Tuesday, October 14, 2008
from the control & instrument department...
Capillary for pressure gauge in high temp. service
Topic: Software, including programming, OS issues, etc.
Originally posted by engineer on 14 October, 2008 - 3:55 am
Utilisation of capillary for pressure gauge in high temp. service
New Replies:
By Roy Matson on 14 October, 2008 - 10:48 pm -
If by capillary type you mean remote diaphragm seal, I would say NO, the temperature is too high....
from the Forum department...
Load cell millivolt signal conditioner
Topic: Sensor technologies.
Originally posted by Simple68 on 25 September, 2008 - 3:20 am
Millivolt conversion from load cells
New Replies:
By Roy Matson on 14 October, 2008 - 10:35 pm -
S Gordon, There is no reason why you cannot connect the load cell to the PLC provided there is...
By Dave Zimbrich on 14 October, 2008 - 12:17 pm -
You might want to check out the KL3356 from Beckhoff Automation: ...
from the Forum department...
Suggestion of PLC, please!
Topic: PLCs and related questions.
Originally posted by aiks07 on 8 October, 2008 - 11:59 pm
Need suggestions!
New Replies:
By Jan Michael Albaran on 14 October, 2008 - 9:01 pm -
For me... you can really use different PLC... As a Siemens user before, it's really easy to use...
from the Forum department...
MK 6 event log
Topic: Human-Machine Interface and SCADA.
Originally posted by Giovanni on 12 October, 2008 - 10:20 pm
The MK6 Event log accessible from the localhost in internet explorer trigger each event twice.
New Replies:
By MIKEVI on 14 October, 2008 - 9:00 pm -
Giovanni, I can't say that I have seen this before on any of our machines. Have you done any...
from the Electrical Design department...
What makes an electrical schematic a standard one?
Topic: Engineering and workplace issues.
Originally posted by senthil on 4 October, 2008 - 12:52 pm
What makes an electrical schematic a standard one?
New Replies:
By M Griffin on 14 October, 2008 - 8:18 pm -
If this is to meet a customer specification, then I would suggest asking the customer for a sample...
By senthil on 14 October, 2008 - 12:10 pm -
Hi James, Thank you very much for your reply. UK follows IEC... Can you please tell me what...
from the Technology department...
Sensors with Modbus/TCP
Topic: Sensor technologies.
Originally posted by Emin Ceyhan on 14 October, 2008 - 1:54 am
I need a sensor with Modbus/TCP protocol support.
New Replies:
By M Griffin on 14 October, 2008 - 7:53 pm -
There are lots of "sensors" that work with Modbus/TCP. Unfortunately, you are a bit vague...
from the Forum department...
Simatic-555 Controller memory mapping
Topic: PLCs and related questions.
Posted by engelndmj on 14 October, 2008 - 7:26 pm
How do I relate the WY* address of Simatic 555, to Vf* address
Topic: Motion control, servos, steppers, etc.
Originally posted by Hadé on 12 October, 2008 - 12:11 pm
I would like to control the discharge of a flywheel using current mode control.
New Replies:
By Hadé on 14 October, 2008 - 5:11 pm -
Ok, but I am not really sure of how I should go about. I would want to use the PIC in order to...
By Robert Scott on 14 October, 2008 - 8:08 am -
If you consider the flywheel output as a discharging battery, then the problem is the same as with...
By Roy Matson on 14 October, 2008 - 6:09 am -
As Robert Scott says, the output voltage will drop with speed because the field is fixed. Does your...
Topic: Software, including programming, OS issues, etc.
Posted by Nicholas on 14 October, 2008 - 4:00 pm
I am trying to find out if it is even possible to use a standard flatbed image scanner to scan bar codes.
Topic: PLCs and related questions.
Posted by Robert Mehlman on 14 October, 2008 - 3:48 pm
Unity help file: DANGER, UNEXPECTED OUTPUT BEHAVIOUR
Topic: PLCs and related questions.
Originally posted by shabuddin on 11 October, 2008 - 4:59 am
Anybody can help me to do Mitsubishi PLC A series to Q series Transition.
New Replies:
By Ken Emmons Jr. on 14 October, 2008 - 3:47 pm -
I would just add if you can afford the more expensive Q02 or Q02H CPU you can get USB programming...
By hattedone on 14 October, 2008 - 5:00 am -
Can you confirm the part number AG61? I do not recognise that part (AG60 or AG62 are slot...
from the Dead zone? department...
Delta V Process Zones
Topic: Continuous process industries, DCS questions.
