Thursday, October 2, 2008
from the Forum department...
Scripting in Factorylink
Topic: Human-Machine Interface and SCADA.
Originally posted by marcy on 30 September, 2008 - 1:52 pm
I can't find an event to run my code in.
New Replies:
By Gustavo A. Valero P. on 2 October, 2008 - 8:54 pm -
Hi, If you are using the real VBA in FactoryLink 7.2 or higher and want to run any script (e.g....
Topic: Power generation equipment control.
Originally posted by James on 2 October, 2008 - 1:03 am
Advantages of Mark VI and Mark V over Mark IV?
New Replies:
By MIKEVI on 2 October, 2008 - 8:15 pm -
James, We have 2 Frame 5 gas turbines in service since 1985 that we upgraded from MKIV to MKVI...
By CSA on 2 October, 2008 - 8:14 pm -
The Mark V Speedtronic is no longer being produced by GE and they have issued an 'end-of-life'...
from the Forum department...
ControlLogix vs Quantum PLCs
Topic: PLCs and related questions.
Originally posted by Ryno83 on 29 September, 2008 - 10:58 pm
Pros and cons between ControlLogix and Quantum
New Replies:
By James Ingraham on 2 October, 2008 - 7:14 pm -
Miguel Lage: "I have been working with Quantum, Premium, Momentum and M340 for the last 10...
By KirkC on 2 October, 2008 - 2:39 am -
James, I'd be starving now if I didn't make new Modicon applications. So now you've READ that at...
from the Forum department...
Reading Log files from CAN bus
Topic: Application Questions and Problems
Posted by Azzi on 2 October, 2008 - 7:06 pm
How we can read log files via CAN bus?
from the Hopefull department...
DNP3
Topic: PLCs and related questions.
Originally posted by Matt on 14 December, 2006 - 9:34 pm
Do Siemens S7-200 and S7-300 PLCs have a communictions module for DNP3? If not, how do I get them to talk on with the DNP3 Protocol?
New Replies:
By Evandro Vizicato on 2 October, 2008 - 6:24 pm -
Hi, Prosoft has a gateway DNP3/Profibus that you can use. ...
Topic: Human-Machine Interface and SCADA.
Originally posted by Pankaj on 30 September, 2008 - 7:11 am
PanelView Plus communication to Emerson Ovation controller.
New Replies:
By Evandro Vizicato on 2 October, 2008 - 6:04 pm -
First you need to upgrade the firmware of Pv-Plus to include Kepserver driver for Modbus Plus. ...
from the automation department...
Siemens transducer SIMSEAS calibration
Topic: Sensor technologies.
Originally posted by paru on 12 August, 2008 - 1:35 am
I am trying to calibrate the voltage and current transducer, but I'm not able to do it.
New Replies:
By Control Freak on 2 October, 2008 - 4:09 pm -
Switch to a Time Mark Corp transducer. We've had so many problems with the Siemens ones....
from the Forum department...
Wide area economic load dispatch sytem
Topic: Power generation equipment control.
Posted by Mikas on 2 October, 2008 - 2:52 pm
Want to know more about wide area economic load dispatch system.
from the Automation List department...
V-Cone Flowmeter
Topic: Continuous process industries, DCS questions.
Originally posted by Ward Feldmann on 22 June, 2004 - 2:38 pm
Does anyone know of a manufacturer for V-cone flowmeters?
New Replies:
By Jim Martin on 2 October, 2008 - 2:41 pm -
Again, if you allow others to promote Preso, ABB, the Chinese manufacturer, McCrometer, etc., I...
from the Automation List department...
Compressor bleed valve
Topic: Application Questions and Problems
Originally posted by Pritpal Singh on 13 September, 2008 - 12:47 am
Compressor bleed valve problems in power plant.
New Replies:
By francis on 2 October, 2008 - 1:31 pm -
This problem is very present before the cleaning off line. You must drain the filter water/air...
from the Forum department...
Modbus communication
Topic: Communications systems and equipment.
Originally posted by sunil on 29 September, 2008 - 12:03 pm
I am trying to communicate with ENERCON CONZERV ENERGY METER EM6434 having RS485 2 wire connection using SCHNEIDER TWIDO PLC and RS485 card inserted in port 2.
New Replies:
By aggattapauer on 2 October, 2008 - 12:38 pm -
Send me the program. aggattapauer at jumpy . it...
from the Allen Bradley department...
PLC 2 with PCMK /A
Topic: PLCs and related questions.
Posted by mwildin1 on 2 October, 2008 - 11:36 am
How to get a 1784-PCMK Version A card to work with AB6200 software in DOS
from the Instrumentation department...
SCADA & Telecom Documentation
Topic: Engineering and workplace issues.
Posted by c.k.visavadiya on 2 October, 2008 - 9:45 am
How to register (record) SCADA Telecom documentation
from the automation department...
Fiber optic system versus Masterbus300
Topic: PLCs and related questions.
Originally posted by pk on 30 September, 2008 - 11:50 am
We want to change the Masterbus300.
New Replies:
By pk on 2 October, 2008 - 7:52 am -
Thank you friend, But can you tell me in some more detail please? We need some converter, like...
from the Forum department...
Convert Modbus to Fieldbus Foundation
Topic: Human-Machine Interface and SCADA.
Originally posted by Dave Mira on 1 October, 2008 - 4:24 pm
Explanation of Fieldbus required.
New Replies:
By dchartier on 2 October, 2008 - 6:39 am -
Hello; The best information on Fieldbus Foundation that I have found on the Web comes from...
By Engine on 2 October, 2008 - 4:03 am -
Hello there, Have you tried looking into Emerson Rosemount 3420 Series: Fieldbus Interface...
from the Forum department...
Mark 6 NTP configuration
Topic: Human-Machine Interface and SCADA.
Originally posted by AmAm on 1 October, 2008 - 3:25 am
What is the best configuration for NTP for master HMI and its clients?
New Replies:
By AmAm on 2 October, 2008 - 5:29 am -
First, thanks a lot for your fast reply. I have searched in the manual of both NTP and NTP...
By Zhuong on 2 October, 2008 - 3:42 am -
Does Mark VI access NTP Servers (NTP Servers: 209.81.9.7 or 207.46.130.100) via open internet to...
from the Frustration department...
DCS problem
Topic: Human-Machine Interface and SCADA.
Originally posted by Paul Seaman on 1 October, 2008 - 7:08 pm
DCS serial comms failure between DCS and RTU
New Replies:
By Rob on 2 October, 2008 - 3:43 am -
Yes. You can kill an Advant controller serial link. If the MODBUS link fails, the ABB Advant...
from the Automation List department...
Can Siemens PCS7 be considered as a True DCS?
Topic: Application Questions and Problems
Originally posted by Dr. R. Murugesan on 24 March, 2007 - 10:17 am
All the Vendors claim their offering is a true DCS and 'can perform the assigned role'...
New Replies:
By Magister on 2 October, 2008 - 1:57 am -
Wrong. 1/p * 1/p = (1/p)^2 - in case of series connection. Dual redundancy - parallel...
Topic: Continuous process industries, DCS questions.
Posted by Magister on 2 October, 2008 - 1:07 am
Need to produce high frequency pulse output signal on Yokogawa CS3000
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.