Thermal Overload
The threads that wouldn't die...
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
Fortune
There are three ways to get something done: do it yourself, hire
someone, or forbid your kids to do it.
someone, or forbid your kids to do it.
RSS Feed
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Posts from...
Friday, October 31, 2008Level Instrumentation
New Replies:
By Roy Matson on 31 October, 2008 - 8:11 pm -
By Roy Matson on 31 October, 2008 - 8:11 pm -
No, there is no standard, it depends on the site.
If it's a critical application it might have...
By wboyes on 31 October, 2008 - 10:49 am - I don't believe that there is a standard, but it is good engineering practice if the level in the...
By Sourav on 31 October, 2008 - 5:40 am - Yes, it is required to install a level gauge with level transmitter. The level gauge is for local...
Does anyone have experience implementing Delta V's new functionality of Process Zones?
New Replies:
By pt on 31 October, 2008 - 6:31 pm -
By pt on 31 October, 2008 - 6:31 pm -
This feature is fairly new, released with the v9.3 release of DeltaV (late 2007/early 2008). I've...
Mark V HMI upgrade possibility?
New Replies:
By CSA on 31 October, 2008 - 5:37 pm -
By CSA on 31 October, 2008 - 5:37 pm -
I've looked at the Matrikon site, and I have a few questions about using MatrikonOPC Server to...
Powermonitor 3000 Modbus comms
New Replies:
By Jerry Miille on 31 October, 2008 - 12:38 pm -
By Jerry Miille on 31 October, 2008 - 12:38 pm -
This is not unusual. Since Modbus does not define a floating point data type there are all sorts of...
I need a suggestion to build a DCS sort of like integrated control system with various PLCs.
New Replies:
By wboyes on 31 October, 2008 - 10:47 am -
By wboyes on 31 October, 2008 - 10:47 am -
Here's my best definition of a DCS.
"A DCS is a system comprised of proprietary field...
I am facing problem while communicating Rockwell CN2DN with Schneider relay...
I need a sensor with Modbus/TCP protocol support.
New Replies:
By Don Lupo on 31 October, 2008 - 9:27 am -
By Don Lupo on 31 October, 2008 - 9:27 am -
Hello Emin,
If you're still looking for a solution(s), you might want to contact
Reva and...
from the Forum department...
Least count of flame detector in GE FRAME 9E gas turbine MARK V control systemCertain logics are becoming 1 when the FD reaches some specific counts defined by GE...
New Replies:
By 4_20ma on 31 October, 2008 - 7:38 am -
By 4_20ma on 31 October, 2008 - 7:38 am -
Thank you so much Mr. Martin.
I hope this but that first response was the logic such as L28FDS,...
Problem in reading loadcell output through RS232
New Replies:
By SKAKUM on 31 October, 2008 - 6:06 am -
By SKAKUM on 31 October, 2008 - 6:06 am -
If you can provide your mail id I'll send the screen shot of what I got on the hyperterminal.
...
By M Griffin on 31 October, 2008 - 12:28 am - I'm not sure if you are saying the reply was enough information for you or whether you are...
PID coding
New Replies:
By Bruce Durdle on 31 October, 2008 - 6:00 am -
By Bruce Durdle on 31 October, 2008 - 6:00 am -
Hi Mike,
No, you don't wait for the IAT and then add in the integral - in a large process, Ti...
What is maximum DST count that DeltaV MD+ Controller can handle at 70% load?
New release of open source Web Based HMI.
New Replies:
By M Griffin on 31 October, 2008 - 3:40 am -
By M Griffin on 31 October, 2008 - 3:40 am -
In reply to James Ingraham: I'm not 100% sure the plug-in won't work for this, I just have serious...
Modbus Plus interface card options
New Replies:
By Patrick Lansdorf on 31 October, 2008 - 3:25 am -
By Patrick Lansdorf on 31 October, 2008 - 3:25 am -
Hi there,
You could also use a gateway, maybe Modbus + to Modbus TCP and use Modscan or mod poll...
Resources for Yokogawa CS-3000 DCS programming and graphics standards
I would like to read a text string from a device which connected to the serial port and save this string to a text file or in to a database..
New Replies:
By Curt Wuollet on 31 October, 2008 - 12:39 am -
By Curt Wuollet on 31 October, 2008 - 12:39 am -
I played around a bit with their software and came away with the impression that their free...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.