from the Instrumentation & Control department...
Hydrocarbon Leak Detector for GE MS5001 Machine
Topic: Continuous process industries, DCS questions.
Originally posted by Virendra Kiran on 29 October, 2008 - 1:37 am
We have a GE MS5001 machine with Speedtronic MarkV control system supplied by Thomesson. Six hydrocarbon leak detectors (weather housing type: 00780-A-0076, Sieger, Ltd. England). We require specifications for these sensors.
New Replies:
By CSA on 29 October, 2008 - 11:27 pm -
What happened when you did a Google search for "Sieger gas detector"?...
from the Mark V department...
Mark V HMI Upgrade
Topic: Human-Machine Interface and SCADA.
Originally posted by dinster on 18 September, 2008 - 1:34 am
Mark V HMI upgrade possibility?
New Replies:
By CSA on 29 October, 2008 - 11:23 pm -
I don't believe GE is manufacturing Mark V control systems these days. ...
By ainuddin on 29 October, 2008 - 8:19 am -
Arcnet card will still be there since that's the communication used in Mark V. Next year we'll...
from the Forum department...
MYTek HMI and Twido help
Topic: PLCs and related questions.
Originally posted by youds on 22 October, 2008 - 5:50 am
I have a PLC Twido TWDLMDA20DTK, and I design a HMI with MyTek PV084 TNT. Need addresses in Modbus for MyTek.
New Replies:
By MikeD on 29 October, 2008 - 9:21 pm -
I can't help you with the MYTek HMI, but the Twido will respond to Modbus commands, and do the...
from the Forum department...
Tandem Potentiometer emulation?
Topic: PLCs and related questions.
Originally posted by Steve on 27 October, 2008 - 8:06 pm
I need some guidance on where and what to use to generate the signals desired.
New Replies:
By Steve on 29 October, 2008 - 9:16 pm -
Thank you gents, Could you show me an example of an A/D device that could do this? Thanks, ...
from the Inst & Controls department...
Basic Information on Experion PKS
Topic: Software, including programming, OS issues, etc.
Originally posted by Krish on 28 October, 2008 - 9:08 pm
I am new to Honeywell DCS product. Would like to know the basic information of Experion PKS system.
New Replies:
By M. Perez on 29 October, 2008 - 8:47 pm -
Honeywell usually requires you to fill out a subscription form first before releasing the product...
from the Communications department...
Modem Equivalent
Topic: Communications systems and equipment.
Originally posted by Saad on 28 October, 2008 - 11:30 am
Can anyone suggest an alternate FSK Modem?
New Replies:
By Mike Lamond on 29 October, 2008 - 6:59 pm -
From those specs, I think the old RTUs have Bell 202T leased-line telemetry modems. I've used these...
By Jerry Miille on 29 October, 2008 - 12:34 pm -
The MARC 366-101 matches most of the specifications you list. The major differences are that we...
from the information department...
Modicon
Topic: Information resources, documentation.
Posted by donna on 29 October, 2008 - 6:25 pm
Difference between two ISA, interface cards
from the c++ code for linux department...
Simple C or C++ script to read serial port buffer
Topic: Open interfaces, software and hardware
Originally posted by Obscurius on 27 August, 2004 - 1:31 am
I would like to read a text string from a device which connected to the serial port and save this string to a text file or in to a database..
New Replies:
By James Ingraham on 29 October, 2008 - 5:53 pm -
As a follow up, here's some info from the Visual Studio Express FAQ at ...
By James Ingraham on 29 October, 2008 - 2:48 pm -
M Griffin: "I believe Microsoft's developer tools division is profitable." It's hard...
By Curt Wuollet on 29 October, 2008 - 1:24 am -
Actually, a one day event (and extreme boredom with the whole proprietary meadow muffin) has...
from the and 3 phase AC department...
3 phase DC motor for car
Topic: Motion control, servos, steppers, etc.
Originally posted by Yves on 14 January, 2005 - 9:28 am
Can a 3 phase DC brushless motor be controlled under a 3 phase AC controller?
New Replies:
By Ahmed Rehan on 29 October, 2008 - 4:15 pm -
The difference between 3 phase AC controller and DC controller is that 3 phase AC uses sine wave...
from the Forum department...
PC (.NET) comm with A-B CompactLogix
Topic: Communications systems and equipment.
Originally posted by Jakob Kirkegaard on 27 October, 2008 - 4:16 am
.NET interface for simple digital I/O between PC and A-B CompactLogix series 1768 with 1768-ENBT Module.
New Replies:
By Mark on 29 October, 2008 - 3:57 pm -
Hi Jakob, Automated Solutions .NET driver for Logix family is available with two license...
from the Automation List department...
Can Siemens PCS7 be considered as a True DCS?
Topic: Application Questions and Problems
Originally posted by Dr. R. Murugesan on 24 March, 2007 - 10:17 am
All the Vendors claim their offering is a true DCS and 'can perform the assigned role'...
New Replies:
By B90 on 29 October, 2008 - 3:21 pm -
My experience is with ABB legacy system and I am new to PCS7. My first reaction was that this was...
from the ROCKWELL department...
RSView32 Dual Monitors
Topic: Human-Machine Interface and SCADA.
Originally posted by MalibuSteve on 30 August, 2008 - 6:24 pm
How do I run one application of RSView32 with two monitors?
New Replies:
By KC_Bob on 29 October, 2008 - 3:11 pm -
We have the same situation, and here is the best solution I have come up with. 1) Start RSView,...
from the Radio Modems department...
