Friday, September 19, 2008
from the Automation List department...
Fr. 9E Hydraulic Oil discharge pr trouble
Topic: Engineering and workplace issues.
Posted by anonymous on 19 September, 2008 - 11:59 pm
Fr. 9E GE gas turbine main hydraulic oil discharge pressure get change suddenly without leakage and any other reason.
from the no speak modbus department...
Modbus for Dummies
Topic: Information resources, documentation.
Originally posted by Svstech1968 on 19 September, 2008 - 1:29 am
Trying to learn Modbus from ground up. Looking for good, understandable resources.
New Replies:
By Mark on 19 September, 2008 - 11:58 pm -
You should find this page helpful: http://www.simplymodbus.ca/FAQ.htm...
from the Industrial department...
PID Controller
Topic: Continuous process industries, DCS questions.
Posted by Dinesh Rode on 19 September, 2008 - 11:47 pm
Time proportional PID
from the I need to know department...
Binary Code
Topic: Programming languages.
Originally posted by ME on 19 February, 2002 - 5:14 pm
I want to learn Binary code...
New Replies:
By Andy R on 19 September, 2008 - 11:46 pm -
Binary is EASY. VERY easy. It's just getting the hang of it, that's all. Okay, let's take 111...
from the Automation List department...
Communication problem between a PC and a SLC 5/03
Topic: PLCs and related questions.
Originally posted by Adekunle on 27 August, 2008 - 10:04 pm
cannot establish communication between a PC connected and PLC linked through a RS232 port after downloading the program.
New Replies:
By Roy Matson on 19 September, 2008 - 11:46 pm -
Hi, Why not just change the connector on the cable you have to suit your laptop? Are you also...
from the Operations department...
Some queries about gas turbine
Topic: Engineering and workplace issues.
Posted by sunny on 19 September, 2008 - 11:42 pm
An exhaust diffuser converts velocity of flue gases into static pressure so that flue gases coming out at high velocity of a GT exhaust do not damage HRSG components?
from the Automation List department...
Transformer connections
Topic: Information resources, documentation.
Originally posted by safeer on 19 September, 2008 - 1:34 am
What difference can it make if I connect a transformer primary with two phases from a three phase supply?
New Replies:
By Roy Matson on 19 September, 2008 - 11:41 pm -
Yes, it's OK to connect between two phases provided you protect both primaries with a fuse or 2...
from the Automation List department...
Dumb (miniature) pressure calibration
Topic: Sensor technologies.
Originally posted by gh. Alizadeh on 19 September, 2008 - 12:55 am
How to calibrate SITRANS pressure transmitter?
New Replies:
By Bob Peterson on 19 September, 2008 - 11:40 pm -
Pretty much the same way you calibrate smart ones except you have to adjust the span and zero with...
from the RS department...
Modbus RTU RS 485
Topic: Communications systems and equipment.
Originally posted by Pieter on 18 September, 2008 - 1:26 am
Maximum length of RS 485 cable between 2 devices
New Replies:
By Roy Matson on 19 September, 2008 - 11:37 pm -
I see several posters give 1200 meters. I am not disputing that, but is it really practical? I...
By Issac Issachar on 19 September, 2008 - 1:48 am -
"No maximum bus length is given for RS485, but ends up around 1200 meters at 200kbps or 50...
By VAM on 19 September, 2008 - 1:35 am -
The longest distance supported by the serial communications is 100ft, normally that value applies...
By Patrick on 19 September, 2008 - 1:12 am -
Hi there, The cable length is depended on what baud rate that is used. For more info: ...
By Tom Chubb on 19 September, 2008 - 1:08 am -
It's dependent on the speed. Can't remember off the top of my head....
By Raju D.S on 19 September, 2008 - 1:06 am -
By using RS-485, a maximum of 32 devices can be connected in daisy chain network. And the maximum...
from the Automation List department...
AB Panelview communications
Topic: PLCs and related questions.
