MKVI Generator Synchronization
Topic: Engineering and workplace issues.
Originally posted by MIKEVI on 12 September, 2008 - 1:57 am
MKVI Generator Synchronization Trouble
New Replies:
By MIKEVI on 13 September, 2008 - 2:24 pm -
Thank you CSA for your time and thoughts. To answer some of your questions and comments: Yes,...
By CSA on 13 September, 2008 - 1:33 am -
MIKEVI, Through all the troubleshooting you did this past weekend, you didn't mention any...
from the automotive department...
fast range finder
Topic: Sensor technologies.
Posted by dag on 13 September, 2008 - 2:22 pm
Fast range finder sensor for a dusty environment.
from the Automation List department...
Frame-6 MKV GT constants
Topic: Continuous process industries, DCS questions.
Originally posted by Demello on 11 September, 2008 - 1:31 am
Frame-6 MKV Gas Turbine Constants
New Replies:
By DMELLO on 13 September, 2008 - 2:22 pm -
Sure sir agree with you, But as due to plant requirement unable to stop the GT and only...
from the Automation List department...
Coriolis PTFE coated
Topic: Sensor technologies.
Originally posted by Enric_Tgn on 12 September, 2008 - 12:36 am
Coriolis with acid resistant coating
New Replies:
By Roy Matson on 13 September, 2008 - 2:20 pm -
I couldn't access Ulf's link but I found this one We buy lots of MM meters for acid service but i...
By Ulf on 13 September, 2008 - 12:39 am -
Micro Motion got Coriolis massflow sensor coated with Tefzel, which is similar to PTFE/PFA. Here...
Topic: Engineering and workplace issues.
Originally posted by sunny on 13 September, 2008 - 12:28 am
How do positive displacement level detectors work?
New Replies:
By Roy Matson on 13 September, 2008 - 2:20 pm -
I haven't heard the term applied to a level detector. It's usually applied to a Pump e.g. Gear or...
from the R&D department...
Fire Alarm to BMS via Modbus
Topic: Communications systems and equipment.
Originally posted by Voulgaris Thanasis on 13 September, 2008 - 12:57 am
Protocol Modbus for fire alarm panel to BMS
New Replies:
By Roy Matson on 13 September, 2008 - 2:19 pm -
Not if you don't give us details. Make / Model of fire alarm panel Make/ model of Burner...
from the Automation List department...
Instrumentation signals
Topic: Application Questions and Problems
Originally posted by M. Perez on 13 September, 2008 - 1:33 am
Replacing terminal boxes and multiconductor cables in our plant. How to evaluate new technologies, and what are our options for viable solutions?
New Replies:
By Roy Matson on 13 September, 2008 - 2:18 pm -
It seems as though you need some sort of distributed I/O system (assuming you don't want to replace...
Topic: Application Questions and Problems
Posted by VRVR on 13 September, 2008 - 2:17 pm
We are facing a problem of Mark V controllers <R>, <S>, <T> whenever lightening strikes near by electrical switch yard.
from the Automation List department...
Control Instrumentation befor Semiconductor Era
Topic: Information resources, documentation.
Posted by Rushi Shroff on 13 September, 2008 - 2:16 pm
Time-line process automation
from the Automation List department...
Embedded systems training
Topic: Information resources, documentation.
Originally posted by P. Samuthira Pandi on 13 May, 2004 - 6:46 pm
I want to have a training in embedded systems in India.
New Replies:
By samy on 13 September, 2008 - 2:15 pm -
Thanks to this forum Taking feedback from this forum I searched for embedded systems training in...
from the Automation List department...
Fault tolerent ethernet
Topic: Communications systems and equipment.
Posted by Communication on 13 September, 2008 - 2:15 pm
What's differ between Fault tolerent ethernet and ethernet?
from the Automation List department...
Embedded systems in Hyderabad
Topic: Information resources, documentation.
Originally posted by suresh on 30 June, 2006 - 10:17 pm
Would u suggest any institution for embedded systems in hyderabad?
New Replies:
By samy on 13 September, 2008 - 2:15 pm -
I think the best training institute for embedded systems course in hyderabad is Sigma Solutions. ...
By rakesh on 13 September, 2008 - 12:55 am -
You can go for ISM or Vector. Regards, rakesh...
from the Automation List department...
Serious Troubles with Embedded Hardware
Topic: Software, including programming, OS issues, etc.
Originally posted by Rushi Shroff on 12 September, 2008 - 1:46 am
Encountering serious problems with hardware issues
New Replies:
By Curt Wuollet on 13 September, 2008 - 2:14 pm -
Simple if you have the background and only superficially understandable if you don't, embedded...
from the Software department...
Modbus protocol and Java
Topic: Continuous process industries, DCS questions.
