Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
Goldenstern's Rules:
(1) Always hire a rich attorney
(2) Never buy from a rich salesman.
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Sunday, December 16, 2007
from the Are there any decent ones anywhere??? department...
PL7 Pro guide for using bridging and FIP, etc.
Topic: PLCs and related questions.
Originally posted by Graeme Sayer on 19 October, 2007 - 1:13 am
I'd like to be able to assist vendors with setting up the PLCs
New Replies:
By Stephen Hoste on 16 December, 2007 - 9:02 pm -
Bridging in Telemechanique is quite straightforward, given a couple of pointers. If you are still...
from the Automation List department...
Platinum Resistance Thermometer
Topic: Continuous process industries, DCS questions.
Originally posted by jfox on 5 December, 2007 - 1:17 pm
can i use a 4 wire prt instead of a 3 wire one to do the same job?
New Replies:
By shiraz on 16 December, 2007 - 8:18 pm -
The hardware is HP34970A thanks....
from the Automation List department...
manometer
Topic: Engineering and workplace issues.
Posted by sanse on 16 December, 2007 - 8:17 pm
how to use the u shape manometer for pressure callibration
from the Automation List department...
Re: Why do you pay for PLC programming software?
Topic: PLCs and related questions.
Originally posted by William Sturm on 5 May, 2007 - 2:45 am
Empty summary
New Replies:
By Jeremy Pollard on 16 December, 2007 - 8:16 pm -
I concur. There are many features that ICOM WinLogix and AI software had that is still not in...
from the Projects department...
Use of RTC Address in SLC 5/03
Topic: PLCs and related questions.
Originally posted by 3DMS on 15 December, 2007 - 2:50 pm
How could we use the RTC addresses in the SLC 5/03?
New Replies:
By Jeremy Pollard on 16 December, 2007 - 6:43 pm -
The RTC in an SLC is embedded in the status file .. check the S data table file and it will be on...
By Bob Peterson on 16 December, 2007 - 5:47 pm -
the rtc in a 5/03 is in the status file (s2)....
from the Automation List department...
S7 - software redundancy
Topic: PLCs and related questions.
Originally posted by H.Hassona on 14 December, 2007 - 12:41 am
Redundant S7-315-2DP... Is it right to leave OB1 empty and put all the code in OB35?
New Replies:
By Mark Bayern on 16 December, 2007 - 6:39 pm -
Why not use OB35 for the loops that require a cyclic interrupt, and use OB1 for the loops and...
from the Automation List department...
LIquid Fuel Problem on Gas Turbine Generator
Topic: Engineering and workplace issues.
Originally posted by nanang on 15 December, 2007 - 2:59 pm
the type of gas turbine is MS 9001E, with load capacity 100 MW, and using MARK IV as a controller...
New Replies:
By CSA on 16 December, 2007 - 6:37 pm -
You need to have someone who can read and understand schematic piping diagrams (piping &...
from the Automation List department...
Networking Hirschmann Ethernet
Topic: Application Questions and Problems
Posted by Shams Naqvi on 16 December, 2007 - 6:36 pm
looking for two Hirschmann RS2-4R-2MM SC switches for a demo of our system...
from the INSTRUMENT department...
Mark IV trouble on auxiliary transformer (UAT)
Topic: Engineering and workplace issues.
Originally posted by nanang on 13 December, 2007 - 12:07 am
My company uses Mark IV to control Gas Turbine Generator (GTG). It's often got trip caused by Unit Auxiliary Transformer (UAT) when the unit goes online. What possible things can I do to solve this problem?
New Replies:
By CSA on 16 December, 2007 - 6:34 pm -
You need to find help from someone who can read the drawings and understand what causes the UAT to...
from the Automation List department...
Temperature Transmitter Calibration
Topic: Application Questions and Problems
Originally posted by Bill Code on 14 December, 2007 - 1:08 am
Min/max limits of temperature transmitters
New Replies:
By tc on 16 December, 2007 - 5:49 pm -
J type thermocouple measure 0-700c normly but in short term it can handle -50 to 2000c .but dear ur...
from the Automation List department...
Pelco D/P Protocol
Topic: Engineering and workplace issues.
Originally posted by Max on 12 December, 2004 - 11:31 pm
I need to know the Pelco D/P Protocol.
New Replies:
By Faustino Galan on 16 December, 2007 - 5:48 pm -
I have a system with 2 PTZ cameras, 2 DVRs and a non Pelco keyboard. Is there a way that I can have...
from the Automation List department...
Comparison between ASI, Fieldbus and Profibus
Topic: Application Questions and Problems
Originally posted by zare.v on 15 December, 2007 - 2:12 am
I need some information to compare the mostly used bus-based systems such as ASI, Profibus, Fieldbus.
New Replies:
By Jonas Berge on 16 December, 2007 - 5:40 pm -
Take a look at this article first: ...
By zare.v on 16 December, 2007 - 5:39 pm -
Mr. Daniel, Thank you for your concern. Since I can not access to the link(PDF file) which you...
from the Automation List department...
Writing data from RSView SE to an XLS file using VBA
Topic: Human-Machine Interface and SCADA.
Originally posted by Carlos Cordova on 8 July, 2007 - 9:06 pm
I'm trying to make a VBA code capable of taking a tag from RSView SE and then write it into a XLS file...
New Replies:
By sreeraj on 16 December, 2007 - 5:37 pm -
hi I have tried this one by configuring DDE client that comes along with RsLinx long ago.I dont...
from the control department...
accelaration fsr
Topic: Application Questions and Problems
Posted by any one on 16 December, 2007 - 5:21 pm
reduce acceleration time with increasing fsr
from the Automation List department...
Discrete I/O and Fieldbus
Topic: Continuous process industries, DCS questions.
Originally posted by Hamid on 7 October, 2007 - 11:54 am
Finding a solution for expensive D-I/O for Foundation Fieldbus
New Replies:
By Jonas Berge on 16 December, 2007 - 5:21 pm -
1. ASI is a bus protocol (not a control system) http://www.as-interface.com/ ASI connects to...
from the serious department...
control of boiler drum with honeywellUDC 6300
Topic: Continuous process industries, DCS questions.
Posted by kannan on 16 December, 2007 - 2:16 pm
I want to put back the UDC 6300 with good config to control the drum level. All the inputs are 4-20 ma the output is a 4-20 ma controlling Pne.valve throu I/P. The transmitters are DP for the flow as well as for the level.
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.