Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
"There was a boy called Eustace Clarence Scrubb, and he almost deserved
it."
-- C. S. Lewis, The Chronicles of Narnia
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Thursday, October 9, 2008
from the Automation List department...
Simplex Fire Alarm System 4100U
Topic: Software, including programming, OS issues, etc.
Originally posted by ANA on 5 June, 2005 - 10:08 am
Simplex Fire Alarm System 4100U Programming Software.
New Replies:
By Frank on 9 October, 2008 - 11:26 pm -
If you want a tech that is not factory certified programming on your 4100U you're nuts, Simplex...
from the Rosemount pressure switches department...
Rosemount Pressure Switch
Topic: Sensor technologies.
Originally posted by Hannibal Zzzz on 7 October, 2008 - 1:49 pm
I need a good pressure switch.
New Replies:
By FIG on 9 October, 2008 - 10:59 pm -
United Electric & CCS (custom control sensors) http://www.ccsdualsnap.com/compact.htm They...
from the Forum department...
Siemens Hydroranger problem
Topic: Continuous process industries, DCS questions.
Originally posted by Kevin on 8 October, 2008 - 8:53 am
4-20mA outputs keep going out on Siemens Hydroranger
New Replies:
By Issac Issachar on 9 October, 2008 - 9:30 pm -
Interesting, most analog problems manifest themselves on the input side, not the output side. How...
By wboyes on 9 October, 2008 - 2:12 pm -
Have you talked to Siemens? Something is clearly wrong... and it is unlikely to be the meter itself...
from the Forum department...
Load cell millivolt signal conditioner
Topic: Sensor technologies.
Originally posted by Simple68 on 25 September, 2008 - 3:20 am
Millivolt conversion from load cells
New Replies:
By Leonid on 9 October, 2008 - 5:58 pm -
Of course load cell isn't connected to PLC directly. Except Strain Gauge Transmitter with outputs...
from the Fustration department...
PL7-3 Conversion
Topic: PLCs and related questions.
Posted by Joe on 9 October, 2008 - 4:39 pm
How can I convert PLC-7 using X-TEL software running on OS2, to something that I can use with Windows-based programming software?
from the Automation and Instrumentation department...
Water Treatment Process Control and Instrumentation
Topic: Continuous process industries, DCS questions.
Originally posted by Jan Michael Albaran on 8 October, 2008 - 7:39 pm
Best/better approach for the water treatment instrumentation and automation...
New Replies:
By wboyes on 9 October, 2008 - 2:11 pm -
If you place the valve upstream of the meter, be sure it is a dead minimum of five times the...
By souane on 9 October, 2008 - 12:53 pm -
Yes, it's right if you place a valve before a magnetic flowmeter. It's better to place a ball...
from the contol department...
MKV LM
Topic: Application Questions and Problems
Originally posted by djedid on 7 October, 2008 - 11:32 am
I have Panel Mark V LM add alarm
New Replies:
By CSA on 9 October, 2008 - 1:49 pm -
If there are no spare alarms available in ALLOCSSP.ASG, then there are no spare alarms available. ...
from the Mechanical/Electrical department...
Motor/Drive for Radio Dish
Topic: Engineering and workplace issues.
Posted by Mohammed Ahmed on 9 October, 2008 - 11:58 am
Need help with choosing a motor/drive system appropriate for operating a radio dish for amateur radio astronomy.
from the PLC Conversion department...
How to convert PLC-2 to PLC-5 fast?
Topic: PLCs and related questions.
Originally posted by Me on 8 October, 2008 - 3:46 pm
Convert Allen Bradley PLC-2 to PLC-5. Software needed? not available... :(
New Replies:
By Michael Batchelor on 9 October, 2008 - 10:57 am -
There's not much better than plain old brute force. Open the file, and start rung by rung if you...
from the Forum department...
DCS powered vs. field powered
Topic: Power generation equipment control.
Originally posted by sonicjoe_xx on 8 October, 2008 - 6:42 am
What is the difference between DCS powered and field powered?
New Replies:
By Steve Yates on 9 October, 2008 - 10:55 am -
Basically the source of the loop power, i.e. from the DCS I/O card or a source of power local to...
By Don Lupo on 9 October, 2008 - 7:37 am -
I think your question is relating to powering a field transmitter. If the DCS powers the field...
from the Operation department...