Originally posted by GM on 13 September, 2008 - 12:03 am
Connecting to a remote meter
New Replies:
By Michael Griffin on 13 September, 2008 - 2:12 pm -
Type "modbus java" into Google, and the first thing that comes up is:...
from the Automation List department...
Is there a need for Remote Control in automation?
Topic: Software, including programming, OS issues, etc.
Originally posted by CAC on 12 September, 2008 - 1:28 am
I am investigating the need for remote control products within automation.
New Replies:
By CAC on 13 September, 2008 - 2:11 pm -
Hi Thank you for your reply. Is Linux very common in this industry, or is it mostly Windows? We...
By Michael Griffin on 13 September, 2008 - 2:10 pm -
From your description, its hard to see what you are doing that isn't already built into standard...
By Marc Sinclair on 13 September, 2008 - 12:59 am -
Hi, Remote control has very little meaning as far as LINUX is concerned, as it is simple to ssh...
Topic: Application Questions and Problems
Originally posted by Info Seeker on 10 September, 2008 - 1:05 am
Trying to reason out why tripping of a Gas Turbine is not considered on LUBE OIL TANK level LOW LOW.
New Replies:
By Info Seeker on 13 September, 2008 - 1:59 am -
Great response. Thanks CSA for a wonderful explanation....
from the DCS department...
PCS7 Asset Management
Topic: Continuous process industries, DCS questions.
Originally posted by QuITtED on 8 September, 2008 - 5:01 pm
Plant Asset Management capability of the Simatic PCS7
New Replies:
By Ronald on 13 September, 2008 - 1:48 am -
1. SIMATIC PCS 7 System, Device and Plant asset management is an option that integrates with the...
from the Automation List department...
IEC 62056-21 to MODBUS or DNP
Topic: Engineering and workplace issues.
Posted by Eduardo Wong on 13 September, 2008 - 1:28 am
I need help to convert from protocol IEC 62056-21 to MODBUS or DNP, it's for a thermoelectrical plant.
from the gas turbines department...
MarkV controls
Topic: Application Questions and Problems
Originally posted by ankarao on 8 September, 2008 - 4:52 pm
MarkV controls problem
New Replies:
By ankarao on 13 September, 2008 - 1:26 am -
Thanks for the reply. We confirmed that cable swapping has not taken place. If that is the...
from the Maintenance department...
Power plant journeyman mechanic information
Topic: Engineering and workplace issues.
Posted by Mike on 13 September, 2008 - 1:24 am
Looking for info on types of equipment used in modern power plants.
from the Automation List department...
Relationship Between Ethernet and TCP/IP
Topic: Local and wide area networking in factory automation.
Originally posted by Rushi Shroff on 11 September, 2008 - 1:34 am
Ethernet & TCP/IP
New Replies:
By Dick Caro on 13 September, 2008 - 1:22 am -
Ethernet is defined by IEEE 802.3 standard, that is also ISO 8802-3. This defines the physical...
By James Ingraham on 13 September, 2008 - 12:14 am -
"Ethernet & TCP/IP: What is the exact difference or relationship between these two?" ...
from the Control Systems department...
Dual Monitors
Topic: Human-Machine Interface and SCADA.
Posted by Roy Matson on 13 September, 2008 - 1:21 am
Dual Displays on RSView & DeltaV
from the Theory of operation department...
Compound Motor
Topic: Engineering and workplace issues.
Originally posted by Oriel Babilonia on 11 September, 2008 - 1:33 am
Connection types in a compound engine
New Replies:
By Oriel Babilonia on 13 September, 2008 - 1:19 am -
Excuse me my bad redaction, however I am glad that you understood the right message. Can you give...
from the Reviews and Opinion Requested department...
VFD Ethernet Comm
Topic: Communications systems and equipment.
Originally posted by PaulEE on 11 September, 2008 - 12:27 am
Can anyone direct me to a web site that reviews and/or compares the VFDs of different manufacturers, with particular interest in the Ethernet communication feature?
New Replies:
By B on 13 September, 2008 - 12:53 am -
I won't repeat but I will agree with most of what has been said thus far. I will say it's not gobs...
By Ranjan Acharya on 13 September, 2008 - 12:30 am -
The problem here is that there is not one kind of Industrial Ethernet. -- I would pick the...
from the voltage department...
DC-DC Converter
Topic: Sensor technologies.
Originally posted by Russ Miller on 12 September, 2008 - 1:49 am
Looking for a dc24v to dc5v converter, screw-terminal, din-rail mount.
New Replies:
By Marc Sinclair on 13 September, 2008 - 12:49 am -
Hi, I use the Sunpower SDS 030v05 (http://www.sunpower-uk.com) to power 5v wireless network...
from the instrumentation department...
PI thread in Excel
Topic: Continuous process industries, DCS questions.
Posted by bhushan_mpc on 13 September, 2008 - 12:48 am
What is PI thread in DeltaV
from the Automation List department...