Radio Communication
Topic: Communications systems and equipment.
Originally posted by Saad on 28 October, 2008 - 10:05 am
Can anyone recommend to me a Radio Modem, i.e. a modem that converts serial data to modulated PTT enabled data?
New Replies:
By Bill Schwarz on 29 October, 2008 - 2:02 pm -
Try this site: http://www.calamp.com/calamp_3_monitorcontent/monitoring_control.html...
from the Automation List department...
BOSCH CC100
Topic: Motion control, servos, steppers, etc.
Originally posted by Anonymous on 21 May, 2004 - 5:47 pm
Machine DATA
New Replies:
By ryeatman on 29 October, 2008 - 1:01 pm -
I am in desperate need for an 'AXIS Card' for my BOSCH CC 100 controller. Not sure which of the...
from the For Automation department...
Ethernet topology
Topic: Local and wide area networking in factory automation.
Originally posted by vinay on 22 October, 2008 - 11:05 pm
Which topology is best?
New Replies:
By Paul Wacker on 29 October, 2008 - 12:52 pm -
Ring topology Ethernet networks are not necessarily proprietary. It is possible to implement them...
from the Ultrasonic surface mount flow sensors department...
Portable Flow Sensors
Topic: Sensor technologies.
Posted by Sam Hardin on 29 October, 2008 - 10:01 am
Best portable flow sensors available.
Topic: Power generation equipment control.
Originally posted by James on 2 October, 2008 - 1:03 am
Advantages of Mark VI and Mark V over Mark IV?
New Replies:
By CSA on 29 October, 2008 - 9:35 am -
This is a very commonly repeated "falsehood". GE did NOT purchase Woodward Governor Co....
Topic: Power generation equipment control.
Originally posted by 4_20ma on 24 October, 2008 - 11:51 pm
Certain logics are becoming 1 when the FD reaches some specific counts defined by GE...
New Replies:
By CSA on 29 October, 2008 - 9:28 am -
Have you read Section. 7.8 of the the Mark V Application Manual, GEH-6195?...
By martinc on 29 October, 2008 - 9:24 am -
To ascertain the threshold of your flame detector logic, you need to check Screen 3/5 of TCEA...
By 4_20ma on 29 October, 2008 - 12:03 am -
Please very it whether it is less than 16 or greater than 16. I don't think less than 16 is correct....
Topic: PLCs and related questions.
Posted by Asim Shahzad on 29 October, 2008 - 8:53 am
Communication between Siemens S7 400 PLC and ABB AC800 PLC
from the modbus plus department...
Modbus Plus interface cards
Topic: Human-Machine Interface and SCADA.
Posted by av on 29 October, 2008 - 8:40 am
Modbus Plus interface card options
from the Electrical department...
Alternator
Topic: Engineering and workplace issues.
Posted by Hussain Ali on 29 October, 2008 - 7:25 am
Tests for 15000 KVA Alternator, Siemens make, 6 KV.
Topic: Engineering and workplace issues.
Posted by sunny on 29 October, 2008 - 7:24 am
To measure loop resistance of small motors rated in KVA, we simply use a multimeter to get required results. Why doesn't multimeter work there?
from the Forum department...
Modbus library for NI Measurement Studio?
Topic: Information resources, documentation.
Posted by zesk on 29 October, 2008 - 7:00 am
Modbus library for NI Measurement Studio?
from the Forum department...
Read PM710 with Modicon M340
Topic: Programming languages.
Posted by OMI on 29 October, 2008 - 6:10 am
I don't find the function to read the information of the PM710
from the Instrument department...
Data Reconciliation
Topic: Software, including programming, OS issues, etc.
Posted by Syukri on 29 October, 2008 - 5:12 am
For onshore plant optimization there's a software for data reconciliation. Now it starts to move offshore.
from the Free Software department...
New Release of Open Source Web Based HMI
Topic: Open interfaces, software and hardware
Originally posted by M Griffin on 27 October, 2008 - 2:30 am
New release of open source Web Based HMI.
New Replies:
By Tallak Tveide on 29 October, 2008 - 3:38 am -
Hi! I have been working on something similar based on ruby on rails. Your work is very...
By M Griffin on 29 October, 2008 - 3:17 am -
With regards to how IE handles SVG, the answer is a bit more complicated. There are two ways of...
from the Forum department...
Delta V and AN-6100C Annunciator
Topic: Engineering and workplace issues.
Originally posted by Mike on 20 October, 2008 - 7:15 am
Problems with Lamp test.
New Replies:
By yantsi on 29 October, 2008 - 2:56 am -
Communicate using RS485 protocol or others?...
from the Automation List department...
Embedded systems in Hyderabad
Topic: Information resources, documentation.
Originally posted by suresh on 30 June, 2006 - 10:17 pm
Would u suggest any institution for embedded systems in hyderabad?
New Replies:
By srinivas on 29 October, 2008 - 2:45 am -
No doubt veda has such a good instructor, but believe me course will drag like anything. Too many...
Topic: Power generation equipment control.
Posted by DIPNDAP on 29 October, 2008 - 1:25 am
Convert single phase to 3 phase for battery charger.
from the Automation List department...
Comparison between Modbus and IEC 60870-5-101
Topic: Local and wide area networking in factory automation.
Originally posted by adnane on 23 April, 2008 - 11:05 pm
I need a comparison between Modbus and IEC 101
New Replies:
By young won on 29 October, 2008 - 12:25 am -
Please send me also the information at 'ywshim at hec. co. kr'....
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!