Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
We have only two things to worry about: That things will never get
back to normal, and that they already have.
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Tuesday, September 30, 2008
from the Instrumentation department...
Protool RT
Topic: Human-Machine Interface and SCADA.
Posted by dhoms on 30 September, 2008 - 10:17 pm
Network set-up in 2 S7-300 CPU and Protool RT station PC.
from the Forum department...
ControlLogix vs Quantum PLCs
Topic: PLCs and related questions.
Originally posted by Ryno83 on 29 September, 2008 - 10:58 pm
Pros and cons between ControlLogix and Quantum
New Replies:
By James Ingraham on 30 September, 2008 - 8:30 pm -
As a machine builder, I would no-quote a job if asked to use Quantum. If I were spec'ing machinery...
By aggattapauer on 30 September, 2008 - 4:23 pm -
In my opinion you should upgrade the PLC 5, of course, with ControlLogix 5000 and TI with Schneider...
from the Mentinance department...
Telemecanique TSX47
Topic: PLCs and related questions.
Originally posted by waliedam on 28 September, 2008 - 11:03 am
I need software for TSX47-10 & PL7-2/TSX17
New Replies:
By aggattapauer on 30 September, 2008 - 5:09 pm -
You might use a virtual PC platform as VMware by installing virtual OS/2 WARP. For the...
from the Forum department...
Modbus communication
Topic: Communications systems and equipment.
Originally posted by sunil on 29 September, 2008 - 12:03 pm
I am trying to communicate with ENERCON CONZERV ENERGY METER EM6434 having RS485 2 wire connection using SCHNEIDER TWIDO PLC and RS485 card inserted in port 2.
New Replies:
By aggattapauer on 30 September, 2008 - 5:00 pm -
First: you MUST read %MW because of the Modbus protocol. Second: In the Help of Twidosoft, you...
By chud on 30 September, 2008 - 4:57 am -
This is an extract from the manual: "Single, double length and floating words are stored in...
from the Forum department...
Scripting in Factorylink
Topic: Human-Machine Interface and SCADA.
Posted by marcy on 30 September, 2008 - 1:52 pm
I can't find an event to run my code in.
from the Instrument department...
F&G protection for a diesel generator
Topic: Power generation equipment control.
Originally posted by PC on 27 September, 2008 - 9:02 am
F&G protection for a diesel generator
New Replies:
By Bill Schwarz on 30 September, 2008 - 1:09 pm -
In my facility, our insurer requires us to install sprinkler systems over the diesel fuel tanks. ...
from the Automation List department...
Communication os Yokogawa Centum DCS to PC
Topic: Continuous process industries, DCS questions.
Originally posted by Mihir Ramkrishna on 20 September, 2008 - 1:28 pm
We want to establish communication between Yokogawa Centum DCS with a PC over serial link
New Replies:
By Pritesh Patel on 30 September, 2008 - 1:03 pm -
Dear Mihir, Myself & Prakash have already tested this functionality using some MODBUS...
from the automation department...
Fiber optic system versus Masterbus300
Topic: PLCs and related questions.
Posted by pk on 30 September, 2008 - 11:50 am
We want to change the Masterbus300.
from the automation department...
ABB MB300 communication
Topic: PLCs and related questions.
Originally posted by pk on 25 September, 2008 - 4:26 am
Very slow communication
New Replies:
By pk on 30 September, 2008 - 11:44 am -
Thanks friends, Finally I found the problem in the cable and changed it partially....
By Bob on 30 September, 2008 - 8:42 am -
Hello, It sounds as if you move your HMI to location 3, then you can communicate... but now not...
from the Automation List department...
Microcontroller based digital DC motor speed control
Topic: Motion control, servos, steppers, etc.
Originally posted by kasturi on 27 October, 2007 - 1:47 am
Block diagram and how to use microcontroller
New Replies:
By ravi chandar on 30 September, 2008 - 9:59 am -
Hi, I am ravi chandar doing my B-Tech IV year. Hey, will you first please explain to me about...
from the Loss of vaccum department...
VCBs
Topic: Engineering and workplace issues.
Originally posted by Aseem on 25 June, 2008 - 11:24 pm
What if vacuum is lost on VCBs?
New Replies:
By Phil Corso on 30 September, 2008 - 8:29 am -
Elizabeth... I was not able to obtain a copy of The DOBLE paper, because I am not a member, nor am...
Topic: Human-Machine Interface and SCADA.
Posted by Pankaj on 30 September, 2008 - 7:11 am
PanelView Plus communication to Emerson Ovation controller.
from the Forum department...
Orifice plate issue
Topic: Continuous process industries, DCS questions.
Originally posted by Young Engineer on 29 September, 2008 - 5:37 am
Orifice plate issue
New Replies:
By Roy Matson on 30 September, 2008 - 6:53 am -
You don't say where the impulse lines are plugging, is it right at the orifice connection or in the...
from the Forum department...
Searching for a OSS SCADA
Topic: Software, including programming, OS issues, etc.
Originally posted by Ernesto Silva on 24 September, 2008 - 10:08 am
I'm searching for a open source SCADA system, any ideas?
New Replies:
By pvbrowser on 30 September, 2008 - 4:46 am -
>I'm talking about a >package that's easy to install, >configure, and get going. < ...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!