Wednesday, October 29, 2008We have a GE MS5001 machine with Speedtronic MarkV control system supplied by Thomesson. Six hydrocarbon leak detectors (weather housing type: 00780-A-0076, Sieger, Ltd. England). We require specifications for these sensors.
New Replies:
By CSA on 29 October, 2008 - 11:27 pm -
By CSA on 29 October, 2008 - 11:27 pm -
What happened when you did a Google search for "Sieger gas detector"?...
Mark V HMI upgrade possibility?
New Replies:
By CSA on 29 October, 2008 - 11:23 pm -
By CSA on 29 October, 2008 - 11:23 pm -
I don't believe GE is manufacturing Mark V control systems these days.
...
By ainuddin on 29 October, 2008 - 8:19 am - Arcnet card will still be there since that's the communication used in Mark V.
Next year we'll...
I have a PLC Twido TWDLMDA20DTK, and I design a HMI with MyTek PV084 TNT. Need addresses in Modbus for MyTek.
New Replies:
By MikeD on 29 October, 2008 - 9:21 pm -
By MikeD on 29 October, 2008 - 9:21 pm -
I can't help you with the MYTek HMI, but the Twido will respond to Modbus commands, and do the...
I need some guidance on where and what to use to generate the signals desired.
New Replies:
By Steve on 29 October, 2008 - 9:16 pm -
By Steve on 29 October, 2008 - 9:16 pm -
Thank you gents,
Could you show me an example of an A/D device that could do this?
Thanks,
...
I am new to Honeywell DCS product. Would like to know the basic information of Experion PKS system.
New Replies:
By M. Perez on 29 October, 2008 - 8:47 pm -
By M. Perez on 29 October, 2008 - 8:47 pm -
Honeywell usually requires you to fill out a subscription form first before releasing the product...
Can anyone suggest an alternate FSK Modem?
New Replies:
By Mike Lamond on 29 October, 2008 - 6:59 pm -
By Mike Lamond on 29 October, 2008 - 6:59 pm -
From those specs, I think the old RTUs have Bell 202T leased-line telemetry modems. I've used these...
By Jerry Miille on 29 October, 2008 - 12:34 pm - The MARC 366-101 matches most of the specifications you list. The major differences are that we...
Difference between two ISA, interface cards
I would like to read a text string from a device which connected to the serial port and save this string to a text file or in to a database..
New Replies:
By James Ingraham on 29 October, 2008 - 5:53 pm -
By James Ingraham on 29 October, 2008 - 5:53 pm -
As a follow up, here's some info from the Visual Studio Express FAQ at
...
By James Ingraham on 29 October, 2008 - 2:48 pm - M Griffin: "I believe Microsoft's developer tools division is profitable."
It's hard...
By Curt Wuollet on 29 October, 2008 - 1:24 am - Actually, a one day event (and extreme boredom with the whole proprietary meadow muffin) has...
Can a 3 phase DC brushless motor be controlled under a 3 phase AC controller?
New Replies:
By Ahmed Rehan on 29 October, 2008 - 4:15 pm -
By Ahmed Rehan on 29 October, 2008 - 4:15 pm -
The difference between 3 phase AC controller and DC controller is that 3 phase AC uses sine wave...
.NET interface for simple digital I/O between PC and A-B CompactLogix series 1768 with 1768-ENBT Module.
New Replies:
By Mark on 29 October, 2008 - 3:57 pm -
By Mark on 29 October, 2008 - 3:57 pm -
Hi Jakob,
Automated Solutions .NET driver for Logix family is available with two license...
All the Vendors claim their offering is a true DCS and 'can perform the assigned role'...
New Replies:
By B90 on 29 October, 2008 - 3:21 pm -
By B90 on 29 October, 2008 - 3:21 pm -
My experience is with ABB legacy system and I am new to PCS7. My first reaction was that this was...
How do I run one application of RSView32 with two monitors?
New Replies:
By KC_Bob on 29 October, 2008 - 3:11 pm -
By KC_Bob on 29 October, 2008 - 3:11 pm -
We have the same situation, and here is the best solution I have come up with.
1) Start RSView,...
Can anyone recommend to me a Radio Modem, i.e. a modem that converts serial data to modulated PTT enabled data?
New Replies:
By Bill Schwarz on 29 October, 2008 - 2:02 pm -
By Bill Schwarz on 29 October, 2008 - 2:02 pm -
Try this site:
http://www.calamp.com/calamp_3_monitorcontent/monitoring_control.html...
Machine DATA
New Replies:
By ryeatman on 29 October, 2008 - 1:01 pm -
By ryeatman on 29 October, 2008 - 1:01 pm -
I am in desperate need for an 'AXIS Card' for my BOSCH CC 100 controller. Not sure which of the...
Which topology is best?
New Replies:
By Paul Wacker on 29 October, 2008 - 12:52 pm -
By Paul Wacker on 29 October, 2008 - 12:52 pm -
Ring topology Ethernet networks are not necessarily proprietary. It is possible to implement them...
Best portable flow sensors available.
Advantages of Mark VI and Mark V over Mark IV?
New Replies:
By CSA on 29 October, 2008 - 9:35 am -
By CSA on 29 October, 2008 - 9:35 am -
This is a very commonly repeated "falsehood". GE did NOT purchase Woodward Governor Co....
from the Forum department...
Least count of flame detector in GE FRAME 9E gas turbine MARK V control systemCertain logics are becoming 1 when the FD reaches some specific counts defined by GE...
New Replies:
By CSA on 29 October, 2008 - 9:28 am -
By CSA on 29 October, 2008 - 9:28 am -
Have you read Section. 7.8 of the the Mark V Application Manual, GEH-6195?...
By martinc on 29 October, 2008 - 9:24 am - To ascertain the threshold of your flame detector logic, you need to check Screen 3/5 of TCEA...
By 4_20ma on 29 October, 2008 - 12:03 am - Please very it whether it is less than 16 or greater than 16. I don't think less than 16 is correct....
Communication between Siemens S7 400 PLC and ABB AC800 PLC
Modbus Plus interface card options
Tests for 15000 KVA Alternator, Siemens make, 6 KV.
To measure loop resistance of small motors rated in KVA, we simply use a multimeter to get required results. Why doesn't multimeter work there?
Modbus library for NI Measurement Studio?
I don't find the function to read the information of the PM710
For onshore plant optimization there's a software for data reconciliation. Now it starts to move offshore.
New release of open source Web Based HMI.
New Replies:
By Tallak Tveide on 29 October, 2008 - 3:38 am -
By Tallak Tveide on 29 October, 2008 - 3:38 am -
Hi!
I have been working on something similar based on ruby on rails. Your work is very...
By M Griffin on 29 October, 2008 - 3:17 am - With regards to how IE handles SVG, the answer is a bit more complicated. There are two ways of...
Problems with Lamp test.
New Replies:
By yantsi on 29 October, 2008 - 2:56 am -
By yantsi on 29 October, 2008 - 2:56 am -
Communicate using RS485 protocol or others?...
Would u suggest any institution for embedded systems in hyderabad?
New Replies:
By srinivas on 29 October, 2008 - 2:45 am -
By srinivas on 29 October, 2008 - 2:45 am -
No doubt veda has such a good instructor, but believe me course will drag like anything. Too many...
Convert single phase to 3 phase for battery charger.
I need a comparison between Modbus and IEC 101
New Replies:
By young won on 29 October, 2008 - 12:25 am -
By young won on 29 October, 2008 - 12:25 am -
Please send me also the information at 'ywshim at hec. co. kr'....
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.