Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
Hire the morally handicapped.
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Saturday, August 2, 2008
from the Automation List department...
Water tank level
Topic: Sensor technologies.
Originally posted by Martin on 23 July, 2008 - 9:50 pm
I need a solution to continuously measure the water level in a tank.
New Replies:
By wboyes on 2 August, 2008 - 8:01 pm -
Roy, all of the options you mention will work just fine, but they range from spendy to spendier to...
By wboyes on 2 August, 2008 - 4:56 pm -
Cheapest way to do it with a 4-20 mADC output I can think of is a (cigar shaped) submersible...
By Roy Matson on 2 August, 2008 - 12:41 pm -
Do you really mean 18 inches?, this is very short for a DP cell. A few more Options Ultrasonic ...
from the Technology department...
Comparision Between Iconics and ABB
Topic: Software, including programming, OS issues, etc.
Originally posted by SIS on 2 August, 2008 - 12:41 pm
Comparision Bewteen Iconics and ABB
New Replies:
By wboyes on 2 August, 2008 - 7:58 pm -
Ok. Let us not compare apples to oranges. Iconics is a software company. They make HMI and...
By Curt Wuollet on 2 August, 2008 - 5:15 pm -
White papers are seldom, if ever, unbiased. Regards cww...
from the Automation List department...
Inheritance (object-oriented) in PLC programming?
Topic: Software, including programming, OS issues, etc.
Originally posted by Zen Master Soso on 1 August, 2008 - 11:22 pm
Does any PLC programming software implement the object-oriented-programming concept of "inheritance"?
New Replies:
By David on 2 August, 2008 - 7:55 pm -
Check out Codesys, an object oriented development platform that is device independent (specific...
By DAVE FERGUSON on 2 August, 2008 - 5:00 pm -
RSLogix 5k does this today in version 16 and above with something called an AOI (Add On...
from the Automation department...
ML1100 to Honeywell ModBus Comms Prob
Topic: PLCs and related questions.
Originally posted by joe on 2 August, 2008 - 1:22 pm
I can not get my ML1100 to communicate with my honeywell 8010m comms module.
New Replies:
By Issac on 2 August, 2008 - 7:52 pm -
What is a 'Honeywell 8010m comms module'? Can you provide a link to the communications...
from the Maintenance department...
Air compressor motor problem
Topic: Engineering and workplace issues.
Originally posted by Jorge on 4 June, 2008 - 12:42 am
150HP Quincy air compressor motor pulling 206A,
motor is running 3@ 260VA/170A
New Replies:
By Phil Corso on 2 August, 2008 - 7:37 pm -
The motor is not OK! Tt's overloaded by about 22%. Scott's comment to check the input voltage is...
By Curt Wuollet on 2 August, 2008 - 5:14 pm -
Also, unless it is a straight across the line arrangement, (and sometimes even if it's an across...
By Scott Biscobing on 2 August, 2008 - 12:40 pm -
Have you checked input voltage? A defect in a step up/down transformer or a load elsewhere in your...
from the Automation List department...
selecting a suitable dc a PM dc motor for a flywheel
Topic: Motion control, servos, steppers, etc.
Originally posted by Interesting on 2 August, 2008 - 1:22 pm
I need to choose a suitable PMdc motor for a flywheel (Diametre = 0.38m, m =10kg).
New Replies:
By Curt Wuollet on 2 August, 2008 - 5:18 pm -
Sure it will spin the flywheel, with proper bearings. What you haven't mentioned is what power you...
from the Automation List department...
SPPA-T2000 APF vs AP
Topic: Engineering and workplace issues.
Posted by Mik on 2 August, 2008 - 5:16 pm
Deciding wheteher to use SPPA-T2000 fail safe processors or not.
from the Automation List department...
Reading data of an energymeter vm22-din
Topic: Computers in manufacturing; also hardware discussion.
Posted by Anders on 2 August, 2008 - 5:13 pm
Trying to read data of an energymeter VM22-DIN from CARLO GAVAZZI using rs485 and AK-Nords Din-Rail-Lan device server. Trying to use modpoll to read data.
from the Automation List department...
Automation replacing people
Topic: Engineering and workplace issues.
Originally posted by Marc Sinclair on 28 July, 2000 - 9:00 am
How do you rationalise situations in which machines replace workers?
New Replies:
By TonopahJoe on 2 August, 2008 - 5:12 pm -
As a former employee of a semi-conductor company, I once automated an RO system that had been run...
from the Instrument department...
