Wednesday, November 21, 2007
from the Automation List department...
Govenor controller of Turbine-Generator
Topic: PLCs and related questions.
Originally posted by Mohammad samie on 21 November, 2007 - 12:27 pm
How to adjust parameters of a govenor speed controller for parallel turbin-generators,
New Replies:
By CSA on 21 November, 2007 - 3:53 pm -
Can you please explain us how you operate the turbinE-generators? If they are operated to supply an...
from the Automation List department...
OPC server for Yokagawa WT1600
Topic: Software, including programming, OS issues, etc.
Originally posted by Bob Peterson on 3 August, 2007 - 12:50 pm
Anyone aware of an OPC server for this product?
New Replies:
By Fred Loveless on 21 November, 2007 - 3:51 pm -
Yokogawa has developed several Profiles for Kepware's UCON(User Configurable Driver) that the...
By Bob Peterson on 21 November, 2007 - 12:32 pm -
they have one but it prevents you fom using wtviewer and only updates once a second....
By Dave MH on 21 November, 2007 - 12:30 pm -
There are products available that allow you to develop your own OPC server that don't require a lot...
from the Automation List department...
Hydraulic valves
Topic: Engineering and workplace issues.
Originally posted by instruguy on 17 November, 2007 - 1:51 am
Hydraulic Vs. Pneumatic valves
New Replies:
By instruguy on 21 November, 2007 - 3:51 pm -
Hi Roy Thanks a lot....
from the Automation List department...
MKV issues after power up
Topic: Human-Machine Interface and SCADA.
Originally posted by Danno on 6 November, 2007 - 8:56 pm
MKV Cores Not at A7 status
New Replies:
By CSA on 21 November, 2007 - 3:50 pm -
I think now you have a cable problem and/or a hardware jumpe. You may be a victim of the lack of...
By Danno on 21 November, 2007 - 1:44 am -
Thanks for your reply. I did check the DCC/LCC keypad and found that the TCEA cards in the...
from the Automation List department...
Bubbler method to measure solution height in tanks
Topic: Continuous process industries, DCS questions.
Originally posted by Manmeet on 21 November, 2007 - 12:38 pm
Measuring the height of the solutions in tanks through diffrential pressure (DP) Transmitter using bubbler method.
New Replies:
By Bill Hendrick on 21 November, 2007 - 3:48 pm -
Manmeet, The theory and limitations of measuring level using dP and bubblers is the same. You...
By itech on 21 November, 2007 - 3:47 pm -
I think you are out of luck, the interference of two different liquids is not possible with a...
from the Automation List department...
ControlNet Network Scheduling
Topic: PLCs and related questions.
Posted by BIlly on 21 November, 2007 - 3:47 pm
ControlNet Scheduling via RSnetWorx
from the Automation List department...
Current of Three Phase Convertor
Topic: Application Questions and Problems
Originally posted by James Isaac on 20 November, 2007 - 7:54 pm
Relation of DC and AC current in a three thyristor speed controller of DC motor
New Replies:
By Phil Corso, PE on 21 November, 2007 - 12:46 pm -
Responding to James Isaac's 20-Nov-07 (19:54) question... there are number of relationships...
from the power department...
Intervalve pressure fluctuations in Mark V
Topic: Application Questions and Problems
Originally posted by gt___maint on 21 September, 2007 - 11:33 pm
Variations in P2 intervalve pressure
New Replies:
By Greg Ponto on 21 November, 2007 - 12:45 pm -
We have also had interstage fuel pressure cycling, from day one, on all 9 MKV controlled 7FA...
from the Automation List department...
Motor Starter
Topic: Motion control, servos, steppers, etc.
Originally posted by Prakash on 18 November, 2007 - 5:12 pm
Solid state motor starter
New Replies:
By Phil Corso, PE on 21 November, 2007 - 12:41 pm -
Responding to forstand's 20-Nov (19:42) comments: 1) Loss-of-phase would prevent the mmotor from...
from the Automation List department...
