Saturday, August 30, 2008
from the Automation List department...
Bacnet into an HMI Client
Topic: Communications systems and equipment.
Originally posted by Jim on 23 January, 2001 - 11:35 am
Bacnet software server or hardware protocol translator
New Replies:
By Mayoor on 30 August, 2008 - 6:29 pm -
Sunlux Technologies has a solution which provides a protocol converter for Modbus(TCP/IP or Serial)...
from the Automation List department...
Mark IV maintenance manual
Topic: Information resources, documentation.
Posted by Sachin on 30 August, 2008 - 6:28 pm
Where can I get MarkIV maintenance manual?
from the ROCKWELL department...
RSView32 Dual Monitors
Topic: Human-Machine Interface and SCADA.
Posted by MalibuSteve on 30 August, 2008 - 6:24 pm
How do I run one application of RSView32 with two monitors?
from the communications department...
Communicate between S7-200, a Simatic Panel and a PC?
Topic: PLCs and related questions.
Originally posted by Jespejo on 27 August, 2008 - 10:22 pm
Communicating between a S7-200, a Simatic Panel and a PC
New Replies:
By David Adams on 30 August, 2008 - 6:23 pm -
Jespejo, You have a few options. Feel free to contact me at dadams @ controlproductsinc . net...
from the Automation List department...
bently 3500/92 communication
Topic: Communications systems and equipment.
Posted by cheraghi on 30 August, 2008 - 6:20 pm
WinCC doesn't seem to "know" the 3500/92...
from the fire & gas department...
smoke detector and PLC
Topic: Application Questions and Problems
Posted by PC on 30 August, 2008 - 6:18 pm
how to wire smoke detector
from the Instrumentation department...
Auto change over from ISCHO to Droop mode
Topic: Engineering and workplace issues.
Originally posted by Rajkumar on 29 August, 2008 - 4:57 pm
When we started the compressor, GTG output frequency dropped down and it was automatically changed to Droop mode...
New Replies:
By jojo on 30 August, 2008 - 6:17 pm -
A couple of things could have caused your frequency to fall: 1. Do you have a temperature...
from the maintenance department...
transformer primary current with reactor
Topic: Engineering and workplace issues.
Posted by pk on 30 August, 2008 - 6:11 pm
what is relation between primary current and reactor.
from the Instrumentation department...
Fuel gas metering
Topic: Continuous process industries, DCS questions.
Originally posted by Zahid on 26 August, 2008 - 9:53 am
Can anyone please suggest the type of flow meter...
New Replies:
By JMW on 30 August, 2008 - 6:10 pm -
I'd suggest talking to Actaris (Formerly a Schlumberger company) about their MZ or fluxi gas...
from the Electrical department...
Bus Bar
Topic: Information resources, documentation.
Posted by ASMI on 30 August, 2008 - 6:09 pm
Bus bar calculation
from the Electrical department...
Power transformer Test
Topic: Engineering and workplace issues.
Posted by Iqbal on 30 August, 2008 - 5:56 pm
6900/440 Volt, 1600 KVA transformer testing
from the Instrument and Control department...
GPS System
Topic: Communications systems and equipment.
Originally posted by RAJ BAHADUR on 26 August, 2008 - 1:25 am
How does GPS work, and what is it's use in power plants?
New Replies:
By Roy Matson on 30 August, 2008 - 5:56 pm -
Perhaps they use it to determine which phase is A phase? Some of you might get that! Roy...
By Eric Ratliff on 30 August, 2008 - 5:37 pm -
I'm almost sure it's about getting good time synchronization. One of my customers in the power...
from the Instrumentation department...
Transmitter cable shielding
Topic: Continuous process industries, DCS questions.
Originally posted by Anonymous on 20 July, 2008 - 1:02 pm
Shield of a Transmitter cable.
New Replies:
By Roy Matson on 30 August, 2008 - 5:55 pm -
To prevent ground loops which in turn cause noise on the signal. It only takes small changes in...
from the Modbus Interface department...
ModbusTCP/IP data concentrator
Topic: Engineering and workplace issues.
Originally posted by Syed Hussain on 27 August, 2008 - 9:58 pm
Modbus TCP/IP data concentrator. Need a device that can receive data from mutliple Modbus TCP/IP slaves, stores them and can act as a MModbus TCP/IP slave for the DCS controller.
New Replies:
By Michael Griffin on 30 August, 2008 - 5:54 pm -
I think what you mean is you want an "out of the box" solution. You could run MBServer on...
from the Modbus application software department...
Modbus query problem
Topic: Communications systems and equipment.
Originally posted by David Cemin on 24 August, 2008 - 8:54 pm
PLC didnt answer
New Replies:
By Eric Ratliff on 30 August, 2008 - 5:52 pm -
I have never heard of putting pauses between characters of a Modbus RTU command or response. I...
from the Operations department...
Simulation Software
Topic: Software, including programming, OS issues, etc.
Originally posted by Andrew on 7 August, 2008 - 12:47 am
What is the best simulation software?
New Replies:
By Andrew on 30 August, 2008 - 5:36 pm -
Hi, Thanks’ for all your help, I am looking at a number of products and have not yet decided...
from the Instrument department...
Level Transmitter False Reading
Topic: Engineering and workplace issues.
Originally posted by Bilal on 28 August, 2008 - 9:48 am
Large variations are seen in the Level Transmitter installed on Ammonia service.
New Replies:
By Bruce Thompson on 30 August, 2008 - 5:34 pm -
Have you checked for blockage in the pressure lines? Since the transmitter is slow in responding...
from the Automation List department...
Panelview and 503
Topic: Communications systems and equipment.
Originally posted by sosa on 27 August, 2008 - 10:24 pm
2 Panelviews for one CPU
New Replies:
By Sosa on 30 August, 2008 - 5:34 pm -
Tanks a lot Trevor. I will try Regards, Sosa...
from the Inst. Maint. Department department...
Servo Valves of Gas Turbine
Topic: Engineering and workplace issues.
Originally posted by Mehul Jesalpura on 3 July, 2008 - 1:10 am
What makes Moog servos having different types P1, P2, P4 and P7 different from each other?
New Replies:
By robin Enderby on 30 August, 2008 - 5:33 pm -
The numbers P1 etc are not Moog part numbers. Typically you will be using The 77K-XXX series. ...
Topic: Engineering and workplace issues.
Posted by speedtronic on 30 August, 2008 - 5:32 pm
If we increase time delay for shutdown to 30 secs, fuel changeover valve would change position & there would be no shut down BUT m/c would run on furnace oil without additive dosing for approx. 20 seconds...
from the Software Speed Issue department...
UnityPro XL Software Speed Issues
Topic: Software, including programming, OS issues, etc.
Originally posted by edprivate on 27 August, 2008 - 10:19 pm
UnityPro XL is running slow, V3.1-SP1.
New Replies:
By edprivate on 30 August, 2008 - 5:29 pm -
Is anyone else even using this software? I can't be the only one. Can I? By the way I am...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.