Wednesday, December 5, 2007
from the Automation List department...
PLC + SCADA vs. WinPLC system
Topic: PLCs and related questions.
Originally posted by Jeff on 6 November, 2007 - 8:56 pm
We are in the middle of design for one of the most complex fish hatcheries ever to be built in North America. Our engineering consultant is recommending standard PLC and SCADA alarm and control system but one of our staff is really pushing a WinPLC based system...
New Replies:
By Victor Robert on 5 December, 2007 - 8:57 pm -
Sorry, Curt. I didn't mean to put down the product; I don't know anything about it. Its just that...
By Curt Wuollet on 5 December, 2007 - 4:42 pm -
Just as a note: You can buy the mainboard used in the $200 WalMart PC for $60. And I don't...
from the Automation List department...
Platinum Resistance Thermometer
Topic: Continuous process industries, DCS questions.
Originally posted by jfox on 5 December, 2007 - 1:17 pm
can i use a 4 wire prt instead of a 3 wire one to do the same job?
New Replies:
By Mohammed Fawzi Kharoosa on 5 December, 2007 - 8:53 pm -
Hi What is the function for 3rd wire? It means we can use 2 wire RTD at all. As I said 4 wire...
By Mohammed Fawzi Kharoosa on 5 December, 2007 - 6:41 pm -
Three wire & Four wire sensors provide compensation for lead resistance and It depend for the: ...
By Bryce Gillan on 5 December, 2007 - 5:04 pm -
When using a 4-wire RTD, the effect of lead resistance is eliminated and has no impact on accuracy....
By Issac on 5 December, 2007 - 5:03 pm -
You're on track. Cut off the extra wire. A 4 wire RTD is a 3wire RTD with an extra wire....
from the Automation List department...
history of multimeters
Topic: Engineering and workplace issues.
Originally posted by michael egwurube on 5 December, 2007 - 5:07 pm
Can anyone point to available references?
New Replies:
By Dooley, Vince on 5 December, 2007 - 8:51 pm -
Try looking for the history of the company AVO. They were pioneers in that area. Regards Vince...
from the Engineering department...
ControlLogix Redundancy Question
Topic: PLCs and related questions.
Originally posted by Talal Hussain on 30 November, 2007 - 1:04 am
I had made redundancy in ControlLogix on hardware side but facing problem on software side
New Replies:
By Tom Tran on 5 December, 2007 - 8:38 pm -
Talal, For redundant Controllogix, you need to configure an alias topic. 1. Configure topic...
By Talal on 5 December, 2007 - 5:20 pm -
Come on Guys help me out.. The probelm is that Tag quality in Rslinx OPC test client is BAD...
from the Automation List department...
GT 9FA : Compressor Fouling Curve
Topic: Continuous process industries, DCS questions.
Originally posted by Laurent_f on 14 January, 2007 - 3:42 pm
Is it possible to draw a curve of the GT compressor's fouling with the dat you can have with dump of the memory (Mark V <I>) ?
New Replies:
By Gianluca de Arcangelis on 5 December, 2007 - 4:53 pm -
Air intake Filters are not all the same, and "best" doesn't really apply to the OEM...
from the Running Generators in paralell department...
Cross-Current Compensation Adjustment
Topic: Application Questions and Problems
Posted by Vaishakh Chavan on 5 December, 2007 - 4:52 pm
How does one adjust the cross-current compensation in paralelled alternators
from the Operations department...
GT Frame 9FA Compressor Washing
Topic: Engineering and workplace issues.
Originally posted by Kevine on 5 October, 2006 - 11:44 pm
Failure to perform GE frame 9FA Compressor Blade Wash-Mark VI Speedtronic
New Replies:
By Gianluca de Arcangelis - www.tteur.com on 5 December, 2007 - 4:52 pm -
Of course, compressor washing is required so to clean the compressor and take the output to the...
from the Automation List department...
Power Supply to the Transmitter in the Field
Topic: Engineering and workplace issues.
Posted by Anonymous on 5 December, 2007 - 4:49 pm
In the loop powered IS transmitters in the field , 24 VDC comes from DCS I/O card or the barrier?
from the Electrical department...
turbine-gen related issue
Topic: Engineering and workplace issues.
