravi kisore.p on 18 November, 2007 - 4:58 pm -
By ravi kisore.p on 18 November, 2007 - 4:58 pm -
Hai. we have load commutated inverter called LCI.In this the synchronous generator works as the...
By CSA on 18 November, 2007 - 4:56 pm - Also referred to as a "static starter" or and LCI (Load Commutated Inverter), this type...
I have a Panelview600 RS232(DH485). How to interface with 1761-NET-AIC .
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.
Our Advertisers
Help keep our servers running...
Patronize our advertisers!
Patronize our advertisers!











