Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Search

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
Simon's Law:
Everything put together falls apart sooner or later.
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
Posts from...
Thursday, November 6, 2008
from the Engineering department...
How to add MA output signal to Mark 5 panel?
Topic: Software, including programming, OS issues, etc.
Originally posted by SAHA on 3 November, 2008 - 11:06 am
How to add MA output signal to Mark 5 panel?
New Replies:
By CSA on 6 November, 2008 - 11:52 pm -
Do you want to add an output from <C> or from <Q>?...
from the Instrumentation department...
EDDL
Topic: Software, including programming, OS issues, etc.
Originally posted by stem_p1st on 28 October, 2008 - 3:04 am
How can Emerson Instrumentation Equipment be configured by PACTWare?
New Replies:
By stem_p1st on 6 November, 2008 - 11:51 pm -
Thank you very much, I will follow up your suggestion right now and I am also trying to contact the...
By Chris Turcotte on 6 November, 2008 - 5:36 pm -
There are universal DTMs that support devices that only have DDs supplied by the manufacturer. It...
By stem_p1st on 6 November, 2008 - 4:14 am -
Hello, Thank you for your replies. If you don't mind, tell me how to embed the DD that I got so...
from the Forum department...
Multiplexing sensors on a 4-20ma loop
Topic: Sensor technologies.
Originally posted by sandeepa on 6 November, 2008 - 1:59 am
Multiplex sensors and send data on a current loop
New Replies:
By Roy Matson on 6 November, 2008 - 11:40 pm -
You could use remote I/O over ethernet or some other two wire protocol. Give us some more detail...
from the instruments department...
Thermcouple
Topic: Sensor technologies.
Originally posted by a_m_shiha on 6 November, 2008 - 2:43 am
Wiring thermocouple
New Replies:
By Roy Matson on 6 November, 2008 - 11:36 pm -
Anything's possible, but it won't be as accurate as if you use the correct extension cable. You...
from the Instrument department...
Thermocouple Extension cable sizing
Topic: Engineering and workplace issues.
Originally posted by YZD on 6 November, 2008 - 8:14 am
I need some help in calculating thermocouple K type core cable sizing for 350 meters long.
New Replies:
By Roy Matson on 6 November, 2008 - 11:30 pm -
You shouldn't have a voltage drop problem unless you are connecting to a low impedance load, e.g....
from the Bubbler debate department...
Bubbler level measurement
Topic: Open interfaces, software and hardware
Originally posted by Me on 6 November, 2008 - 8:19 am
Do we need a flowrater in bubbler method?
New Replies:
By Roy Matson on 6 November, 2008 - 11:23 pm -
No, you don't need a rotameter, in fact you don't even need a regulator or needle valve. You just...
By David on 6 November, 2008 - 10:36 pm -
You need a differential regulator which can produce a constant gas flow rate under varying head...
from the Forum department...
Circuit Breaker Duty
Topic: Engineering and workplace issues.
Originally posted by R.Shaikh on 6 November, 2008 - 6:44 am
Make and break duty of circuit breaker
New Replies:
By Phil Corso on 6 November, 2008 - 10:43 pm -
Responding to Shaikh's 06-Nov-08 (06:11) query... there are two types of electrical faults;...
from the Power department...
Unbalanced Load Calculation
Topic: Engineering and workplace issues.
Originally posted by Roy Matson on 21 December, 2007 - 12:34 am
How to calculate power in unbalanced load
New Replies:
By Son on 6 November, 2008 - 9:11 pm -
Unbalanced systems can be evaluated by computing phase current and then apply Kirchoff's law...
Topic: PLCs and related questions.
Originally posted by Dallas on 7 August, 2008 - 12:53 am
I am currently working on a PLC project. I would like to establish a master and slave communication using Modbus protocol.
New Replies:
By John Engle on 6 November, 2008 - 9:03 pm -
Simplest: Use the IO Scanner Wizard from the Configuration Extensions. More Complex: Use the...
Topic: Communications systems and equipment.
Originally posted by Topak on 4 November, 2008 - 4:42 am
Plantstreamer 1.0 r2 software
New Replies:
By Adriel Michaud on 6 November, 2008 - 6:15 pm -
Plantstreamer uses OPC DA. MatrikonOPC's OPC Explorer...
from the Automation List department...
Carter Wind Turbine Controller Interface - Modbus?
Topic: Communications systems and equipment.
Originally posted by Darran on 8 August, 2008 - 8:09 pm
Is there anyone out there that might know anything about the Active Control Inc. serial comms protocol used by Carter wind turbines?
New Replies:
By Darran P on 6 November, 2008 - 5:51 pm -
Only just found this response... the turbine is in the UK. The current owner wants to get the...
Topic: Power generation equipment control.
Originally posted by krchome on 4 November, 2008 - 6:24 pm
Gas Control Valve Calibration procedure (Mark IV & V)
New Replies:
By krchome on 6 November, 2008 - 4:40 pm -
Hi, Thanks for replying. I must admit that I hardly remember anything substantial for Mark IV....
from the Quest for Power department...
Heavy-duty Linear Actuator
Topic: Motion control, servos, steppers, etc.
Posted by damiod on 6 November, 2008 - 3:35 pm
Looking for heavy duty actuator for outdoor use.
Topic: Engineering and workplace issues.
Originally posted by Anonymous on 3 December, 2005 - 6:29 pm
what kind of electrical CAD software is most used by you guys?
New Replies:
By Roland on 6 November, 2008 - 3:17 pm -
He is right. EPLAN is not even expensive as said earlier. Try the new EPLAN Electric P8. It comes...
from the I&C department...
Rockwell OPC A and E Server
Topic: Software, including programming, OS issues, etc.
