Monday, October 27, 2008
from the Problemas department...
DeltaV OPC Mirror OPC Server for odbc
Topic: Continuous process industries, DCS questions.
Originally posted by Anonymous on 19 August, 2005 - 10:01 pm
DeltaV OPC Mirror OPC Server for odbc
New Replies:
By Tim Alosi on 27 October, 2008 - 11:54 pm -
If you need OPC HDA for GDA server, OPC Mirror will not work with it... OPC Mirror only supports DA....
from the Automation List department...
Foxboro DCS and HMI
Topic: Human-Machine Interface and SCADA.
Originally posted by Afshin on 25 July, 2007 - 10:53 pm
I have a DCS system of Foxboro that its HMI is very old. I want to upgrade this HMI without change...
New Replies:
By srinivas on 27 October, 2008 - 10:21 pm -
Dear Sudhakar, Hi. I am srinivas and I am new in this Foxboro I/A series DCS for combined cycle...
Topic: Engineering and workplace issues.
Originally posted by Anonymous on 31 March, 2007 - 11:44 am
designing a relativly cheap (under $100) circuit board that connects a stepper motor and 2 optical encoders to the computer...
New Replies:
By cnc002 on 27 October, 2008 - 9:19 pm -
Actually, both you and Robert are at least partially correct. Robert is correct that the parallel...
from the Forum department...
Tandem Potentiometer emulation?
Topic: PLCs and related questions.
Posted by Steve on 27 October, 2008 - 8:06 pm
I need some guidance on where and what to use to generate the signals desired.
from the Programming languages department...
Shell command in VB 6
Topic: Programming languages.
Originally posted by D on 28 April, 2004 - 11:00 pm
Help with the shell command in VB 6
New Replies:
By JR on 27 October, 2008 - 6:23 pm -
Opening a file with the program via shell is great, but is there any way of automatically printing...
from the Automation List department...
What makes a generator increase load
Topic: Engineering and workplace issues.
Originally posted by kumarash on 10 August, 2008 - 3:49 pm
What makes a generator coupled to a gas turbine increase load when load raise command is issued to Mark V
New Replies:
By Kushwaha_r_k on 27 October, 2008 - 4:12 pm -
It's true that more fuel to prime mover increases the torque, which increases the load angle in the...
from the Dire need of help department...
VBA RSView 32 7.40.0
Topic: Human-Machine Interface and SCADA.
Posted by Nizam Ahmad on 27 October, 2008 - 3:48 pm
Help with VBA script in RSView
Topic: Motion control, servos, steppers, etc.
Originally posted by Hadé on 12 October, 2008 - 12:11 pm
I would like to control the discharge of a flywheel using current mode control.
New Replies:
By Hadé on 27 October, 2008 - 3:01 pm -
Thanks Bob, In fact my motor inductance is 3.3mH from the manufacturer's data sheet. When...
from the Forum department...
Fuel Control Valve Failure
Topic: Power generation equipment control.
Originally posted by datsacorn2511 on 24 October, 2008 - 1:45 am
There was failure in our control valve. Then the drum pressure increased. Why?
New Replies:
By Arnold Dillon on 27 October, 2008 - 12:53 pm -
It's hard to know why the fuel valve went to 100%. Normally, a load-following boiler is controlled...
from the c++ code for linux department...
Simple C or C++ script to read serial port buffer
Topic: Open interfaces, software and hardware
Originally posted by Obscurius on 27 August, 2004 - 1:31 am
I would like to read a text string from a device which connected to the serial port and save this string to a text file or in to a database..
New Replies:
By James Ingraham on 27 October, 2008 - 12:45 pm -
cww: "Of course, there's also the problem of having to have Windows on a machine. I suppose...
from the Electrical department...
Nuisance tripping of RCCB
Topic: Engineering and workplace issues.
Originally posted by Shahvir on 10 October, 2008 - 11:41 pm
Occasional nuisance tripping of RCCB
New Replies:
By shahvir on 27 October, 2008 - 12:33 pm -
Dear Rasam, How do you define a bad RCCB? Could you please list factors contributing to a bad...
from the howzitwork department...
Modbus Utility
Topic: Computers in manufacturing; also hardware discussion.
Originally posted by Ed Lee on 4 June, 2002 - 9:21 pm
I need a simple utility to run on my PC and communicate with a Modbus RTU slave...
New Replies:
By Brian on 27 October, 2008 - 11:19 am -
Any of the Modbus Master emulation programs mentioned should do what you require. My favorite can...
from the Serial Communication department...