Flow and MOV questions
Topic: Application Questions and Problems
Originally posted by pc on 1 August, 2008 - 11:23 pm
Flow and MOV
New Replies:
By John Catch on 2 August, 2008 - 5:10 pm -
There are a number of factors when it comes to straight run requirements. The ASME has some...
By Roy Matson on 2 August, 2008 - 12:39 pm -
1/ 20 & 10 is the minimum I would aim for but I don't claim to be a specialist. i.e. for...
from the Automation List department...
analoge to fiber optic converter
Topic: Communications systems and equipment.
Originally posted by Radwan on 8 March, 2008 - 10:55 am
analoge to fiber optic converter
New Replies:
By Roy Matson on 2 August, 2008 - 5:02 pm -
Ignacio - Excelent solution, have you experience with these? I like the multiplexer on page 22 of...
from the Automation List department...
boiler drum level calibration with DPT
Topic: Continuous process industries, DCS questions.
Originally posted by Minesh Desai on 2 August, 2008 - 1:21 pm
How to calibrate DPT for boiler drum level control? How to decide range of DPT?
New Replies:
By CTTech on 2 August, 2008 - 5:01 pm -
The drum level transmitter generally uses hydrostatic head method of measurement. The span is...
Topic: Engineering and workplace issues.
Posted by speedtronic on 2 August, 2008 - 4:51 pm
Is there any limit for Na + K in Furnace Oil/HSD used in GE Frame9 Gas Turbines? Can't find any in their operating manuals.
Topic: Motion control, servos, steppers, etc.
Posted by paru on 2 August, 2008 - 1:23 pm
in my transformer i need to check the protection.
from the System Integrator department...
Johnson Controls DSC 8500
Topic: Human-Machine Interface and SCADA.
Posted by Tim on 2 August, 2008 - 1:21 pm
anyone have any experience communicating ifix 4.0 with the older Johnson Controls DSC 8500 DDC's?
from the Automation List department...
GE Source book required
Topic: Application Questions and Problems
Originally posted by MAKH on 1 August, 2008 - 11:33 pm
GE Source book FJ3B for power augmentation
New Replies:
By CSA on 2 August, 2008 - 1:20 pm -
GE Sourcebook articles would be proprietary information, not for public dissemination. It might be...
from the Automation List department...
Different PLC Manufacturer's Market Share
Topic: PLCs and related questions.
Originally posted by Hamid on 4 October, 2007 - 8:34 pm
Does Anybody Know The Different PLC Manufacturer's Market Share?
New Replies:
By Saji.T.R on 2 August, 2008 - 12:46 pm -
Dear Gurmeet I acannot exactly remember the source, I hope it was from web or some presentations,...
from the I&C department...
SPPA-T1000 compared with SPPA-T3000
Topic: Engineering and workplace issues.
Originally posted by Pankaj Dave on 2 April, 2008 - 12:20 am
Can anyone tell if SPPA-T1000 system from Siemens has reference outside of India? We want to have real feedback for this system and comparison with SPPA-T3000.
New Replies:
By Robin Ray on 2 August, 2008 - 12:45 pm -
Deejay, (1)We are getting supply of big steam turbines from Siemens together with SPPA-T3000. We...
from the Instrumentation & Control department...
Temp Control Mode: Frame V Turbines
Topic: Application Questions and Problems
Originally posted by Rahul P Sharma on 1 August, 2008 - 11:32 pm
A question on temp control mode.
New Replies:
By CTTech on 2 August, 2008 - 12:44 pm -
You should have a warm up period where exhaust temp is regulated to 550 F. When the warm up...
from the Automation List department...
Intergraph Intools Problem
Topic: Information resources, documentation.
Posted by Apple on 2 August, 2008 - 12:43 pm
I changed the data using spec binder module. when I updated the revision the change did not show but it shows on the summary report.
from the Electrical department...
PLCC
Topic: Application Questions and Problems
Originally posted by anonymous on 30 July, 2008 - 11:18 pm
Presentation of PLCC
New Replies:
By P. Wakhale on 2 August, 2008 - 12:38 pm -
Dear Anonymous, For practical example & details, I would suggest you to visit a nearby 132 /...
from the Maintenance department...
Analog vs. digital control. Which is best?
Topic: Continuous process industries, DCS questions.
Posted by TurboYankee on 2 August, 2008 - 12:37 pm
We're adding critical controls at a distance of 3,200 ft. & are debating digital vs. analog control.
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!