Gas turbine GE Frame 9 purge air
Topic: Power generation equipment control.
Originally posted by A. Kumar on 7 October, 2008 - 6:15 am
What is the effect of closed purge air valves VA33-1 and VA33-2 on gas turbine running on fuel gas?
New Replies:
By CSA on 9 October, 2008 - 10:52 am -
A 2-3 MW loss of output on a Frame 9E (rated at approximately 120 MW) is a pretty significant load...
Topic: Application Questions and Problems
Originally posted by sairul on 7 October, 2008 - 10:43 pm
Selection of IS or non-IS cable to wire up devices.
New Replies:
By Steve Yates on 9 October, 2008 - 9:51 am -
Firstly, you need to decide whether the loop will be IS or not as there are other techniques that...
By Sairul Azali on 9 October, 2008 - 12:54 am -
Dear Steve, Thank you for your reply. My understanding of IS or non IS cable is as follows, and...
from the Automation List department...
Moore APACS / Wonderware Integration
Topic: Human-Machine Interface and SCADA.
Originally posted by Kenneth Poteete on 23 November, 2005 - 1:05 pm
What is needed to interface a Moore APACS system with a Wonderware HMI?
New Replies:
By A nony mouse on 9 October, 2008 - 9:05 am -
Incorrect - while the application you create is yours, the software it runs on is not. As with...
Topic: Human-Machine Interface and SCADA.
Posted by panqy82 on 9 October, 2008 - 8:33 am
How do I display "Message line format" list?
from the Instrument department...
PG mounting
Topic: Application Questions and Problems
Posted by PC on 9 October, 2008 - 8:05 am
PG mounting
from the Automation List department...
Eliwell Televis/Micronet protocol
Topic: Communications systems and equipment.
Originally posted by Priit on 31 May, 2008 - 1:05 am
Eliwell Televis RS485 network to industrial PLC.
New Replies:
By Paco Loco on 9 October, 2008 - 7:55 am -
Hi! Have you found this protocol? I'm interested too. Thank you....
from the GE Mark V turbine department...
Phase Shift Alarm
Topic: Power generation equipment control.
Posted by Lalith on 9 October, 2008 - 7:55 am
We have a AEES 230Vac, 1500 VA inverter with static switch for supplying frame 9 Mark V GE gas turbine.
from the Instrumentation department...
Calibration of SMART Transmitters
Topic: Information resources, documentation.
Originally posted by Nandan Banerjee on 17 September, 2008 - 2:39 am
How to calibrate any SMART transmitters without using HART communicator?
New Replies:
By S.gordon on 9 October, 2008 - 7:10 am -
HART communicator comes with a HART protocol software that you need to install in your PC. The...
from the Rockwell vs. Siemens department...
Need Comparison of Rockwell ControlLogix vs. Siemens 417H
Topic: The Business of Automation and Control
Posted by any on 9 October, 2008 - 5:36 am
Please send me said comparison.
from the Forum department...
Mark 6, servo valve calibration
Topic: Engineering and workplace issues.
Posted by AmAm on 9 October, 2008 - 5:33 am
Mark 6 servo valve calibration.
from the Forum department...
PLC Price List
Topic: PLCs and related questions.
Posted by aiks07 on 9 October, 2008 - 5:12 am
PLC price list urgent help!
from the Automation and Instrumentation department...
SCADA System
Topic: Continuous process industries, DCS questions.
Posted by Jan Michael Albaran on 9 October, 2008 - 4:53 am
Do I need to place/use indicators, chart recorder, etc. if I'll be using a SCADA?
from the Automation List department...
Controlling SCR time on and off with a 555 timer
Topic: Engineering and workplace issues.
Posted by Paul Pri on 9 October, 2008 - 1:42 am
Is there any way I can control the SCR time on and off with 555 timer?
from the Forum department...
Eexd or Eexe juction box
Topic: Engineering and workplace issues.
Originally posted by andrew on 8 October, 2008 - 2:53 am
is it possible to use Eexe junction boxes instead of Eexd JB's?
New Replies:
By Ranjan Acharya on 9 October, 2008 - 12:04 am -
From what I've seen over the years with hazardous environments, until you've seen a good...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!