Thursday, December 13, 2007
from the INSTRUMENT department...
Mark IV trouble on auxiliary transformer (UAT)
Topic: Engineering and workplace issues.
Originally posted by nanang on 13 December, 2007 - 12:07 am
My company uses Mark IV to control Gas Turbine Generator (GTG). It's often got trip caused by Unit Auxiliary Transformer (UAT) when the unit goes online. What possible things can I do to solve this problem?
New Replies:
By CSA on 13 December, 2007 - 2:02 am -
When you say the unit trips because of the UAT, how does the UAT trip the unit? Is it through a...
from the Automation List department...
PLC + SCADA vs. WinPLC system
Topic: PLCs and related questions.
Originally posted by Jeff on 6 November, 2007 - 8:56 pm
We are in the middle of design for one of the most complex fish hatcheries ever to be built in North America. Our engineering consultant is recommending standard PLC and SCADA alarm and control system but one of our staff is really pushing a WinPLC based system...
New Replies:
By Michael Griffin on 13 December, 2007 - 2:00 am -
In reply to William Sturm: The following is a bit of a long story, but I think the background is...
from the Automation List department...
MkV FSR acceleration control
Topic: Application Questions and Problems
Originally posted by Slavik Logvin on 19 October, 2006 - 12:24 am
We have GE MS5002B (regenerative cycle) gas turbines with Mark V control system. During startup we have problems with flame stability (sometimes loss of flame)...
New Replies:
By harith akram on 13 December, 2007 - 1:58 am -
To avoid loss of flame, reduce the turbine warmup time (K2W) to reach turbine to acceleration speed...
from the Automation List department...
Pneumatic controller
Topic: Engineering and workplace issues.
Originally posted by turbino on 11 December, 2007 - 1:57 am
Pneumatic controller used for steam turbine driven feedwater pump's control valve, which controls the pump speed from the pressure setting corresponding to feedwater pressure?
New Replies:
By turbino on 13 December, 2007 - 1:58 am -
First off, thanks for your response. Yes, I do have a bit of gray hair, but my age has nothing to...
Topic: Engineering and workplace issues.
Originally posted by Anonymous on 29 April, 2007 - 12:51 pm
What is the effect of water injection in Gas Turbine on Efficiency
New Replies:
By CSA on 13 December, 2007 - 1:56 am -
GE, of course. Wood Group. TTS. To name a few....
from the control department...
Accelaration FSR
Topic: Application Questions and Problems
Originally posted by any one on 11 December, 2007 - 10:57 pm
How can I reduce the acceleration time and increase the rate of FSR in turbine ms9001e?
New Replies:
By CSA on 13 December, 2007 - 1:53 am -
Reducing the acceleration comes at a cost--to the hot gas path parts life. The air flow through the...
from the Maintenance department...
Combustion Trouble
Topic: Application Questions and Problems
Originally posted by ge_user on 27 January, 2007 - 3:07 pm
Combustion Trouble alarm during higher load
New Replies:
By Ray on 13 December, 2007 - 1:49 am -
The control system is a Allen-Bradley solid state system. We did find two T/Cs that were bad,...
from the Efficiency? department...
Reversible motor or alternator?
Topic: Engineering and workplace issues.
Posted by Owen on 13 December, 2007 - 1:42 am
Why are alternators used over DC motors to produce electricity?
from the Automation List department...
Modbus connection
Topic: Local and wide area networking in factory automation.
Posted by electron on 13 December, 2007 - 1:39 am
Connection with SCADA protocol translator ASE SPT4-NET with convertor mi400/rts rs232/rs485
from the Automation List department...
Modbus TCP function for PHP
Topic: Communications systems and equipment.
Originally posted by Volzon on 11 December, 2007 - 10:59 pm
I'm making a logging function on a Linux system.
I need a PHP function to read from a PLC using Modbus TCP. Or another way of reading data from Modbus TCP an placing it in a MySQL database.
New Replies:
By Michael Griffin on 13 December, 2007 - 1:20 am -
Is the web server going to be located at the PLC, or is it supposed to be located somewhere else...
By Paul Wacker on 13 December, 2007 - 12:59 am -
If you're OK with using Perl, it looks like there's a module available. It wouldn't be too...
from the Automation List department...
PM9C Voltage Scaling
Topic: Communications systems and equipment.
Originally posted by C2k on 6 December, 2007 - 10:02 pm
How to convert raw values to engineering units
New Replies:
By Michael Griffin on 13 December, 2007 - 1:11 am -
The input should be calibrated such that full scale is some known value (volts or millivolts), and...
from the Automation List department...
AC Servo motor controls
Topic: Motion control, servos, steppers, etc.
Originally posted by Rick B on 4 December, 2007 - 6:03 pm
Question about AC servo motor drives
New Replies:
By Leonid on 13 December, 2007 - 1:07 am -
I think that you need 2-axis motion controller for axes synchronization and analog servo amps with...
from the Automation List department...
Citect to Twido Communication
Topic: Communications systems and equipment.
Posted by Guillermo on 13 December, 2007 - 1:04 am
Can somebody connect Twido with Citect?
from the Automation List department...
Frame 5 Run vs. Down Time
Topic: Continuous process industries, DCS questions.
Posted by Ray on 13 December, 2007 - 1:03 am
Frame 5 14MW Gas Turbine--how long to wait between shutdown after a run and starting new run?
from the Electrical department...
