Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
The steady state of disks is full.
-- Ken Thompson
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Sunday, July 13, 2008
from the ETR Diagnostic alarms department...
'TCE1 TMR check trouble, ETR2' alarm
Topic: Engineering and workplace issues.
Originally posted by Brian on 12 July, 2008 - 1:02 am
1697 ;TCE1 TMR check trouble, ETR2 diagnostic alarm is appearing when the unit is running.
New Replies:
By CTTech on 13 July, 2008 - 11:13 pm -
I would use the PD core to remove power from each TCEA core ie X, Y, and Z and observe R, S, and T...
By Brian on 13 July, 2008 - 12:17 pm -
Thanks for your reply, the above alarm was rectified after changing the TCEA card of the <S>...
from the Program hangs requiring reboot department...
RSVies32 VBA app
Topic: Human-Machine Interface and SCADA.
Originally posted by Don on 13 July, 2008 - 10:02 pm
RSView app hangs *sometimes* when trying to call vba subroutine
New Replies:
By Trevor Ousey on 13 July, 2008 - 11:12 pm -
G'day Don, I would be careful using VBA as a popup, it is not recommended in RSView32. I would...
By CTTech on 13 July, 2008 - 11:11 pm -
It is all about focus. The alarm changes focus! .focus...
from the Automation List department...
How to document/model a PLC based project?
Topic: Engineering and workplace issues.
Originally posted by Tom Reaney on 12 July, 2008 - 5:25 pm
I propose using the waterfall model of software development (shows my age) ...
New Replies:
By Don on 13 July, 2008 - 11:10 pm -
I've had pretty good luck with Unitronics Vision series PLC/HMI for small applications. The units...
By Michael Griffin on 13 July, 2008 - 12:05 pm -
To answer your questions in turn: 1) An "industry standard representation" flowchart...
from the serious department...
embedded system training in bang
Topic: Information resources, documentation.
Originally posted by suseela on 19 August, 2005 - 4:44 pm
Part-time embedded training
New Replies:
By Ravi on 13 July, 2008 - 11:09 pm -
Hai, Dhanyath infosystem is given training on emebedded system& networking, project are based...
from the Automation List department...
KVM Extender with Fiber optic
Topic: Application Questions and Problems
Posted by Nanda on 13 July, 2008 - 11:09 pm
need KVM Extender with Fiber optic rated for Class I div II...
from the Help department...
modbus with DCS-CS30000 or foxboro
Topic: Communications systems and equipment.
Posted by PC on 13 July, 2008 - 10:06 pm
scanning of bits for modbus with DCS-CS30000 or foxboro
from the Automation List department...
Feedforward and Cascade Controls
Topic: Continuous process industries, DCS questions.
Originally posted by Prasad on 12 July, 2008 - 1:46 am
Differentiate between cascade controller and feedforward mechanism
New Replies:
By George Buckbee on 13 July, 2008 - 10:01 pm -
You can find recorded webinars on Cascade, Feedforward, and more at ...
from the Automation List department...
AB Wintelligent hardware compatability
Topic: Human-Machine Interface and SCADA.
Originally posted by Don on 11 July, 2008 - 1:31 am
Is AB PKTX card compatible with Wintelligent?
New Replies:
By Don on 13 July, 2008 - 10:01 pm -
I also have a need to upgrade the hardware on some InTouch systems for similar reasons, i.e,...
from the Automation List department...
S7 vs ControlLogix
Topic: PLCs and related questions.
Originally posted by Scott on 3 March, 2004 - 6:17 pm
I am currently looking at upgrading some old S5 PLCs.
New Replies:
By DT on 13 July, 2008 - 9:59 pm -
I am not here to defend ControlLogix, in fact, my stance is "you may find a better product,...
from the Department Department department...
FIX DMACS Software
Topic: Human-Machine Interface and SCADA.
Originally posted by Bagoes on 12 July, 2008 - 10:43 am
Need FIX DMACS Development software, please help!!
New Replies:
By Bob Peterson on 13 July, 2008 - 9:59 pm -
iFix (or Fix Dynamics) is not really an upgrade to any of the previous Fix versions. It is really a...
By Burnikell on 13 July, 2008 - 12:07 pm -
Hi Bagoes, It's been a while since I used Intellutions FIX products but here is what I recall. ...
from the Speedtronic department...
