Posts from...
Sunday, April 27, 2008
from the Automation List department...
Re: Mark 5 scale type
Applications topic
Reply posted by Radhakrishnan on 28 April, 2008 - 12:31 am
Please help me to understand the meaning of scale type (CIM, CIM_I)
from the C&I maintenance department...
CCC speed controller series 3+
Engineering topic
Posted by ngocvovan on 28 April, 2008 - 12:31 am
CCC speed controller series 3+ generates alarm: I/H failure and I/P failure at the same time for no reason.
from the looking for a programmer! department...
Paragon 550
Process Control topic
Posted by me on 28 April, 2008 - 12:29 am
I need to upgrade Paragon 550 implementation controling a chemical reactor.
from the Automation List department...
Re: data link failure between DCS OVATION and SIEMENS PLC
Communications topic
Reply posted by dasf on 28 April, 2008 - 12:25 am
there is no communication between DCS and PLC
from the Engineering department...
Re: Yorkshire Switch gear YSF6
Engineering topic
Reply posted by Paul Bingham on 28 April, 2008 - 12:24 am
I need user manual or any technical drawings regarding Yorkshire YSF6 circuit breaker 11KV,630A
from the PLC MAINTENANCE department...
Re: S7 PLC200
PLCs topic
Reply posted by dchartier on 28 April, 2008 - 12:24 am
Could anybody add S7 200 PLC?
from the PLC MAINTENANCE department...
Re: S7 PLC200
PLCs topic
Reply posted by zahid ali khan on 28 April, 2008 - 12:21 am
Could anybody add S7 200 PLC?
from the Automation List department...
Woodward Governor Control 505
Motion Control topic
Posted by Gopal on 28 April, 2008 - 12:21 am
Woodward Governor Control 505 switching from remote SP to local on what conditions?
from the chemical engineering department...
Anti-caking agent in urea plant
Engineering topic
Posted by Hussain Al Musawa on 28 April, 2008 - 12:20 am
UF-85 Urea formyldehyde chemical
from the Modbus department...
Twido PLC Modbus Mapping
PLCs topic
Posted by farooq on 28 April, 2008 - 12:16 am
How to move inputs i0.16 to i0.23 to a memory word with a single operation block?
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.