Originally posted by vedika on 5 December, 2007 - 1:39 pm
In a two gen system, two gen which were sharing equal load,one gen is disconnected and then after frequency for both reached 50hz ,gen is resynchronised in the network. so should they share same load as earlier or not?
New Replies:
By cc on 5 December, 2007 - 4:49 pm -
What type of control system are you running?...
from the Can you go to Airport Friday afternoon?? department...
Mk 6 Speedtromic Power Supply
Topic: Continuous process industries, DCS questions.
Originally posted by mike healey on 4 December, 2007 - 9:58 am
What to do with an old power supply?
New Replies:
By CSA on 5 December, 2007 - 4:44 pm -
I believe GE has a repair-and-return option for most of their Speedtronic equipment....
from the Serious department...
Telemecanique Safety Relay, XPS-AT
Topic: Application Questions and Problems
Originally posted by Tim J on 18 March, 2002 - 3:28 pm
Noise? or What to look for?
New Replies:
By Norman Bourne on 5 December, 2007 - 4:39 pm -
Hi Brian, I have had a problem with a Telemecanique Safety relay, and whilst browsing the web,...
Topic: Human-Machine Interface and SCADA.
Originally posted by Jim Tompkins on 1 March, 2002 - 6:05 pm
I am looking for a graphical editor or active-x based MMI package that I can use in conjunction with Visual Basic and/or Visual C++...
New Replies:
By CSTSOFT on 5 December, 2007 - 4:38 pm -
Very good graphic designer, you should take a look. http://www.cstsoft.com...
from the control department...
gas turbine control system
Topic: Information resources, documentation.
Originally posted by Anonymous on 4 December, 2007 - 9:50 am
i need book about gas turbine control system frame 9 and MARK-V
New Replies:
By CSA on 5 December, 2007 - 2:02 pm -
Umm, have you looked in the instruction manuals provided with the turbine-generator by the packager...
from the Automation List department...
PLC C40H problem
Topic: PLCs and related questions.
Posted by borce on 5 December, 2007 - 1:55 pm
communication problem
from the MAINTENANCE department...
Bad Communication on Modbus
Topic: Communications systems and equipment.
Originally posted by DAMENE on 4 December, 2007 - 9:59 am
Help me to find the communication problem DCS MARK 5 over MODBUS
New Replies:
By dchartier on 5 December, 2007 - 1:53 pm -
Hello Damene; First checking the cabling is a good start, but not the only one. Modbus...
from the Automation List department...
WEG devices and MODBUS/RTU
Topic: Computers in manufacturing; also hardware discussion.
Originally posted by Alejandro on 3 December, 2007 - 11:53 pm
I have Frequency Inverters and Soft-Starters from WEG. They are MODBUS/RTU capable, and I started to link them to the computer through RS485 network.
New Replies:
By Alejandro Farre on 5 December, 2007 - 1:52 pm -
I suppose no one is familiar with this type of devices from WEG? What about any device like...
from the Automation List department...
Battery on C40H PLC
Topic: PLCs and related questions.
Posted by borce on 5 December, 2007 - 1:47 pm
changing battery
from the XP with TwinCAT department...
TwinCAT
Topic: Computers in manufacturing; also hardware discussion.
Posted by Srini on 5 December, 2007 - 1:45 pm
To control Parallel port with TwinCAT
from the Automation List department...
AC Servo motor controls
Topic: Motion control, servos, steppers, etc.
Originally posted by Rick B on 4 December, 2007 - 6:03 pm
Question about AC servo motor drives
New Replies:
By Curt Wuollet on 5 December, 2007 - 1:44 pm -
Most drives will handle "foreign" motors if you have the data for the motor and they are...
By William Sturm on 5 December, 2007 - 1:43 pm -
Some drives can be configured for other motors, but many cannot. A-B Ultra 100, many Baldor, and...
By Ken Emmons Jr. on 5 December, 2007 - 1:43 pm -
If this is the typical permanent magnet servo with hall switch commutation and incremental encoder,...
Topic: Engineering and workplace issues.
Posted by turbino on 5 December, 2007 - 1:40 pm
Control for a boiler feedwater system which is to continously supply feedwater at 240 psig to a steam turbine plant.
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.