Posted by Ed Elliott on 14 October, 2008 - 3:36 pm
Does anyone have experience implementing Delta V's new functionality of Process Zones?
from the New to this department...
Connecting RS485 and RS422
Topic: Human-Machine Interface and SCADA.
Posted by John Elliott on 14 October, 2008 - 1:49 pm
Wondering how to connect PLC using RS485 and HMI using RS422 so that I can have them talk to each other over Modbus.
from the Automation List department...
Redundant AC800M
Topic: Engineering and workplace issues.
Originally posted by Mik on 7 August, 2008 - 12:16 am
Redundancy feature of AC800M controller from ABB
New Replies:
By PVRN on 14 October, 2008 - 1:32 pm -
Sorry, but I also hate to say that truth is bitter. AC800M has major problems with redundancy. It...
from the Automation department...
Electric Arc Furnace
Topic: Continuous process industries, DCS questions.
Originally posted by T. K GHOSH on 14 October, 2006 - 11:14 pm
Is it possible to install digital control regulation system with water hydraulics?
New Replies:
By Jivraj Sutaria on 14 October, 2008 - 9:26 am -
Dear Mr. Ghosh, You may contact us for your requirements on revamp of arc furnaces. Jivraj...
from the Electrical Communication department...
Spacing for Addressable Heat Detectors
Topic: Engineering and workplace issues.
Posted by Muhammad Zakria on 14 October, 2008 - 8:46 am
The question is the spacing requirement for the installation of addressable heat detectors of a specific make/model for storage shade.
from the Serious department...
Data Historian Upgrade
Topic: Information resources, documentation.
Posted by Duto on 14 October, 2008 - 7:07 am
We plan to upgrade our old UNIX based data historian. 3 packages are in the picture now: OSI PI, Aspen IP21 and Yokogawa Exaquantum. All will be connected to Yokogawa and Honeywell DCS...
Topic: Programming languages.
Originally posted by G.Perkins on 18 June, 2002 - 4:19 pm
High Level Programe languages
New Replies:
By Umair Anwar on 14 October, 2008 - 6:55 am -
Hi, Low level languages are: 1 - Machine Language 2 - Assembly Language High level...
from the maintenance department...
calibration of weighing system
Topic: PLCs and related questions.
Originally posted by pk on 13 October, 2008 - 7:18 am
what should be the right proceedure of calibaration.
New Replies:
By Roy Matson on 14 October, 2008 - 6:47 am -
Yes, it's difficult to do a span calibration. I assume you have several large load cells supporting...
Topic: PLCs and related questions.
Originally posted by Mike Ellis on 13 October, 2008 - 5:11 am
Sinking 12volts via Output relay card.
New Replies:
By Roy Matson on 14 October, 2008 - 6:14 am -
As Bob Peterson says, a relay output module will work for you. Roy...
By Jason on 14 October, 2008 - 4:30 am -
I had purchased an A-B MicroLogix 1500 LRP-C series along with 3 expansion modules 1769-OW16,...
from the Forum department...
Power Management Project
Topic: Engineering and workplace issues.
Originally posted by Sandy Chapman on 7 October, 2008 - 8:19 pm
Power Management project
New Replies:
By V_Vendetta on 14 October, 2008 - 5:51 am -
Hi There, May I know where is your location?...
from the Forum department...
Modbus communication with PLC
Topic: Communications systems and equipment.
Posted by saritha on 14 October, 2008 - 4:46 am
I am working with at89c52 controller. I want to communicate with PLC using Modbus RTC protocol.
from the Forum department...
Profibus PA segments allowable in EEx ia
Topic: Application Questions and Problems
Originally posted by benjas on 10 October, 2008 - 2:01 am
Profibus PA segments allowable in EEx ia
New Replies:
By benjas on 14 October, 2008 - 3:05 am -
Thanks it was very helpful. I also found this formula on the Siemens hompage: ...
from the Forum department...
Modbus Communication
Topic: Communications systems and equipment.
Posted by Ajith on 14 October, 2008 - 2:28 am
Siemens CP341 RS485 using Modbus Master Protocol with 4 Slaves. Last five pieces of data are missing in all Slaves...
Topic: Continuous process industries, DCS questions.
Originally posted by Magister on 2 October, 2008 - 1:07 am
Need to produce high frequency pulse output signal on Yokogawa CS3000
New Replies:
By Magister on 14 October, 2008 - 1:51 am -
Nice solution, thanks. :) I've made this scheme and thought that it's unnecessary to add...
from the PE department...
Spindle speed slowing
Topic: Engineering and workplace issues.
Posted by Amir on 14 October, 2008 - 12:45 am
Spindle speed control setting
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.