Analog to PWM conversion
Topic: PLCs and related questions.
Originally posted by nathna on 20 November, 2007 - 12:35 pm
Analog to PWM digital ouput conversion
New Replies:
By aan - on 21 November, 2007 - 12:40 pm -
To convert analog signal to PWM, you can use timer. First, convert or scale analog input value...
from the Automation List department...
SMS to DNP3/Modbus/OPC Data Converter
Topic: Communications systems and equipment.
Originally posted by Glen Downie on 21 November, 2007 - 1:42 am
Converting data contained in SMS text messages to DNP3/Modbus or OPC Data types/protocols.
New Replies:
By David on 21 November, 2007 - 12:37 pm -
Look at the similar situation covered as 'string variables in Modbus' in this thread: ...
from the Maintenance department...
APACS + QUADLOC
Topic: Communications systems and equipment.
Originally posted by DAMENE Amar on 13 November, 2007 - 12:08 am
Loss of communication over DCS APACS + QUADLOC on compression gas
New Replies:
By Pascal Poirier on 21 November, 2007 - 12:36 pm -
The MNET communication (and MBX communication modules) is now obsolete. You can now use IEM modules...
from the Automation List department...
Using a UV lamp
Topic: Engineering and workplace issues.
Originally posted by none on 20 November, 2007 - 7:13 pm
Using a lamp that emits UV to test a UV flame detector
New Replies:
By Dave MH on 21 November, 2007 - 12:34 pm -
If you are testing a fire detection device then you have to use a UV test lamp supplied or...
from the AC Motor Speed Control department...
Prostar Inverter F1500-G Series
Topic: Motion control, servos, steppers, etc.
Posted by Mohammad Hamdan on 21 November, 2007 - 12:32 pm
What electronic parts (MCB, Contactor...) do i need when i am connecting Inverter of Prostar Inverter F1500-G0185T3C to a 3ph AC motor!
from the ENG department...
wincc to procidia
Topic: Programming languages.
Posted by MEHDIE on 21 November, 2007 - 12:26 pm
how can I connect procidia or 353 controller moore to wincc procidia
from the Electrical engg department...
Generator Field
Topic: Engineering and workplace issues.
Originally posted by achumman on 20 November, 2007 - 12:33 pm
Reason for using DC power for alternator field winding.
New Replies:
By naresh on 21 November, 2007 - 1:58 am -
If you want steady magnetic field you are using DC. But in case of AC the field strength will...
By Curt Wuollet on 21 November, 2007 - 1:14 am -
You would get some really interesting waveforms. Intuitively, your output waveforms would be ...
By Phil Corso, PE on 21 November, 2007 - 12:52 am -
Responding to Achumman's 20-Nov (12:33) question... This subject was covered in Thread # 1026226790...
from the Manufacturing Engineering department...
Deka Drill Press
Topic: Motion control, servos, steppers, etc.
Originally posted by Michael Ha on 20 November, 2007 - 8:02 pm
Readout for feed valve
New Replies:
By Curt Wuollet on 21 November, 2007 - 1:50 am -
You could install the scales used on mills for DRO and sample for rate. Or you could use a LVDT. ...
from the Automation List department...
Yokogawa DCS to Modbus
Topic: Communications systems and equipment.
Originally posted by Matthew C. on 15 June, 2007 - 10:37 pm
Yokogawa communication issues
New Replies:
By Junaid on 21 November, 2007 - 1:48 am -
Is there any one who can help me to solve a similar problem? I want to implement Modbus in Yokogawa...
from the Automation List department...
Calculation of cable size
Topic: Engineering and workplace issues.
Originally posted by Anonymous on 3 July, 2007 - 12:41 am
How to calculate cable size, switchgears and fuses for feeders and equipment?
New Replies:
By Steven on 21 November, 2007 - 1:45 am -
If you want to work to IEC standards you can use the following free cable sizing tool: ...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.