Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
"It's men like him that give the Y chromosome a bad name."
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Sunday, December 2, 2007
from the Programming Software department...
Fpsoft ver. 1.1 for the NAIS FPO
Topic: PLCs and related questions.
Posted by 10 years of note gone in 60sec on 2 December, 2007 - 9:12 pm
Does anyone have Fpsoft ver. 1.1 for the NAIS FPO
PLC. My Laptop was stolen. I have, but do not like the new ver Fpwin Pro...
from the DH+ department...
DHRIO and 1770KF2
Topic: PLCs and related questions.
Originally posted by billy on 29 November, 2007 - 1:36 am
Communication between a ControlLogix and a computer
New Replies:
By Trevor Ousey on 2 December, 2007 - 9:04 pm -
G'day Billy, I only DHRIO modules into the project if we have Remote IO (RIO) otherwise the IO...
from the Automation List department...
Problems about AB1756-PLC
Topic: PLCs and related questions.
Originally posted by zhangjc on 2 December, 2007 - 6:44 pm
Need for your help
New Replies:
By Trevor Ousey on 2 December, 2007 - 9:02 pm -
First thing, have you got the right firmware in the modules, it seems you have mentioned the...
By Bob Peterson on 2 December, 2007 - 9:01 pm -
I would bet that the AB manuals for these devices will give you a good idea of what is going on....
from the PLC Personel department...
Wierd CPU Problem
Topic: PLCs and related questions.
Originally posted by Clayton Robbins on 1 December, 2007 - 1:09 am
Every time I plug in my Cat5 cable to the CPU the entire PLC shuts off.
New Replies:
By Curt Wuollet on 2 December, 2007 - 8:59 pm -
That would explain it. There's power on the port Regards cww...
By Bob Peterson on 2 December, 2007 - 8:57 pm -
The 5/04 does not have an RJ45 port. The DH+ port is either a small circular connector or a phoenix...
By Mickey on 2 December, 2007 - 6:15 pm -
The SLC5/04 does not have a ethernet port. DH+ and serial only....
By Tom Tran on 2 December, 2007 - 6:14 pm -
The SLC5/04 does not have an Ethernet port on the CPU. That RJ45 port is a DH+ port. The...
By Bardes on 2 December, 2007 - 6:14 pm -
Think you have some kind of a ground loop. Try to isolate the fault by removing other...
By Bob Peterson on 2 December, 2007 - 6:13 pm -
5/04 plcs don't have ethernet....
from the Automation List department...
Yokogawa DCS to Modbus
Topic: Communications systems and equipment.
Originally posted by Matthew C. on 15 June, 2007 - 10:37 pm
Yokogawa communication issues
New Replies:
By Amin on 2 December, 2007 - 6:59 pm -
Dear Friends, I will be very thankful if someone could inform me for connecting DCS Yokogawa (CS...
from the Automation List department...
PLC + SCADA vs. WinPLC system
Topic: PLCs and related questions.
Originally posted by Jeff on 6 November, 2007 - 8:56 pm
We are in the middle of design for one of the most complex fish hatcheries ever to be built in North America. Our engineering consultant is recommending standard PLC and SCADA alarm and control system but one of our staff is really pushing a WinPLC based system...
New Replies:
By Andrey Romanenko on 2 December, 2007 - 6:57 pm -
In addition to Michael Griffin comments: Another application where PC are used 24x7 is model...
By Victor Robert on 2 December, 2007 - 6:54 pm -
We have had Windows 95 PC's in operation up until this year when the final one was replaced with an...
from the Automation List department...
Electric drives in so called "Test position"
Topic: Engineering and workplace issues.
Originally posted by Mikas on 30 November, 2007 - 1:19 am
Explanation of so called test position of a drive
New Replies:
By Hugo on 2 December, 2007 - 6:51 pm -
Mikas, It is not the motor that is put into the test position, it is the switchgear. There are...
from the Automation List department...
Cabling Software
Topic: Software, including programming, OS issues, etc.
Originally posted by ali fadaei on 14 August, 2005 - 5:37 pm
seeking need cad sotware that generates all documents of cabling
New Replies:
By Jerry C on 2 December, 2007 - 6:51 pm -
I am a representative of CommSYS Design LLC, and we develop CAD program for cabling systems. Our...
from the Instrumentation department...
MARK-IV Control System of GTG
Topic: Engineering and workplace issues.
Originally posted by Rajkumar Mandal on 1 December, 2007 - 1:04 am
Interfacing of Parallel Printer with MARK-IV control system.
New Replies:
By Michael Griffin on 2 December, 2007 - 6:48 pm -
In reply to CSA: You can get external serial to parallel converters (e.g. Blackbox) that are...
from the engineering department...
Micrologix or timing relay
Topic: PLCs and related questions.
Originally posted by edwardel on 1 December, 2007 - 1:16 am
Momentary pushbutton inputs to control PC digital IO
New Replies:
By Michael Griffin on 2 December, 2007 - 6:47 pm -
In reply to Tom Chubb: I think you may have a race condition with that configuration. The relay may...
from the intrumentation department...
C /C++ in PLC or in Automation
Topic: PLCs and related questions.
Posted by anonymous on 2 December, 2007 - 6:43 pm
What is ( C /C++ )in PLC or in Automation ?
from the Automation List department...
Photo sensor
Topic: Sensor technologies.
Originally posted by Darius on 5 November, 2007 - 8:38 pm
100m distance sensor
New Replies:
By Darius on 2 December, 2007 - 6:40 pm -
Is the ultrasonics sensor from siemens work at temperature up to 150C? Darius...
By Darius on 2 December, 2007 - 6:40 pm -
We will detect, whether something(products) is fall down on the floor of the drying oven. If yes,...
Topic: Communications systems and equipment.
Originally posted by Van on 26 November, 2007 - 10:59 pm
I was referred over here from www.MrPLC.com. We are developing a PC application in C/C++ and need to communicate to one or more Omron PLCs (CJ1M CPU12).
New Replies:
By Van on 2 December, 2007 - 6:17 pm -
Thank you all for your replies. Very interesting reading. In this environment, each item (PC and...
from the Automation List department...
transformer parallel operation
Topic: Engineering and workplace issues.
Originally posted by Krishna on 25 August, 2007 - 11:20 am
Is it mandatory to have same X/R ratio of the transformers meant for parallel operation apart from same %impedance, voltage ratio and vector group?
New Replies:
By PhilCorso, PE on 2 December, 2007 - 6:16 pm -
Responding to Mani's 27-Nov (00:33) problem... contact me for a Spread-Sheet solution. ...
from the Automation List department...
Mid Value Selection Scheme
Topic: Application Questions and Problems
Originally posted by P.Samuthira Pandi on 6 October, 2007 - 12:05 am
Can anyone send me the mid value selection scheme with write up for training purpose?
New Replies:
By Peter Green on 2 December, 2007 - 6:11 pm -
Please search the "Alist" Archive or "Validation of transmitter signals". ...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!