Tuesday, September 9, 2008
from the instrumentation department...
PID tuning help
Topic: Motion control, servos, steppers, etc.
Originally posted by pk on 8 September, 2008 - 4:57 pm
Oscillations in control system.
New Replies:
By Morpheus on 9 September, 2008 - 1:16 am -
Hi there, Have you tried using the offline tuning method? If possible, try to do a step test and...
By George Younkin on 9 September, 2008 - 12:41 am -
pk, If it will be of any help, I can email documents on the basics of PID to you. Contact me if...
from the Instrument department...
CS3000 Yokogawa DCS
Topic: Engineering and workplace issues.
Originally posted by Imran on 8 September, 2008 - 4:44 pm
Isolation of operating station by changing the position of terminating resistor on CS3000 DCS failed.
New Replies:
By Shahid Waqas on 9 September, 2008 - 1:14 am -
It would be a good idea to contact your local Yokogawa service centre. They would help you in...
By wboyes on 9 September, 2008 - 12:52 am -
For your sake, and the sake of your co-workers, PLEASE call Yokogawa for assistance. Replacing...
from the Automation List department...
Mark 5. Analog I/O card problem
Topic: Continuous process industries, DCS questions.
Originally posted by rabia on 28 August, 2008 - 9:47 am
Analog I/O card replaced in <T> core, but processor booted up till A6 (should have gone till A7 for okay status) and indicated "I/O card missing alarm"
New Replies:
By rabia on 9 September, 2008 - 1:06 am -
Anyone has any info to share??...
from the Old Days department...
Vintage Field Instrumentation
Topic: Information resources, documentation.
Originally posted by stemp on 6 September, 2008 - 2:02 pm
need information for absolete field Instrument
from the Automation List department...
Inheritance (object-oriented) in PLC programming?
Topic: Software, including programming, OS issues, etc.
Originally posted by Zen Master Soso on 1 August, 2008 - 11:22 pm
Does any PLC programming software implement the object-oriented-programming concept of "inheritance"?
New Replies:
By James Ingraham on 9 September, 2008 - 1:04 am -
"...if you insist to use the OOP-style order, I have no objections." Well, it's not so...
from the Control Engineer department...
Mark 6 - VPRO diagnostic alarm
Topic: Application Questions and Problems
Originally posted by AmAm on 17 August, 2008 - 12:46 pm
we experience the following alarm diagostic alarm on VPRO Z: The solenoid voltage 06 mismatch request state.
New Replies:
By CSA on 9 September, 2008 - 1:00 am -
There's a couple more things I want to bring up here. You mentioned disabling monitoring of contact...
from the Automation List department...
Annubar calculation
Topic: Application Questions and Problems
Originally posted by bekazemian on 8 September, 2008 - 5:22 pm
Our annubar was broken.
New Replies:
By wboyes on 9 September, 2008 - 12:58 am -
You have an inserted hollow stick, with holes in it, in a 52" diameter pipe, flowing 2000 T/h....
from the gas turbines department...
MarkV controls
Topic: Application Questions and Problems
Originally posted by ankarao on 8 September, 2008 - 4:52 pm
MarkV controls problem
New Replies:
By CSA on 9 September, 2008 - 12:52 am -
If you look in the Mark V Maintenance Manual, GEH-5980, you will see that all of the cards which...
from the Instrumentation department...
Auto change over from ISCHO to Droop mode
Topic: Engineering and workplace issues.
Originally posted by Rajkumar on 29 August, 2008 - 4:57 pm
When we started the compressor, GTG output frequency dropped down and it was automatically changed to Droop mode...
New Replies:
By CSA on 9 September, 2008 - 12:45 am -
You should obtain the services of someone who's knowledgeable in Mark IV Speedtronic turbine...
from the Instrument and Control systems department...
New "DCS" control system selection
Topic: Continuous process industries, DCS questions.
Originally posted by George Whaley on 3 September, 2008 - 12:24 am
Requesting member feedback for the replacement selection of an existing petrochemical control system "DCS".
New Replies:
By wboyes on 9 September, 2008 - 12:45 am -
MTL recently sold the MOST system to GE Fanuc, who are just pleased as punch with their new...
By dsiler on 9 September, 2008 - 12:16 am -
I am not an Emerson Distributor, just an integrator that's been working with Delta V for 11 years...
from the Automation List department...
Restart GE Mark V HMI online?
Topic: Human-Machine Interface and SCADA.
Originally posted by dinster on 12 August, 2008 - 12:57 am
On why restarting Mark V HMI is not advisable.
New Replies:
By CSA on 9 September, 2008 - 12:40 am -
dinster, About the ONLY reason one would not want to re-boot a GE Mark V operator interface is...
from the Mark IV department...
Mark IV indication errors on startup
Topic: Continuous process industries, DCS questions.
Originally posted by John Tennyson on 30 July, 2008 - 11:52 pm
Indications jump or drop out at 3600 RPM for 15 seconds and than trip on IGV trouble.
New Replies:
By John Tennyson on 9 September, 2008 - 12:29 am -
To start with the battery. The voltage was suspect. We put in a new battery. The 125Vdc bus was...
from the Automation List department...
MKV Enumerated state command
Topic: Software, including programming, OS issues, etc.
Originally posted by martinc on 26 August, 2008 - 4:31 pm
Creating an enmurated state and adding to a user defined display
New Replies:
By Simon on 9 September, 2008 - 12:29 am -

Hi CSA,

I am a colleague of Martin's and have been working with him on this...

from the Algorithm department...
Back Propagation ANN
Topic: Engineering and workplace issues.
Posted by Hemlal on 9 September, 2008 - 12:23 am
How to train ANN using Matlab for given input and Target?
from the Automation List department...
Measuring static pressure in GT exhaust system
Topic: Information resources, documentation.
Posted by Mike H on 9 September, 2008 - 12:22 am
Measuring static pressure losses in exhaust duct on GE LM6000 gas turbine.
Topic: Motion control, servos, steppers, etc.
Originally posted by Anonymous on 5 August, 2002 - 12:28 pm
I design a interface circuit of sin/cos encoder,
but i don't know the amplitude of its output. Do different companies produce this kind of encoder with the same output voltage amplitude?
New Replies:
By Jim Miller on 9 September, 2008 - 12:17 am -
Chinmay, I am not sure what you mean exactly. It sounds as though you are looking for a...
from the Operation department...
Isochronous Control
Topic: Continuous process industries, DCS questions.
Originally posted by ST on 8 August, 2008 - 7:53 pm
Question on Isochronous Mode of Control
New Replies:
By DMello on 9 September, 2008 - 12:14 am -
For MKV - On main display there is no provision to change TNRI_CMD. You have to go to...
from the DLN Tuning department...
DLN Tuning gas turbines
Topic: Engineering and workplace issues.
Posted by Brian on 9 September, 2008 - 12:05 am
Can anyone explain to me the meaning of "DLN system tuning"?
from the Automation List department...
SCADA Evaluation
Topic: Software, including programming, OS issues, etc.
Posted by Ketan on 9 September, 2008 - 12:04 am
What are the parameters to be considered for SCADA system evaluation?
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.