Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
The older I grow the more I distrust the familiar doctrine that age
brings wisdom.
-- H. L. Mencken
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Saturday, October 11, 2008
from the Forum department...
Mark 6, servo valve calibration
Topic: Engineering and workplace issues.
Originally posted by AmAm on 9 October, 2008 - 5:33 am
Mark 6 servo valve calibration.
New Replies:
By amam on 11 October, 2008 - 11:52 pm -
CSA, Thanks a lot. Your usual co-operation is highly appreciated....
By CSA on 11 October, 2008 - 11:35 am -
This topic has been covered several times in various threads on control.com. Two good posts on the...
from the Automation List department...
How to configure USB port in Visual Basic
Topic: Programming languages.
Originally posted by venkat on 15 October, 2005 - 3:32 pm
How can I configure USB port in VB
New Replies:
By Ravi on 11 October, 2008 - 8:22 pm -
I had similar requirement and the following is what I did: a) downloaded a VIRTUAL SERIAL PORT...
from the Mechanical/Electrical department...
Motor/Drive for Radio Dish
Topic: Engineering and workplace issues.
Originally posted by Mohammed Ahmed on 9 October, 2008 - 11:58 am
Need help with choosing a motor/drive system appropriate for operating a radio dish for amateur radio astronomy.
New Replies:
By William Gentry on 11 October, 2008 - 5:47 pm -
You potentially have more than one problem here. 1) The one you've asked about - use of a very...
By Ryan Butler on 11 October, 2008 - 4:43 pm -
Hi, You may want to consider using an analog (sine/cosine) encoder; these devices can allow...
By M Griffin on 11 October, 2008 - 1:34 pm -
I see two problems. First your requirements are for a 600 to 1 speed range (0.1 arcmin/sec to 60...
from the Forum department...
ControlLogix vs Quantum PLCs
Topic: PLCs and related questions.
Originally posted by Ryno83 on 29 September, 2008 - 10:58 pm
Pros and cons between ControlLogix and Quantum
New Replies:
By Bob Peterson on 11 October, 2008 - 5:35 pm -
I got to tell you. With the introduction of version 16 of Contrologix, I see no PLC platform that...
By Dave Zimbrich on 11 October, 2008 - 4:54 pm -
James, I must take issue with this statement: "No, I don't work for Rockwell Automation....
Topic: Communications systems and equipment.
Originally posted by Ajith on 1 April, 2008 - 11:13 pm
While communicating with slaves using Modbus master I am getting the following errors...
New Replies:
By Waqqas Ahmad on 11 October, 2008 - 3:32 pm -
I have also the sma error but it the CP341 does not receive any data. I think there is some...
from the control & Inst. department...
pressure gauge for high temperature
Topic: Sensor technologies.
Posted by engineer on 11 October, 2008 - 12:31 pm
what provision is for pressure measurement by gauge on 500 degree C temperature?
from the PLC Conversion department...
How to convert PLC-2 to PLC-5 fast?
Topic: PLCs and related questions.
Originally posted by Me on 8 October, 2008 - 3:46 pm
Convert Allen Bradley PLC-2 to PLC-5. Software needed? not available... :(
New Replies:
By Michael Batchelor on 11 October, 2008 - 12:16 pm -
I'll stand by my original comment. The guy who kept it on the PLC2 platform this long should be...
By Dave Ferguson on 11 October, 2008 - 10:53 am -
Do you have SPARE plc-5's when this one fails. I understand the no money thing and doing things on...
By Bob Peterson on 11 October, 2008 - 10:20 am -
We own a license for the AB software to convert PLC2 to PLC5. Having used it a few times, I can...
By Jeremy Pollard on 11 October, 2008 - 9:53 am -
I have some software that you can use as long as you respect the license agreement etc. How can I...
from the Over Engineering Dept department...
PID Loop VS. Siemens EA2 RTD Module
Topic: PLCs and related questions.
Posted by Mark Davis on 11 October, 2008 - 11:49 am
Why sacrifice closed loop control over process heat
from the Automation List department...
Communication problem between a PC and a SLC 5/03
Topic: PLCs and related questions.
Originally posted by Adekunle on 27 August, 2008 - 10:04 pm
cannot establish communication between a PC connected and PLC linked through a RS232 port after downloading the program.
New Replies:
By Trevor Ousey on 11 October, 2008 - 8:31 am -
Hi Adekunle, Sorry, I forgot to mention that RSLinx needs to be running as an application. If you...
from the Electrical department...
Nuisance tripping of RCCB
Topic: Engineering and workplace issues.
Originally posted by Shahvir on 10 October, 2008 - 11:41 pm
Occasional nuisance tripping of RCCB
New Replies:
By Phil Corso on 11 October, 2008 - 8:26 am -
Shahvir, how about providing details: 1) What is meant by 'some'? 2) Manufacturer? 3) Voltage ...
from the ENGG department...
Modbus RS-485 RTU communication cable
Topic: Communications systems and equipment.
Posted by Arjun on 11 October, 2008 - 7:55 am
I need the information/specification of of Modbus Rs-485 RTU communication cable for communication a PLC & DCS system.
from the Automation List department...
Replacement for MK V IDOS computer
Topic: Continuous process industries, DCS questions.
Originally posted by Sandy on 17 September, 2008 - 2:22 am
Mk V System Upgrade
New Replies:
By DAMENE Amar on 11 October, 2008 - 6:21 am -
Hi, Sandy It is a surprise that actually I am looking at possible replacements for 4 old Texas...
Topic: PLCs and related questions.
Posted by shabuddin on 11 October, 2008 - 4:59 am
Anybody can help me to do Mitsubishi PLC A series to Q series Transition.
from the I&C department...
SPPA-T1000
Topic: Engineering and workplace issues.
Originally posted by gasjobs on 9 November, 2007 - 10:31 pm
working of SPPA-T1000
New Replies:
By Sanjeev on 11 October, 2008 - 4:36 am -
Dear Sir I have the practical experience, it fails like a Simple PC, I can you atleast five...
By J Raj on 11 October, 2008 - 2:51 am -
We are using three Siemens T1000 system, i would say if you want to commit sucide then buy these...
from the Automation and Instrumentation department...
Water Treatment Process Control and Instrumentation
Topic: Continuous process industries, DCS questions.
Originally posted by Jan Michael Albaran on 8 October, 2008 - 7:39 pm
Best/better approach for the water treatment instrumentation and automation...
New Replies:
By wboyes on 11 October, 2008 - 1:01 am -
Well, yes and no. Because the field of a magnetic flowmeter extends from pipe wall to pipe wall,...
from the Forum department...
Load cell millivolt signal conditioner
Topic: Sensor technologies.
Originally posted by Simple68 on 25 September, 2008 - 3:20 am
Millivolt conversion from load cells
New Replies:
By S.Gordon on 11 October, 2008 - 12:53 am -
How could you be connecting MV signal directly to the PLC card?? You need a conditioner &...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!