Wednesday, July 30, 2008from the Automation List department...
Re: MarkV Governor Control ModesWhat MarkV mode is used to control 10MW steam turbine generator in droop?
from the Automation List department...
Re: How is GE giving Frame numbers?How is GE giving different Frame numbers like Frame 5, Frame 6, Frame 7 and so on?
from the Engineering department...
Bus tie breakers not closing before synchronizing power stationsBus tie breakers not closing without synchronizing the two power stations.
from the Maintenance department...
Breaker failure arc flash disasterIf you think the new arc flash protection requirements are too draconian, think again.
from the Automation department...
S7 Project ComparisonsI had a problem recently comparing an S7 offline vs. online project using the Compare Blocks interface. I need suggestions on how to pick up these differences without having to go online to each block.
from the Automation List department...
Re: 24 VDCAC vs DC 24V Relays.
from the Modbus department...
Modbus Register ScalingI want to bring data from controller through a Modbus link. The flow is 0-101000 SCFM and the register is scaled for 0-102.4%.
from the Automation List department...
Re: 24 VDCAC vs DC 24V Relays.
from the Help with encoder and PLC program bascis department...
Is anyone experienced with Omron PLC?I saw a previous post of somebody wanting help with using an encoder with a PLC
from the Automation List department...
Determining the settling properties of slurriesDevelopment settling test for opaque solution.
from the Automation List department...
Re: Unequal load sharing of generatorsI have a question about unequal load sharing of generators.
from the Mark IV department...
Mark IV indication errors on startupIndications jump or drop out at 3600 RPM for 15 seconds and than trip on IGV trouble.
from the Urgent issue! department...
Re: CNC Bosch Alpha2 questionI have a Bosch alpha 2, and I can't change any parameters...
from the Automation List department...
How is GE giving Frame numbers?How is GE giving different Frame numbers like Frame 5, Frame 6, Frame 7 and so on?
from the Control and Instrumentation department...
Boiler Three Element Drum Level ControllerWhat is the best equation for the cascade control we should maintain for three element in boiler drum level control?
from the Automation List department...
Using a CNC controller to control a 6 DOF industrial robotOur goal is replacing the controller of some old 6 DOF robots
from the Analyser department...
Boiler Flue Gas AnalysisWe have a gas firing boiler. We have measured %O2 in flue gas 3.5%. We have no online analyser. How we measure to maintain it at 1% level, total NG will be saved?
from the C & I department...
HP Top Bottom Casing Temp Protection for Steam TurbineWhy do we need to provide HP TOP BOTTOM Casing Temp Protection for Steam turbine?
from the Automation List department...
Analog signal acquisition for connecting to PCData acquisition of analog I/Ps & display on PC with trending & history facility
from the Flow Measurment department...
Orifice plates and air flowCan we use the same orifice plate with increased air flow?
from the Automation department...
Re: I have a problem for long instrument cablesthe problem is the distance between the transmitter and the RTU, which is 3000 m....
from the Project department...
Electrical TransformerStep Up or Step Down transformer
from the Automation List department...
Re: Ethernet "hard" switchI'm looking for industrial hardware solution to commute a ethernet slave station from a PLC to another.
from the Automation List department...
Controller, microcontrollerController, microcontroller - difference
from the Automation List department...
Re: Embedded systems courses in Mumbai, Indiacan anybody give me info about the best institute which provides embedded software training in mumbai (its contact details, if possible)?
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.
Users of this site are benefiting from open source technologies, including PHP, PostgreSQL and Apache. Be happy.
Our Advertisers
Help keep our servers running...
Patronize our advertisers!
Patronize our advertisers!