Member Login
Search
Jump to a Date
Sponsored Communities
Cool stuff
Neat Stuff

Visit our shop for nerds in control lifestyle products.
Thermal Overload
The threads that wouldn't die...
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
Fortune
A triangle which has an angle of 135 degrees is called an obscene
triangle.
triangle.
RSS Feed
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Posts from...
Thursday, October 30, 2008Step by step for GE Frame 9 overspeed test.
New Replies:
By CSA on 30 October, 2008 - 10:25 pm -
By CSA on 30 October, 2008 - 10:25 pm -
Yes; lots of people here have experience with Frame 9E overspeed testing.
What is your specific...
We have a GE MS5001 machine with Speedtronic MarkV control system supplied by Thomesson. Six hydrocarbon leak detectors (weather housing type: 00780-A-0076, Sieger, Ltd. England). We require specifications for these sensors.
New Replies:
By CSA on 30 October, 2008 - 10:17 pm -
By CSA on 30 October, 2008 - 10:17 pm -
It's very common for companies to buy each other and retain the assimilated company's product line...
By gvkiran on 30 October, 2008 - 1:20 am - i had already searched in Google about SIEGER LEAK DETECTORS but I could not find any...
Modbus Plus interface card options
New Replies:
By Robert Willis on 30 October, 2008 - 7:06 pm -
By Robert Willis on 30 October, 2008 - 7:06 pm -
Schndier Electreic offers the following Modbus Plus Interfaces.
416NHM21234 PCMCIA Type 3...
By Roy Matson on 30 October, 2008 - 4:20 pm - Years ago we used the SA85 card, I'm sure there are other options nowadays. If you search...
Difference between two ISA, interface cards
New Replies:
By Robert Willis on 30 October, 2008 - 6:55 pm -
By Robert Willis on 30 October, 2008 - 6:55 pm -
The Modbus Plus ISA-SA85 adapter (AM-SA85-000) has been replaced with the (AM-SA85-030). This is...
Having an EZ Automation PLC open a TCP socket
Level Instrumentation
PID coding
New Replies:
By Mike on 30 October, 2008 - 6:21 pm -
By Mike on 30 October, 2008 - 6:21 pm -
Hey Bruce,
Thanks for your reply. I am still a bit undecided about the integral. In my code...
To measure loop resistance of small motors rated in KVA, we simply use a multimeter to get required results. Why doesn't multimeter work there?
New Replies:
By Roy Matson on 30 October, 2008 - 4:14 pm -
By Roy Matson on 30 October, 2008 - 4:14 pm -
I will try to answer part 1.
The resistance of your large machine is very low so a multimeter's...
Convert single phase to 3 phase for battery charger.
New Replies:
By Robert D. Wagner on 30 October, 2008 - 2:18 pm -
By Robert D. Wagner on 30 October, 2008 - 2:18 pm -
Check out single to 3-phase converters at phase-a-matic.com, also available
from...
By Curt Wuollet on 30 October, 2008 - 1:28 am - I wouldn't bet on that. Even for a battery charger, a polyphase rectifier is designed for the...
New release of open source Web Based HMI.
New Replies:
By James Ingraham on 30 October, 2008 - 2:12 pm -
By James Ingraham on 30 October, 2008 - 2:12 pm -
"With regards to how IE handles SVG, the answer is a bit more complicated."
Wow. No...
By M Griffin on 30 October, 2008 - 1:16 pm - My implementation will be to add this as another protocol to the MBServer package. I don't run a...
By pv on 30 October, 2008 - 8:59 am - Here is another Open Source HMI/SCADA system.
http://pvbrowser.org
"pvbrowser is an...
By Curt Wuollet on 30 October, 2008 - 1:15 am - I wonder what happened to the Rockwell patent that purports to cover any use of a browser with PLC...
About the Modbus communication problem with ABB PLC 07 KT 97
New Replies:
By LS on 30 October, 2008 - 1:15 pm -
By LS on 30 October, 2008 - 1:15 pm -
I think you have to check ABB manuals because you have to follow some directions for setup same...
I would like to read a text string from a device which connected to the serial port and save this string to a text file or in to a database..
New Replies:
By M Griffin on 30 October, 2008 - 12:11 pm -
By M Griffin on 30 October, 2008 - 12:11 pm -
In reply to Curt Wuollet, be prepared for an endeavour to get anything working on WINE/Codeweavers...
How do I run one application of RSView32 with two monitors?
Program memory is getting erased automatically while rebooting the connected PC.
New Replies:
By ddb763 on 30 October, 2008 - 11:41 am -
By ddb763 on 30 October, 2008 - 11:41 am -
Check the PLC Memory Battery....
By Kiran on 30 October, 2008 - 5:58 am - The data you had posted is not so clear. I want to know whether the PLC is also getting rebooted...
Best portable flow sensors available.
New Replies:
By wboyes on 30 October, 2008 - 11:32 am -
By wboyes on 30 October, 2008 - 11:32 am -
Well, the problem is that "Flow Meter Charming" (the perfect flowmeter) isn't around...
Communication between Siemens S7 400 PLC and ABB AC800 PLC
New Replies:
By Shahid Waqas on 30 October, 2008 - 11:07 am -
By Shahid Waqas on 30 October, 2008 - 11:07 am -
There are many methods for the communication. The two most common methods would be:
1. Use serial...
Powermonitor 3000 Modbus comms
Trends causing app to "crash"
Need help to find NETLIB.LIB
Problem in reading loadcell output through RS232
New Replies:
By SKAKUM on 30 October, 2008 - 7:23 am -
By SKAKUM on 30 October, 2008 - 7:23 am -
Yes, exactly. The original data, for example the weight of the truck, is in between junk...
Can we use a DP transmitter to measure the water level in a vacuum tank? If not, what is the solution for it?
New Replies:
By ultima on 30 October, 2008 - 6:43 am -
By ultima on 30 October, 2008 - 6:43 am -
What process did you try to measured?
Is that a Boiler Feed Water or similar with sugar refinery...
I need a suggestion to build a DCS sort of like integrated control system with various PLCs.
I need some guidance on where and what to use to generate the signals desired.
New Replies:
By Curt Wuollet on 30 October, 2008 - 1:09 am -
By Curt Wuollet on 30 October, 2008 - 1:09 am -
Any PLC with an analog input and two analog outputs could be programmed to do this. You would...
I don't find the function to read the information of the PM710
New Replies:
By Robert Willis on 30 October, 2008 - 12:30 am -
By Robert Willis on 30 October, 2008 - 12:30 am -
Take a look at the READ_VAR and WRITE_VAR functions in Unity. In Unity Pro Version 4.0 there is an...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.
Our Advertisers
Help keep our servers running...
Patronize our advertisers!
Patronize our advertisers!