Weigh Bridge reading
Topic: Application Questions and Problems
Originally posted by SKAKUM on 24 September, 2008 - 7:56 am
Problem in reading loadcell output through RS232
New Replies:
By Robert on 27 October, 2008 - 11:06 am -
That's the way I did it: Define 1 character that is ALWAYS in the string send by the bridge,...
from the Forum department...
PID loops and equations
Topic: Engineering and workplace issues.
Originally posted by Mike on 24 October, 2008 - 6:20 pm
PID coding
New Replies:
By George Buckbee on 27 October, 2008 - 10:42 am -
Your question highlights some very important points about signal filtering... There is an...
from the Instrumentation department...
Calibration of SMART Transmitters
Topic: Information resources, documentation.
Originally posted by Nandan Banerjee on 17 September, 2008 - 2:39 am
How to calibrate any SMART transmitters without using HART communicator?
New Replies:
By Jonas Berge on 27 October, 2008 - 10:38 am -
This video clip shows how EDDL wizards on software with interface (or handheld field communicator)...
from the Looking for ... department...
Modbus Slave Device
Topic: Communications systems and equipment.
Posted by Robert on 27 October, 2008 - 10:17 am
Modbus Slave Device
from the Forum department...
Hand/Finger motion detection
Topic: Sensor technologies.
Originally posted by Pete on 23 October, 2008 - 7:41 pm
What would be a practical method for detecting hand/finger motion?
New Replies:
By Pete on 27 October, 2008 - 10:12 am -
Thanks for the suggestions. I might end up using those mentioned flex sensors (if not also...
from the maintenance department...
ramp time in hydraulic system
Topic: Motion control, servos, steppers, etc.
Originally posted by pk on 26 October, 2008 - 3:20 pm
how can i decide the best ramp time?
New Replies:
By Robert Scott on 27 October, 2008 - 9:06 am -
About the only danger I can see in ramping down too fast is that the cylinder will lose contact...
from the Thermal Overload department...
PC based Control .vs. PLC
Topic: Computers in manufacturing; also hardware discussion.
Originally posted by Don Baechtel on 3 November, 1999 - 11:55 am
(Originally posted Tue, 25 Aug 1998) I am interested if anyone in the group has any specific reasons why they are still buying PLCs and not PC based controllers.
New Replies:
By Mark Forrester on 27 October, 2008 - 4:31 am -
To the one who is doing a school project on bearing wear: As a Navy veteran, we used DVSIs for...
from the Forum department...
PC (.NET) comm with A-B CompactLogix
Topic: Communications systems and equipment.
Posted by Jakob Kirkegaard on 27 October, 2008 - 4:16 am
.NET interface for simple digital I/O between PC and A-B CompactLogix series 1768 with 1768-ENBT Module.
from the None department...
Advant MB300 TCP/IP Interface
Topic: Software, including programming, OS issues, etc.
Originally posted by S P Coomar on 16 July, 2002 - 1:23 pm
Vendor or Software house for ABB Advant-MB300 interface.
New Replies:
By venki on 27 October, 2008 - 3:50 am -
Hi, We need more details. We are facing problem with Matricon OPC server. Please give your site...
from the Automation List department...
Slow communication between Citect SCADA and Quantum
Topic: Communications systems and equipment.
Originally posted by Chris on 27 June, 2008 - 12:23 am
Slow communication between Citect SCADA and Quantum results in long time SCADA's screens opening.
New Replies:
By Pablo on 27 October, 2008 - 3:13 am -
Description of application: -Configuration: 1. Local I/O Quantum Drop - 140 CPS 114 XO, 140 CPU...
from the Free Software department...
New Release of Open Source Web Based HMI
Topic: Open interfaces, software and hardware
Posted by M Griffin on 27 October, 2008 - 2:30 am
New release of open source Web Based HMI.
from the Technical Office of Power Plant department...
ABB Infi 90 DCS system
Topic: Continuous process industries, DCS questions.
Posted by sameipoor on 27 October, 2008 - 1:40 am
Graphic design of PCV software
from the Instrument department...
EExd smoke detector
Topic: Application Questions and Problems
Originally posted by pc on 24 October, 2008 - 7:22 am
EExd smoke detector
New Replies:
By Node17 on 27 October, 2008 - 12:00 am -
F2000 EExd Flameproof Infrared Optical Beam Smoke Detector by Fire Fighting Enterprises Ltd. ATEX...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!