MKIV - Laptop interface
Topic: Engineering and workplace issues.
Posted by Dhinesh on 13 July, 2008 - 12:18 pm
MKIV to Laptop communication to capture data from the MKIV panel
from the Automation List department...
4-20 mA pressure transmiiter low insulation
Topic: PLCs and related questions.
Originally posted by toper on 12 July, 2008 - 5:09 pm
pressure transmitter 4-20 mA output when connected to plc system showing low insulation alarm in the UPS panel.
New Replies:
By Roy Matson on 13 July, 2008 - 12:18 pm -
Your 24 VDC is likely grounded at some point. I suspect at the PLC - 24VDC (on purpose). The UPS...
from the Instrumentation department...
Load Cell signal Cable
Topic: Continuous process industries, DCS questions.
Originally posted by Arun Meyyappan on 12 July, 2008 - 5:11 pm
Can an ordinary 1.00 Sq.mm Signal Cable be used for transmission of Load cell Output?
New Replies:
By Roy Matson on 13 July, 2008 - 12:17 pm -
For a typical cell your cable should be shielded with 6 wires (3 pair) Pair 1 from the control...
from the Automation List department...
Configuring kepware OPC for Mark VI
Topic: Communications systems and equipment.
Posted by Anonymous on 13 July, 2008 - 12:16 pm
Can anyone tell me how?
from the Electrical department...
Requiring Transformer Design books online
Topic: Engineering and workplace issues.
Posted by Anonymous on 13 July, 2008 - 12:15 pm
Any body can tell me about the sites for transformer design books online for free
from the Automation List department...
DB block access in slave 315-2DP
Topic: Communications systems and equipment.
Posted by Mark on 13 July, 2008 - 12:14 pm
Possibility of DB block access in 315-2DP form WAGO IPC controller
from the Maintenance department...
Overload setpoint
Topic: Motion control, servos, steppers, etc.
Originally posted by Greg Adams on 26 June, 2008 - 12:18 am
How to determine motor overload setpoint on relay that monitors I/E phase shift?
New Replies:
By jojo on 13 July, 2008 - 12:14 pm -
You never find a motor that is exactly 'tuned' to the environment that it is working in....
from the Automation List department...
Consulting vs. Manufacturing Employment Advice
Topic: Continuous process industries, DCS questions.
Originally posted by Jud Wooters on 2 July, 2007 - 12:24 am
I will be finishing a Masters in Chemical Engineering with an emphasis in process control in a few months and am trying to understand my future employment options...
New Replies:
By Older technician on 13 July, 2008 - 12:13 pm -
I've been around manufacturing and power plants almost all of my working life and I agree with...
from the Automation List department...
GE frame 9 Gas Turbine ' failure to synchronize'
Topic: Continuous process industries, DCS questions.
Originally posted by anonymous on 7 January, 2007 - 11:58 am
GE Frame 9 gas turbine with mark iv control system fails to synchronize...
New Replies:
By CSA on 13 July, 2008 - 12:12 pm -
I have been accused of being a swashbuckler, in my younger days. But, that was a long, long,...
from the R&D department...
Modbus Communication and Time Stamp
Topic: Communications systems and equipment.
Originally posted by Ravi on 13 June, 2008 - 6:59 pm
Getting the status information of a device(example a relay) along with the time stamp on modbus protocol.
New Replies:
By Booatoa on 13 July, 2008 - 12:09 pm -
Yes we cannot transmit time stamp packets. In my opinion you just synchronise time between PLC and...
from the Instrumentation & Control department...
Dilemma with Honeywell's TPS/TDC3000
Topic: Application Questions and Problems
Originally posted by Rahul P Sharma on 26 July, 2007 - 10:43 pm
Dilemma with Honeywell's TPS/TDC3000
New Replies:
By Joe North on 13 July, 2008 - 12:08 pm -
TPS and GUS are still fully supported products. GUS is available for use on Windows XP and on the...
from the Automation List department...
Historian
Topic: Human-Machine Interface and SCADA.
Originally posted by CJ on 3 July, 2008 - 10:50 pm
I want to find out if it will be possible to run a program like Matrikon if we are not using a dedicated Historian.
New Replies:
By burnikell on 13 July, 2008 - 12:06 pm -
Hi there CJ, First place to start is with your architecture. Iconics is a vendor that uses OPC...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!