Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
There are three kinds of lies: Lies, Damn Lies, and Statistics.
-- Disraeli
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Sunday, August 10, 2008
from the Automation List department...
Foxboro DCS and HMI
Topic: Human-Machine Interface and SCADA.
Originally posted by Afshin on 25 July, 2007 - 10:53 pm
I have a DCS system of Foxboro that its HMI is very old. I want to upgrade this HMI without change...
New Replies:
By Chris Jennings on 10 August, 2008 - 8:27 pm -
I think you forgot to add IMHO. Chris Jennings...
from the Swimming in Mud department...
Mud Level inside a Thickener
Topic: Application Questions and Problems
Originally posted by Thys on 9 August, 2008 - 1:29 pm
looking for an Instrument of some sort that can show me the Mud Level inside a Thickener
New Replies:
By wboyes on 10 August, 2008 - 8:26 pm -
I've used the ultrasonic thingys, from several different manufacturers, and they seem to work okay...
By Roy Matson on 10 August, 2008 - 3:42 pm -
I worked in mining for a lot of years, most of the thickeners had a float device. A SS ball about...
Topic: Engineering and workplace issues.
Originally posted by p on 10 August, 2008 - 3:47 pm
link for the free Down loadable PDF book for Basics of Control and instruments?
New Replies:
By wboyes on 10 August, 2008 - 8:25 pm -
Why does it have to be free? Some of us make our living writing these books, and we have to eat and...
from the Automation List department...
To implement Modbus Poll
Topic: Communications systems and equipment.
Originally posted by sonainv on 10 August, 2008 - 3:52 pm
To query the status of the Registers of an energy meter using MODBUS RTU protocol
New Replies:
By Colman on 10 August, 2008 - 5:31 pm -
Check your slave address.Also check the energy meter with the RS232-RS232 communication then the...
By Mark on 10 August, 2008 - 4:48 pm -
Hello, Download the serial slave simulator from http://www.peakhmi.com and verify your code. ...
By autcon20 on 10 August, 2008 - 4:48 pm -
Try to get a ModBus Slave simulator, and test your code. Also you could get a ModBus Master...
from the Automation List department...
High vibration at reduced load
Topic: Engineering and workplace issues.
Originally posted by kumarash on 10 August, 2008 - 3:47 pm
When we reduce load on GE Frame9 Gas turbine vibration of bearings #2 and 3 increases
New Replies:
By CSA on 10 August, 2008 - 4:47 pm -
When did this begin occurring; after a maintenance outage? How long has this been occurring? ...
from the Automation List department...
Modbus Communication between Twido & Altivar 2
Topic: Communications systems and equipment.
Posted by Naveed ahmed on 10 August, 2008 - 3:51 pm
Modbus Communication between Twido and Altivar 21
from the Automation List department...
Redundant AC800M
Topic: Engineering and workplace issues.
Originally posted by Mik on 7 August, 2008 - 12:16 am
Redundancy feature of AC800M controller from ABB
New Replies:
By Mik on 10 August, 2008 - 3:51 pm -
Hello, I'm very interested in this. Can you provide more informations, or direct me where I can...
from the IC department...
Mark-V &l IDOS
Topic: Communications systems and equipment.
Posted by Ifo on 10 August, 2008 - 3:50 pm
Mark-V <I>(IDOS) screen freezes every three/four hours.
from the Maintenance department...
Direct Connection from a NOM to Momentum PLC
Topic: PLCs and related questions.
Posted by Colman on 10 August, 2008 - 3:49 pm
Is it possible to connect a Modbus Trunk cable from a Quantum PLC to a Momentum PLC in the field using a NOM?
from the Automation List department...
What makes a generator increase load
Topic: Engineering and workplace issues.
Posted by kumarash on 10 August, 2008 - 3:49 pm
What makes a generator coupled to a gas turbine increase load when load raise command is issued to Mark V
Topic: Motion control, servos, steppers, etc.
Originally posted by Najafabadi on 30 July, 2008 - 11:45 pm
Our goal is replacing the controller of some old 6 DOF robots
New Replies:
By Najafabadi on 10 August, 2008 - 3:48 pm -
Thank you Gavenb. Any body has any other recommendations?...
from the Ventilation department...
Thermocouple and VFD fan control
Topic: Continuous process industries, DCS questions.
Originally posted by cammrit on 7 August, 2008 - 12:54 am
Need help on thermocouple wiring.
New Replies:
By Curt Wuollet on 10 August, 2008 - 3:46 pm -
Hi Carl Just as a note, rtds and thermistors change resistance with temperature as their...
By Roy Matson on 10 August, 2008 - 3:28 pm -
Carl, No, thermocouples don't change resistance they are low resistance devices but they produce a...
By Dick Caro on 10 August, 2008 - 3:26 pm -
Carl, Maybe your circuit doesn't work well because you just do not understand the basics of...
from the Automation List department...
How can you mask an output card in Step 7?
Topic: PLCs and related questions.
Originally posted by o4a0e1 on 8 August, 2008 - 7:45 pm
What I'm trying to do is use 3 outputs on a card as a BCD to another device. I'm getting some obvious issues and would like to find out the best way to overcome them.
New Replies:
By David Adams on 10 August, 2008 - 3:45 pm -
First, transfer the decimal value to a storage byte. Next use another storage byte to hold the...
from the Automation List department...
Power Line Networking
Topic: Local and wide area networking in factory automation.
Originally posted by Jeremy Pollard on 8 August, 2008 - 1:42 am
I have an application that has 4 in/2 out and has 65 locations along a linear path...
New Replies:
By Paul Wacker on 10 August, 2008 - 3:30 pm -
Jeremy - The most commercially viable solution for this is Homplug, which carries Ethernet over...
By Roy Matson on 10 August, 2008 - 3:29 pm -
Jeremy, Perhaps this might be of interest http://www.powercorp.com.au/pdf/bpl.pdf I'm sure there...
from the electrical eng. department...
web site with free electrical book
Topic: Information resources, documentation.
Originally posted by hamada farag on 5 January, 2005 - 3:42 pm
electrical book in pdf on net
New Replies:
By NLN on 10 August, 2008 - 3:24 pm -
There are many hand books available in pdf format for free download in Department of energy web...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!