Wednesday, December 19, 2007from the Automation List department...
Re: Brick PLCsI am curious if others have had problems with Micrologix PLCs being really touchy about AC power...
from the Automation List department...
Re: Resolution of analog inputWhat would be the voltage resolution on an analog input of 16 bit resolution?
from the Automation List department...
Re: Why are alternators chosen over DC motors to produce power?Which would produce the power most efficiently, an alternator and a DC motor?
from the Automation List department...
Motorola Moscad/ACE to Modbus SlaveMoscad/ACE reads Holding Register Values from Slave device using MODBUS. What's the maximum number for 3xxxx?
from the Automation List department...
Re: S7 - software redundancyRedundant S7-315-2DP... Is it right to leave OB1 empty and put all the code in OB35?
from the Automation List department...
Re: LIquid Fuel Problem on Gas Turbine Generatorthe type of gas turbine is MS 9001E, with load capacity 100 MW, and using MARK IV as a controller...
from the Automation List department...
Re: CCC and DCSAdvantage to use CCC or DCS
from the tigger department...
GE MarkV HMIProblems with HMI freezing when getinf data via modbus serial comms
from the Automation List department...
Re: Brick PLCsI am curious if others have had problems with Micrologix PLCs being really touchy about AC power...
from the software training department...
Re: power system analysis softwareseeking training on power system analysis software
from the Automation List department...
Bailey ALSPA-ZS communication to HMIIs there a way to get read/write date to/from ALSPA-ZS?
from the inst department...
DCS and SERDCS built-in sequence of events recorder (SER) vs. stand alone SER
from the Automatization in proccess control department...
Siemens's web4txp versionSiemens's web4txp version which supports DHCP.
from the Please Help----URGENT!!! department...
Re: Java j2ee training in Bangalore and KolkataJava J2ee training in Kolkata and Bangalore with Live Project and Placement Opportunities...
from the Automation List department...
Re: Distributed control system trainingI would like to get details on DCS Yokogawa training in Banglore.
from the Automation List department...
Re: 4-20mA conversionI'm looking to convert 4-20mA to a digital signal
from the Automation List department...
Re: Boiler Feedwater Pump Control in Steam-powered Pumping StationControl for a boiler feedwater system which is to continously supply feedwater at 240 psig to a steam turbine plant.
from the Automation List department...
Re: 4-20mA conversionI'm looking to convert 4-20mA to a digital signal
from the Automation List department...
Re: Modbus TCP function for PHPI'm making a logging function on a Linux system.
I need a PHP function to read from a PLC using Modbus TCP. Or another way of reading data from Modbus TCP an placing it in a MySQL database.
I need a PHP function to read from a PLC using Modbus TCP. Or another way of reading data from Modbus TCP an placing it in a MySQL database.
from the Automation List department...
Problems with Magelis XBTGT 6330Problem to download to Magelis XBTGT 6330
from the analog input department...
Resolution of analog inputWhat would be the voltage resolution on an analog input of 16 bit resolution?
from the Automation List department...
GSM/MODBUS vs. PROFIBUSWhat are the advantages and disadvantages between GSM/MODBUS over PROFIBUS?
from the Automation List department...
Re: Teleperm XP ArchivingTXP archiving.
from the Automation List department...
Re: About INtools and INSTRUCALCINtools and INSTRUCALC
from the Electrical department...
GT generator hydrogen purity dropGT generator hydrogen purity drop
from the Automation List department...
Re: 4-20mA conversionI'm looking to convert 4-20mA to a digital signal
from the process department...
How to reduce scrapHow to reduce scrap after cutting process.
from the Electrical department...
Relation of P, f, V and A in Generation SystemGrid System
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.