Originally posted by Don on 19 September, 2008 - 1:44 am
Communications issue
New Replies:
By Bob Peterson on 19 September, 2008 - 11:36 pm -
You can't, but AB has several options to do this. They aren't free but are not real pricey either....
from the Instrumentation department...
Extension Neck
Topic: Sensor technologies.
Posted by Prashanth on 19 September, 2008 - 11:33 pm
Could anyone please explain the actual requirement of Extension Neck in RTD sensors?
from the Automation List department...
Is there a need for Remote Control in automation?
Topic: Software, including programming, OS issues, etc.
Originally posted by CAC on 12 September, 2008 - 1:28 am
I am investigating the need for remote control products within automation.
New Replies:
By CAC on 19 September, 2008 - 11:32 pm -
Hi, and thank you for your input. Your suggestions are very valuable to me, so this is great....
from the Projects department...
Cross Current In Synchronized Generators
Topic: Engineering and workplace issues.
Originally posted by SAA on 18 September, 2008 - 1:37 am
Cross current in synchronized generators neutral cable
New Replies:
By blackstoneboy on 19 September, 2008 - 11:31 pm -
Do you mean the gensets are loaded?...
By blackstoneboy on 19 September, 2008 - 2:04 am -
Hi there.. What is the rated power of your generators?? Try to lower the droop from the AVR to...
Topic: Engineering and workplace issues.
Originally posted by speedtronic on 18 September, 2008 - 1:35 am
Why there is no exhaust (duct) back pressure high protection for Frame9E GT (MarkIV control in my case)?
New Replies:
By speedtronic on 19 September, 2008 - 11:28 pm -
Thanks CSA for your answer. I have mentioned in my previous post that all our GTs run in...
By CSA on 19 September, 2008 - 2:04 am -
Different packagers of GE-design heavy duty gas turbines had different philosophies regarding unit...
from the Operations department...
Gas Turbine Excitation System
Topic: Engineering and workplace issues.
Originally posted by cyclones on 14 September, 2008 - 6:54 pm
With reference to GE frame9E GT Excitation system(rotaduct/rotating diodes), why DC excitation voltage is not directly applied to rotor?
New Replies:
By blackstoneboy on 19 September, 2008 - 11:24 pm -
We cannot apply DC voltage directly to it since it is rotating....
from the Automation List department...
Choosing PCS7 DCS for steam power plant
Topic: Engineering and workplace issues.
Originally posted by Mikas on 24 August, 2008 - 3:00 pm
Consider pros and cons of PCS7 as DCS for power plants.
New Replies:
By josef on 19 September, 2008 - 11:24 pm -
Comparable to the CEMAT or BRAUMAT library is the PPL (Premium Plant Library) for PCS7. This...
from the Tuning department...
DLN 1 Tuning
Topic: Engineering and workplace issues.
Originally posted by Jeff on 17 September, 2008 - 2:28 am
DLN1 Tuning
New Replies:
By CSA on 19 September, 2008 - 2:12 am -
One needs to be very careful when changing splits; very careful. And, this condition is also...
from the Automation List department...
How can I control reverse power flow?
Topic: Motion control, servos, steppers, etc.
Originally posted by Rob on 17 September, 2008 - 2:46 am
Have a waterfall churning out 12KW from an induction generator. My local utility gave me a new electronic meter that records the absolute kWh. So now when I send them excess power they charge me for the privilege! My old spinning disk meter was more fair even with an anti reverse ratchet!
New Replies:
By blackstoneboy on 19 September, 2008 - 2:12 am -
Try to check power factor of your system. If the PF goes capacitive, definitely you will have...
Topic: Engineering and workplace issues.
Originally posted by shahvir on 18 September, 2008 - 12:44 am
Effect of varying the driving torque of single alternator on load voltage (load connected is purely RESISTIVE).