MSG SLC500 to PLC5
Topic: PLCs and related questions.
Posted by PPS on 13 December, 2007 - 1:01 am
MSG SLC500 to PLC5
from the interface department...
AC800M interface with GCOM
Topic: Communications systems and equipment.
Originally posted by Paulo on 31 October, 2007 - 10:53 pm
AC800M possible interface with legacy ABB products. (MB300, GCOM)
New Replies:
By Anonymous on 13 December, 2007 - 1:00 am -
Hello, I have another question for you, Paulo. What are you using GCOM for? I'm very interested...
from the C&I department...
Variable frequency drives
Topic: Application Questions and Problems
Originally posted by Arvind Joshi on 12 December, 2007 - 12:16 am
Permissible input frequency variations by VFDs available.
New Replies:
By Mike McLeod on 13 December, 2007 - 1:00 am -
Arvind, Naturally, you will need to speak with representatives from some of the manufacturers of...
from the Automation List department...
Tuning Of Loops With Large Process:Dead Time Ratios
Topic: Continuous process industries, DCS questions.
Originally posted by GPN on 9 December, 2007 - 5:33 pm
I was interested to know others opinions on tuning of loops with large process time constants and small dead time's. These cause the Tp/Td ratio to be quite large, hence causing very large Kc when using the Z-N method's.
New Replies:
By Peter Nachtwey on 13 December, 2007 - 12:57 am -
Why didn't you stick with the IMC gains? They will work. I didn't reply before because I thought...
By Bruce Durdle on 13 December, 2007 - 12:01 am -
Aha - you have an interactive process. Temperature is usually very slow and noise-free, so can...
from the Third party HMI for Symax in late 80's department...
SquareD Symax HMI
Topic: Human-Machine Interface and SCADA.
Posted by Tom Vaughan on 13 December, 2007 - 12:55 am
Trying to remember...
from the Wireless department...
Cellular Modem
Topic: Communications systems and equipment.
Originally posted by R on 11 December, 2007 - 2:25 am
Has anyone tried Cellular Modems?
New Replies:
By Paul Wacker on 13 December, 2007 - 12:54 am -
I would recommend you consider AirLink (who is now part of Sierra Wireless). They have a number of...
from the Automation List department...
Telemecanique
Topic: Human-Machine Interface and SCADA.
Posted by Tiago Monteiro on 13 December, 2007 - 12:49 am
Cable connection XBTG 2110 to PC
from the Instrumentation & Control department...
Fieldbus control loop limitation
Topic: Continuous process industries, DCS questions.
Originally posted by Lorenzo Cecchini on 6 December, 2007 - 10:04 pm
The Fieldbus real limitation is within the scan time?
New Replies:
By Jonas Berge on 13 December, 2007 - 12:15 am -
It is not limited to one loop per bus. You can have many loops per bus, even for fast loops. UOP...
from the Automation List department...
Discrete I/O and Fieldbus
Topic: Continuous process industries, DCS questions.
Originally posted by Hamid on 7 October, 2007 - 11:54 am
Finding a solution for expensive D-I/O for Foundation Fieldbus
New Replies:
By Jonas Berge on 13 December, 2007 - 12:15 am -
The original post from Carmel was onto something. Use Foundation fieldbus for...
from the Automation List department...
TXP sytem
Topic: Application Questions and Problems
Originally posted by fahad on 17 November, 2007 - 10:04 pm
using SQL in TXP ES680
New Replies:
By GP on 13 December, 2007 - 12:11 am -
Please repeat your question, however check what it is you write down before you post it. I will...
from the GSM modems in conjunction with OPC Servers department...
SCADA Alarm Messaging
Topic: Human-Machine Interface and SCADA.
Originally posted by Chris Signorelli on 22 April, 2005 - 9:49 am
Need advice on suitable software and GSM modem that can send SMS messages to mobile phone upon OPC Alarm tag.
New Replies:
By Cinzia La Morgia on 13 December, 2007 - 12:10 am -
Did you try SMS Server? SMS Server is a add-on for CitectSCADA that lets you to notify via SMS...
from the Automation List department...
kVAR sharing of gensets
Topic: Engineering and workplace issues.
Posted by Dave on 13 December, 2007 - 12:08 am
What should be the current flowing in the secondary of the droop control CT?
from the not very clear in the manual department...
Monitor Pro (Factorylink) IML execution sequence
Topic: Application Questions and Problems
Originally posted by Buzby on 24 April, 2007 - 2:00 am
Are IML procedures ever interrupted by other IML procedures?
New Replies:
By olivier chesnais on 13 December, 2007 - 12:06 am -
He discovered strange behavior of his system. It looks like the problem comes from IML task...
from the candi department...
SA85
Topic: PLCs and related questions.
Posted by senya on 13 December, 2007 - 12:03 am
SA85 hardware installation
Topic: Software, including programming, OS issues, etc.
Posted by Sambhaji on 13 December, 2007 - 12:02 am
Implementation of ModbusRTU over RS485 (2 Wire) using Rabbit3000 processor.
from the Instrumentation department...
pH Sensor and pH Transmitter
Topic: Engineering and workplace issues.
Posted by Kaustubh on 13 December, 2007 - 12:01 am
Use of ABB pH Sensor with Foxboro pH Transmitter.
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.