Saturday, August 30, 2008Bacnet software server or hardware protocol translator
New Replies:
By Mayoor on 30 August, 2008 - 6:29 pm -
By Mayoor on 30 August, 2008 - 6:29 pm -
Sunlux Technologies has a solution which provides a protocol converter for Modbus(TCP/IP or Serial)...
Where can I get MarkIV maintenance manual?
How do I run one application of RSView32 with two monitors?
Communicating between a S7-200, a Simatic Panel and a PC
New Replies:
By David Adams on 30 August, 2008 - 6:23 pm -
By David Adams on 30 August, 2008 - 6:23 pm -
Jespejo,
You have a few options. Feel free to contact me at
dadams @ controlproductsinc . net...
WinCC doesn't seem to "know" the 3500/92...
how to wire smoke detector
When we started the compressor, GTG output frequency dropped down and it was automatically changed to Droop mode...
New Replies:
By jojo on 30 August, 2008 - 6:17 pm -
By jojo on 30 August, 2008 - 6:17 pm -
A couple of things could have caused your frequency to fall:
1. Do you have a temperature...
what is relation between primary current and reactor.
Can anyone please suggest the type of flow meter...
New Replies:
By JMW on 30 August, 2008 - 6:10 pm -
By JMW on 30 August, 2008 - 6:10 pm -
I'd suggest talking to Actaris (Formerly a Schlumberger company) about their MZ or fluxi gas...
6900/440 Volt, 1600 KVA transformer testing
How does GPS work, and what is it's use in power plants?
New Replies:
By Roy Matson on 30 August, 2008 - 5:56 pm -
By Roy Matson on 30 August, 2008 - 5:56 pm -
Perhaps they use it to determine which phase is A phase? Some of you might get that!
Roy...
By Eric Ratliff on 30 August, 2008 - 5:37 pm - I'm almost sure it's about getting good time synchronization. One of my customers in the power...
Shield of a Transmitter cable.
New Replies:
By Roy Matson on 30 August, 2008 - 5:55 pm -
By Roy Matson on 30 August, 2008 - 5:55 pm -
To prevent ground loops which in turn cause noise on the signal. It only takes small changes in...
Modbus TCP/IP data concentrator. Need a device that can receive data from mutliple Modbus TCP/IP slaves, stores them and can act as a MModbus TCP/IP slave for the DCS controller.
New Replies:
By Michael Griffin on 30 August, 2008 - 5:54 pm -
By Michael Griffin on 30 August, 2008 - 5:54 pm -
I think what you mean is you want an "out of the box" solution. You could run MBServer on...
PLC didnt answer
New Replies:
By Eric Ratliff on 30 August, 2008 - 5:52 pm -
By Eric Ratliff on 30 August, 2008 - 5:52 pm -
I have never heard of putting pauses between characters of a Modbus RTU command or response. I...
What is the best simulation software?
New Replies:
By Andrew on 30 August, 2008 - 5:36 pm -
By Andrew on 30 August, 2008 - 5:36 pm -
Hi,
Thanks’ for all your help,
I am looking at a number of products and have not yet decided...
Large variations are seen in the Level Transmitter installed on Ammonia service.
New Replies:
By Bruce Thompson on 30 August, 2008 - 5:34 pm -
By Bruce Thompson on 30 August, 2008 - 5:34 pm -
Have you checked for blockage in the pressure lines?
Since the transmitter is slow in responding...
2 Panelviews for one CPU
What makes Moog servos having different types P1, P2, P4 and P7 different from each other?
New Replies:
By robin Enderby on 30 August, 2008 - 5:33 pm -
By robin Enderby on 30 August, 2008 - 5:33 pm -
The numbers P1 etc are not Moog part numbers.
Typically you will be using The 77K-XXX series.
...
If we increase time delay for shutdown to 30 secs, fuel changeover valve would change position & there would be no shut down BUT m/c would run on furnace oil without additive dosing for approx. 20 seconds...
UnityPro XL is running slow, V3.1-SP1.
New Replies:
By edprivate on 30 August, 2008 - 5:29 pm -
By edprivate on 30 August, 2008 - 5:29 pm -
Is anyone else even using this software?
I can't be the only one. Can I?
By the way I am...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.