New Replies:
By blackstoneboy on 19 September, 2008 - 2:07 am -
Hi... As we always observed, the frequency is directly proportional to the voltage. If we vary...
from the Electrical Engineering department...
Unequal load sharing of generators
Topic: Engineering and workplace issues.
Originally posted by Nimra on 23 July, 2008 - 1:52 am
I have a question about unequal load sharing of generators.
New Replies:
By blackstoneboy on 19 September, 2008 - 2:01 am -
Hi Nimra. What is the controller you are using when you do paralleling?? You should have master...
from the What goes wrong?? department...
GT Fogging - reduced output
Topic: Continuous process industries, DCS questions.
Originally posted by Kielland on 18 September, 2008 - 12:45 am
Output reduced 10% with fogging. What can be the possible reason?
New Replies:
By CSA on 19 September, 2008 - 1:52 am -
This question has been asked before; see this thread...
from the Automation List department...
Integration of Control Systems and IT
Topic: Engineering and workplace issues.
Originally posted by Rushi Shroff on 18 September, 2008 - 1:42 am
The role of control systems engineering
New Replies:
By Curt Wuollet on 19 September, 2008 - 1:51 am -
As long as you have a loop a Bode plot applies. As long as you sample, Nyquist applies. Automatic...
By CTTech on 19 September, 2008 - 1:47 am -
It seems that you have already formed an opinion. In the old analog control systems, you may be...
from the Automation List department...
Fieldbus communication with PC or SBC
Topic: Local and wide area networking in factory automation.
Posted by Gil Lund on 19 September, 2008 - 1:45 am
Looking for options for hardware/software that interface Fieldbus sensors to a Windows/Linux PC or a SBC running an RTOS.
Topic: Application Questions and Problems
Originally posted by VRVR on 13 September, 2008 - 2:17 pm
We are facing a problem of Mark V controllers <R>, <S>, <T> whenever lightening strikes near by electrical switch yard.
New Replies:
By CTTech on 19 September, 2008 - 1:43 am -
This is what I find interesting. C core is not part of the power loss. Although, ALL cores are fed...
By Tushar on 19 September, 2008 - 1:32 am -
I think processor's (R, S, T) toggle switches in <PD> core are not grounded. Please check the...
from the Automation List department...
ABB Process Portal A
Topic: Software, including programming, OS issues, etc.
Originally posted by Viktor Tadjer on 17 September, 2008 - 2:39 am
Upgrade of AB Process Portal A
New Replies:
By Rob on 19 September, 2008 - 1:40 am -
The answer to both your questions is of course Yes. You can upgrade any version of PPA and the...
from the serious department...
How to use LCC/DCC keypad of MKV processor
Topic: Engineering and workplace issues.
Posted by Faraz on 19 September, 2008 - 1:39 am
I would like to know how to use LCC/DCC keypad.
from the IT Department department...
I need a Modbus RTU Overview
Topic: Information resources, documentation.
Originally posted by Nick Jacobi on 16 September, 2008 - 12:17 am
A request for information about Modbus RTU
New Replies:
By Nick Jacobi on 19 September, 2008 - 1:37 am -
Thanks everybody for the replies, this should be more than enough information to go on. If there's...
from the Automation List department...
Mark V
Topic: Application Questions and Problems
Posted by TUSHAR on 19 September, 2008 - 1:36 am
Ex-2k communication
from the Automation List department...
Regenerative power supply
Topic: Engineering and workplace issues.
Posted by menon on 19 September, 2008 - 1:34 am
I am trying to simulate a regenerative power supply using Simplorer.
from the Mark V department...
Mark V HMI Upgrade
Topic: Human-Machine Interface and SCADA.
Originally posted by dinster on 18 September, 2008 - 1:34 am
Mark V HMI upgrade possibility?
New Replies:
By CSA on 19 September, 2008 - 1:32 am -
dinster, I think you have two options: Buy a new HMI from GE, or buy one of the third-party...
from the Automation List department...