Originally posted by Peter on 3 November, 2008 - 10:20 am
An OPC Alarm & Event Server available from Rockwell
New Replies:
By peter2008 on 6 November, 2008 - 2:56 pm -
Thanks, Trevor....
from the C&I department...
UCVE card replacement in MarkVI
Topic: PLCs and related questions.
Posted by Dharmesh Oza on 6 November, 2008 - 2:00 pm
We want to change UCVE card in "R" processor but are not allowed to do so.
from the Not so Fail Safe department...
Fail Safe
Topic: Application Questions and Problems
Posted by cmdFailSafe on 6 November, 2008 - 1:38 pm
Resources for researching "Fail Safe"
from the Forum department...
Motor Starter with Stuck Button Detection
Topic: Engineering and workplace issues.
Originally posted by Fluoronator on 5 November, 2008 - 11:08 am
Looking for a method to detect stuck start buttons to prevent unexpected motor start-up when controls are energized.
New Replies:
By James Ingraham on 6 November, 2008 - 1:19 pm -
Most variable speed drives behave as you describe. If this is an important feature for you and a...
By Phil Corso on 6 November, 2008 - 12:35 am -
Responding to Fluoronator's 05-Nov-08 (11:08) query: See Control List thread #1026215647. It...
from the I should know this department...
Modicon Concept V2.6
Topic: Programming languages.
Posted by DCZang on 6 November, 2008 - 12:09 pm
When saving a Reference Data Editor in Concept, can anybody tell me the difference between a Reference Data Editor saved as an *RDE vs *RDF??
from the Engineering department...
Infi90 WINCAD
Topic: Engineering and workplace issues.
Originally posted by Ravi on 25 October, 2008 - 10:33 pm
ABB Bailey/Wincad
New Replies:
By Jerry on 6 November, 2008 - 8:47 am -
Greetings Ravi, Please answer the following. What is your: 1. Computer Operating System? 2....
Topic: Engineering and workplace issues.
Posted by Dillon Abdool on 6 November, 2008 - 8:42 am
Requesting information/advice.
from the sawmill hydraulic servo valves department...
Servo valves
Topic: Information resources, documentation.
Originally posted by dan on 4 November, 2008 - 2:40 am
How do you null a servo valve (Moog)?
New Replies:
By John Ross on 6 November, 2008 - 8:18 am -
Dan, My experience with servo valves was on a non-critical failure process where there was a...
from the Control department...
ESB Bus Coupler
Topic: Engineering and workplace issues.
Posted by sanjib on 6 November, 2008 - 8:05 am
How do four Local Node Units communicate with Field Control Unit through ESB Bus Coupler In Centum CS 3000 Yokogawa DCS?
from the Instrumentation & Control department...
Foundation Fieldbus
Topic: Communications systems and equipment.
Originally posted by sanjib on 3 November, 2008 - 3:36 am
What is the fieldbus device?
New Replies:
By sanjib on 6 November, 2008 - 7:53 am -
Thank you sir for your valuable answer....
from the Control department...
ProSafe-RS Connect with CS3000 DCS
Topic: Programming languages.
Posted by sanjib on 6 November, 2008 - 7:48 am
How we can connect ProSafe-RS PLC with Centum CS3000 Yokogawa DCS with the help of Modbus RTU ALR121?
Topic: Power generation equipment control.
Originally posted by BS Jhala on 2 November, 2008 - 11:11 pm
Effect of low atomising air temp in GE Frame 9E gas turbines.
New Replies:
By BS Jhala on 6 November, 2008 - 7:08 am -
Replies to CSA... 1) Yes all four machines have same type of check valves. 2 and 3) We have...
from the head screw up here department...
Home electric heater
Topic: Application Questions and Problems
Originally posted by warren oie on 3 November, 2008 - 8:53 pm
How do you determine wire size for an electric furnace (home heating unit) installed 40 feet from 200 amp breaker panel? Unit has 3 - 60 amp electrical breakers, is 280/240V Lennox Model ES03.
New Replies:
By Roy Matson on 6 November, 2008 - 6:05 am -
You need to tell us what voltage you are connecting to, Kw rating of heater. Your location is US,...
from the Automation List department...
Embedded systems in Hyderabad
Topic: Information resources, documentation.
Originally posted by suresh on 30 June, 2006 - 10:17 pm
Would u suggest any institution for embedded systems in hyderabad?
New Replies:
By kpendharkar on 6 November, 2008 - 5:32 am -
I'm feeling very confused after reading all these things. I'm a fresher in BE elect & tel,...
from the Automation List department...
Mitsubishi Melsec PLC cable diagram
Topic: PLCs and related questions.
Originally posted by Pullin Shah on 5 December, 2003 - 11:53 pm
Can anyone provide me with a cable diagram for connecting a Mitsubishi Melsec PLC (F1-30MR) to a PC via the comm port?
New Replies:
By sanjay on 6 November, 2008 - 4:17 am -
Yes, you can use sc02n cable to connect it with PC com port....
from the Maintenance department...
Load Rejection in ISOC mode
Topic: Human-Machine Interface and SCADA.
Originally posted by Iqbal on 15 August, 2008 - 1:52 am
During parallel operation, trip of another GT, enabled the load pick up in GT with mark V. Soon this GT start rejecting the load with speed dropping.
New Replies:
By Iqbal on 6 November, 2008 - 2:00 am -
We made an investigation with the support of GE control engineer. It has been found that the isoch...
from the DCS department...
Teleperm XP pumps control
Topic: Power generation equipment control.
Posted by 4_20ma on 6 November, 2008 - 1:41 am
Could anyone explain what is group control (GC) and sub-group control (SGC) in Teleperm XP of Siemens DCS?
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2008 Control Technology Corporation. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Internet Explorer 6.0 Fix

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!