from the Automation List department...
Re: MKV Simplex Problems
HMI topic
Reply posted by Danno on 4 March, 2008 - 6:49 pm
MKV Issues/Alarms
from the too cheap to buy the whole roll department...
Looking for cable by the foot
Information topic
Posted by Jerry on 4 March, 2008 - 6:49 pm
Where can I buy cable and wire without buying the whole roll?
PLCs topic
Reply posted by Erik Syme on 4 March, 2008 - 6:48 pm
Prosoft Modbus communication modules for Allen Bradley like MVI56-MCM cause timout problems on multiple slaves RS-485 multipdrop network if slaves are powered off or faulty...
from the Automation List department...
associating activex control with a control tag
PLCs topic
Posted by venu on 4 March, 2008 - 4:47 pm
RS VIEW
from the Automation List department...
Re: EEx ia vs EEx [ia] vs [EEx ia]
Engineering topic
Reply posted by Bruce Durdle on 4 March, 2008 - 4:46 pm
Can anyone tell me what difference between EEx ia and EEx [ia] and [EEx ia]?
PLCs topic
Reply posted by Hugo Ahrens on 4 March, 2008 - 4:40 pm
Prosoft Modbus communication modules for Allen Bradley like MVI56-MCM cause timout problems on multiple slaves RS-485 multipdrop network if slaves are powered off or faulty...
from the Automation List department...
Re: Selecting diaphragm seal type for pressure tansmitter
Engineering topic
Reply posted by JIM on 4 March, 2008 - 4:38 pm
I intend to select diaphragm seal for pressure transmitter and i have found that there is special seal type called pancake type diaphragm seal...
from the Automation List department...
Early 90's Motion Control
Motion Control topic
Posted by Jeremy Pollard on 4 March, 2008 - 3:53 pm
on the prowl for motion boards or co-processor board DDE servers - like version 1.0...
from the Automation List department...
Re: RSLogix 500 SLC 5/03 Watchdog problem...
PLCs topic
Reply posted by Michael Griffin on 4 March, 2008 - 3:52 pm
I have a problem with the SLC 5/03 watchdog timer expiring...
from the control department...
Re: control system for compressor
PLCs topic
Reply posted by Jos on 4 March, 2008 - 3:50 pm
upgrading for old control system
from the Automation List department...
Re: GE Panametrics Humidity Sensor Calibration : M2LR
Information topic
Reply posted by CSA on 4 March, 2008 - 3:50 pm
Who in India calibrates M2LR Probes?
from the Automation List department...
Re: EEx ia vs EEx [ia] vs [EEx ia]
Engineering topic
Reply posted by Seetharam on 4 March, 2008 - 3:48 pm
Can anyone tell me what difference between EEx ia and EEx [ia] and [EEx ia]?
PLCs topic
Posted by e105 on 4 March, 2008 - 3:47 pm
Prosoft Modbus communication modules for Allen Bradley like MVI56-MCM cause timout problems on multiple slaves RS-485 multipdrop network if slaves are powered off or faulty...
from the DCS department...
Re: Teleperm XP Archiving
Process Control topic
Reply posted by cavi on 4 March, 2008 - 9:51 am
TXP archiving.
from the automation department...
Re: PLC programming CQM1H
PLCs topic
Reply posted by vahid on 4 March, 2008 - 9:51 am
Looking for programming PLC using CQM1H
from the Automation List department...
Storms SCADA???
PCs in Automation topic
Posted by woo on 4 March, 2008 - 9:49 am
Did anybody heard about STORMS SCADA software?
from the Automation List department...
RSLogix 500 SLC 5/03 Watchdog problem...
PLCs topic
Posted by Warren Boswell on 4 March, 2008 - 9:29 am
I have a problem with the SLC 5/03 watchdog timer expiring...
Information topic
Posted by IG_Plant on 4 March, 2008 - 9:29 am
Who in India calibrates M2LR Probes?
from the Automation List department...
o2 analyzer and so2 or h2s analyzer
Information topic
Posted by sara on 4 March, 2008 - 9:28 am
I'd like to get some useful information about o2 analyzer and so2 or h2s analyzer...
from the Automation List department...
Re: Rexroth A4VS40DR axial piston hydraulic pump
Motion Control topic
Reply posted by Greg Adams on 4 March, 2008 - 9:28 am
I have a Rexroth A4VS40DR axial piston hydraulic pump with a low output pressure.
from the RC mower Saga department...
RC Motor controller
Applications topic
Posted by Me on 4 March, 2008 - 9:28 am
Where are all the reasonably price sources?
from the Automation List department...
Re: Rockwell String DataType
Software in Automation topic
Reply posted by Michael Griffin on 4 March, 2008 - 9:27 am
Does anyone know of a way to reduce the word/character count?
from the Automation List department...
Re: Fieldbus or DCS
Software in Automation topic
Reply posted by Syed Aftab Ahmed on 4 March, 2008 - 9:24 am
Which would prove to be better solution for Ammonia plant?
from the Automation List department...
Re: Frequency and Voltage
Applications topic
Reply posted by Curt Wuollet on 4 March, 2008 - 9:23 am
what is the relation between frequency and voltage?
from the AAARRRGGGHHH!!!!!!!! department...
Re: Step 7 Install Hangs
Software in Automation topic
Reply posted by Roy Matson on 4 March, 2008 - 9:21 am
annoying install hang that even has the Siemens hotline guys stumped
from the electrical department...
Re: Selection of Telemecanique Products for SCADA
Communications topic
Reply posted by MikeD on 4 March, 2008 - 9:20 am
can i use twido plc to connnect to telemetry radio that has a serial interface.
from the Automation List department...
Re: Mk 6 Alarms List
HMI topic
Reply posted by CSA on 4 March, 2008 - 9:19 am
Anyone familiar with MK6 alarms lists? Mk6 Simplex running an LM6000 SAC GT
from the Automation List department...
Re: Modification of Steam Turbine
Engineering topic
Reply posted by CSA on 4 March, 2008 - 9:17 am
We have two 80MW Steam Turbines of Alstom make. We want to perform a modification that if one ESV closes during normal operation, our Steam turbine keep running with one ESV
from the Automation List department...
Re: MKV Simplex Problems
HMI topic
Reply posted by CSA on 4 March, 2008 - 9:15 am
MKV Issues/Alarms
from the Automation List department...
Re: MKV Simplex Problems
HMI topic
Reply posted by Danno on 4 March, 2008 - 9:13 am
MKV Issues/Alarms
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, PostgreSQL and Apache. Be happy.

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!