Calculating an average value of the wind direction
Topic: Application Questions and Problems
Originally posted by Ville on 18 May, 2005 - 7:46 pm
How do I calculate the average value of the wind direction when 0° and 360° are the same?
New Replies:
By Robert Scott on 19 September, 2008 - 1:14 am -
Rik, I tried some examples using your eigen-vector method and using the method I proposed: ...
from the instrumentation department...
PID tuning help
Topic: Motion control, servos, steppers, etc.
Originally posted by pk on 8 September, 2008 - 4:57 pm
Oscillations in control system.
New Replies:
By Hans H. Eder on 19 September, 2008 - 1:10 am -
Integral time still seems very low to me (of course, without having seen your response curves)....
from the instrumentation department...
PI thread in Excel
Topic: Continuous process industries, DCS questions.
Originally posted by bhushan_mpc on 13 September, 2008 - 12:48 am
What is PI thread in DeltaV
New Replies:
By Graham Burnikell on 19 September, 2008 - 1:08 am -
PI is a propriety Data Historian from the Vendor OSISoft (http://www.osisoft.com). It has been used...
from the Instrumentation department...
Flow measurements on low gas pressures.
Topic: Continuous process industries, DCS questions.
Originally posted by Prashant Wakhale on 20 July, 2008 - 1:08 pm
Flow measurements are not constant in the C2H2 pipeline.
New Replies:
By Rohit Chandak on 19 September, 2008 - 1:04 am -
There are few technologies that can handle this application with perfection. VERABAR Flow Element,...
from the Automation List department...
GE Fanuc CNC 16-TB interface
Topic: Human-Machine Interface and SCADA.
Originally posted by Michael Batchelor on 12 September, 2008 - 11:37 pm
Empty summary
New Replies:
By Joern on 19 September, 2008 - 1:04 am -
Fanuc's Ethernet based protocol is called Focas. As far as I know, there is no OPC server...
from the MAINTENANCE department...
MELSEC F1-60 MR
Topic: PLCs and related questions.
Originally posted by RAJENDRA on 18 September, 2008 - 1:29 am
Having problem in PLC giving CPU error.
New Replies:
By zahid on 19 September, 2008 - 1:01 am -
Replace the battery and reprogram the CPU. ...
from the Automation List department...
Steam flowmeter
Topic: Application Questions and Problems
Posted by john on 19 September, 2008 - 1:00 am
Can I measure steam flow using smart ld301 tramsmitter?
from the Instrumentation department...
Positive Displacement Type Flowmeter
Topic: Engineering and workplace issues.
Originally posted by sanjib on 5 September, 2008 - 9:07 pm
Installation of Positive type Flow-Meter
New Replies:
By Rohit Chandak on 19 September, 2008 - 1:00 am -
Let me have your details to send installation manual on our PD Meter device which should help you....
from the Automation List department...
V-Cone Flowmeter
Topic: Continuous process industries, DCS questions.
Originally posted by Ward Feldmann on 22 June, 2004 - 2:38 pm
Does anyone know of a manufacturer for V-cone flowmeters?
New Replies:
By Rohit Chandak on 19 September, 2008 - 12:59 am -
There are few companies in China & Hitrol (I think I spelled it correctly) in South Korea which...
from the Automation List department...
Compressor bleed valve
Topic: Application Questions and Problems
Originally posted by Pritpal Singh on 13 September, 2008 - 12:47 am
Compressor bleed valve problems in power plant.
New Replies:
By Ero on 19 September, 2008 - 12:57 am -
Hi, We had some problem with CDP bleed valve last time. I checked servo controller and again...
from the Automation List department...
What is the sin-cos encoder phase angle?
Topic: Sensor technologies.
Originally posted by Fabri on 17 September, 2008 - 2:24 am
About encoder in brushless motor
New Replies:
By Fabri on 19 September, 2008 - 12:56 am -
>Are you talking about phasing the motor >to find commutation? < I don't know. The...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.