Compressor bleed valve
Topic: Application Questions and Problems
Posted by Pritpal Singh on 13 September, 2008 - 12:47 am
Compressor bleed valve problems in power plant.
from the instrumentation department...
Tapping on impulse line
Topic: Continuous process industries, DCS questions.
Posted by bhushan_mpc on 13 September, 2008 - 12:46 am
Transmitter impulse tubing tapping on process line
from the instrumentation department...
Calibration range
Topic: Continuous process industries, DCS questions.
Originally posted by prash on 12 September, 2008 - 12:49 am
For transmitters, why is the calibration range always mentioned in mm of WC?
New Replies:
By Ulf on 13 September, 2008 - 12:42 am -
About Water Column: When I started my career (25 yrs ago) in instrumentation water filled U-tubes,...
By Roy Matson on 13 September, 2008 - 12:30 am -
The range can be in any pressure unit. Your calibration range is whatever you want to measure. ...
from the GENERATION department...
Load Dispatch Executive
Topic: Engineering and workplace issues.
Posted by Pritpal on 13 September, 2008 - 12:42 am
Gas Turbine Compressor bleed valves
from the electrical department...
Optimal placement of DG on radial feeder
Topic: Engineering and workplace issues.
Posted by krishnanmurthi on 13 September, 2008 - 12:39 am
How can I write Matlab code and Simulink for placement of Distributed Generation in radial feeder?
from the Automation List department...
Can Siemens PCS7 be considered as a True DCS?
Topic: Application Questions and Problems
Originally posted by Dr. R. Murugesan on 24 March, 2007 - 10:17 am
All the Vendors claim their offering is a true DCS and 'can perform the assigned role'...
New Replies:
By Muhammad AlHawamy on 13 September, 2008 - 12:37 am -
I have been working in a consultancy firm. I have happened to evaluate bids for my clients. Based...
from the Automation List department...
Johnson Controls DX9100 Protocol
Topic: Software, including programming, OS issues, etc.
Originally posted by wclai97 on 16 August, 2008 - 12:57 am
DX9100 checksum/BCC calculation
New Replies:
By wclai97 on 13 September, 2008 - 12:33 am -
Hello Victor, Thanks for your reply. Beside the 2 checksum characters you mention. I think there...
from the Electrical engineer department...
SAP training centre in Pune
Topic: Information resources, documentation.
Originally posted by Karan Ray on 25 January, 2007 - 2:02 am
I am electrical engineer & want to learn SAP.
New Replies:
By sriram on 13 September, 2008 - 12:29 am -
Hi, You can contact me @ nsriram16 at gmail. com for SAP B1 related queries....
Topic: Information resources, documentation.
Originally posted by chiranjeevee on 10 January, 2005 - 7:50 pm
tell about the learning centers offering embedded course in chennai.
New Replies:
By Kathir on 13 September, 2008 - 12:25 am -
IBIN Technology solutions are providing solutions in embedded systems. I know they are providing...
from the Automation department...
Ethernet/IP devices
Topic: Local and wide area networking in factory automation.
Originally posted by siva on 15 July, 2008 - 12:52 am
Need some details about Ethernet/IP devices
New Replies:
By Ranjan Acharya on 13 September, 2008 - 12:15 am -
I'm not quite sure what you are asking. But, have a look at Comtrol (http://www.comtrol.com/). ...
from the Automation List department...
Need to step-up control system security
Topic: Continuous process industries, DCS questions.
Originally posted by Fluoronator on 27 August, 2008 - 9:59 pm
What's the best approach to network security in a control system environment?
New Replies:
By Ranjan Acharya on 13 September, 2008 - 12:13 am -
There are several steps involved in locking down a control system. This link is old...
from the Automation List department...
Intrinsically safe terminals
Topic: Continuous process industries, DCS questions.
Originally posted by ian on 5 September, 2008 - 8:03 pm
Terminal colors
New Replies:
By Subramaniam Janakiraman on 13 September, 2008 - 12:09 am -
ISA RP 12.6/NEC 504 calls for light blue colored terminals at the field JBs for IS circuits as well...
from the Instrument and Control systems department...
New "DCS" control system selection
Topic: Continuous process industries, DCS questions.
Originally posted by George Whaley on 3 September, 2008 - 12:24 am
Requesting member feedback for the replacement selection of an existing petrochemical control system "DCS".
New Replies:
By RJ on 13 September, 2008 - 12:08 am -
I like the DCSs from ABB. Freelance for smaller systems and 800xA for larger systems. The...
from the DLN Tuning department...
DLN Tuning gas turbines
Topic: Engineering and workplace issues.
Originally posted by Brian on 9 September, 2008 - 12:05 am
Can anyone explain to me the meaning of "DLN system tuning"?
New Replies:
By CSA on 13 September, 2008 - 12:03 am -
The exact process of tuning a machine with DLN-I or DLN-2.n combustors is slightly different, but...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.