Wednesday, November 5, 2008
from the Forum department...
Simatic-555 Controller memory mapping
Topic: PLCs and related questions.
Originally posted by engelndmj on 14 October, 2008 - 7:26 pm
How do I relate the WY* address of Simatic 555, to Vf* address
New Replies:
By Ronald on 5 November, 2008 - 9:59 pm -
A WY address is part of the image register and there is no other way to address the WY The Vf you...
from the Forum department...
What's wrong with my FactoryTalk system?
Topic: Human-Machine Interface and SCADA.
Posted by zhangjc on 5 November, 2008 - 9:31 pm
Client computer is disconnected from the FactoryTalk Directory server.
Topic: Power generation equipment control.
Originally posted by krchome on 4 November, 2008 - 6:24 pm
Gas Control Valve Calibration procedure (Mark IV & V)
New Replies:
By CSA on 5 November, 2008 - 6:37 pm -
Hello, The procedures for Mark IV and Mark V are similar, but different. Those for a Mark II are...
from the Forum department...
Modbus RTU over serial port
Topic: Local and wide area networking in factory automation.
Originally posted by vijay on 4 November, 2008 - 3:52 pm
Modbus
New Replies:
By Schneider Italy on 5 November, 2008 - 5:04 pm -
Yes it is. You may need to use a crossed 232 cable. One side pins 2-3-5 Other side 3-2-5...
from the electrical engineering department...
%impedence of power transformer
Topic: Engineering and workplace issues.
Originally posted by ramesh on 5 August, 2008 - 1:12 am
Elaborate on % impedence of power transformer.
New Replies:
By Phil Corso on 5 November, 2008 - 3:09 pm -
Responding to Points [2] & [3] in Narayanan's 03-Nov-08 (01:52) query: Typically a...
from the PLC/HMI Drivers department...
WinCC communication with Modicon Momentum PLC
Topic: Communications systems and equipment.
Originally posted by Shalin on 12 September, 2008 - 1:21 am
Siemens WinCC HMI package to communicate to a Modicon Momentum PLC using MODBUS interface
New Replies:
By AR on 5 November, 2008 - 2:04 pm -
Hi, I tried, but I have the same problem. If anybody finds a solution, please email to me:...
Topic: Communications systems and equipment.
Originally posted by Topak on 4 November, 2008 - 4:42 am
Plantstreamer 1.0 r2 software
New Replies:
By Andrey Romanenko on 5 November, 2008 - 2:03 pm -
Plantstreamer is our open source solution that can be used to log plant data in a PosgreSQL...
By Graham Burnikell on 5 November, 2008 - 7:52 am -
Hi Topak, What is the error message you get? Are you trying to connect on the same PC, different...
from the Forum department...
Motor Starter with Stuck Button Detection
Topic: Engineering and workplace issues.
Posted by Fluoronator on 5 November, 2008 - 11:08 am
Looking for a method to detect stuck start buttons to prevent unexpected motor start-up when controls are energized.
from the electrical department...
need visual basic modbus sample code
Topic: Communications systems and equipment.
Originally posted by sankey on 12 August, 2005 - 5:00 pm
i want to create an interface in VB that will send modbus comments to the twido plc.
New Replies:
By Pritam Sinha on 5 November, 2008 - 9:44 am -
I've seen that program but I want reads swapped long data type. How it is possible? Please advise. ...
from the Instrumentation department...
EDDL
Topic: Software, including programming, OS issues, etc.
Originally posted by stem_p1st on 28 October, 2008 - 3:04 am
How can Emerson Instrumentation Equipment be configured by PACTWare?
New Replies:
By Jonas Berge on 5 November, 2008 - 8:02 am -
Any system, software, or handheld communicator supporting EDDL can be used. Some of them are...
from the Forum department...
DeviceNet explicit message help!!
Topic: Local and wide area networking in factory automation.
Posted by Joseph Lee on 5 November, 2008 - 7:55 am
DeviceNet explicit request help
from the Forum department...
PLC SY/MAX
Topic: PLCs and related questions.
Posted by Patxi Mugica on 5 November, 2008 - 7:20 am
Software for SY/MAX
from the Forum department...
Earth fault
Topic: Engineering and workplace issues.
Posted by arash on 5 November, 2008 - 7:06 am
Earth fault!!!
from the Forum department...
Protool Runtime on PDA
Topic: Human-Machine Interface and SCADA.
Posted by KS on 5 November, 2008 - 4:12 am
Is it possible to install ProTool Runtime on a PDA?
from the Forum department...
Problems discretising
Topic: Engineering and workplace issues.
Originally posted by ywk on 2 November, 2008 - 11:20 pm
Problems converting from continuous to discrete time.
New Replies:
By Friedrich Haase on 5 November, 2008 - 2:19 am -
Moin ywk... moin all, Z-Transforming a second order continuous system like your Gp(s) = 4 / (...
from the Forum department...
Omron as Modbus Master
Topic: PLCs and related questions.
Originally posted by jpm1 on 4 November, 2008 - 8:54 am
Omron as Modbus master
New Replies:
By Jerry Miille on 5 November, 2008 - 12:37 am -
I am not qualified to advise you how to configure your Omron to be used as a Modbus device. I can...
from the Forum department...
GE Frame 6: Change the start engine
Topic: Power generation equipment control.
Originally posted by Silvio Sosa on 4 November, 2008 - 8:05 am
I am investing ideas for converting a GE Frame 6B unit from a Diesel Start Engine to an electric motor start.
New Replies:
By CSA on 5 November, 2008 - 12:12 am -
Changing the starting means is possible, not inexpensive, but possible. You should start your...
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.