1
Control.com member...
Member Information and Posts by 12345
from the C&I department...
GE Frame 9 compressor inlet pressure
Topic: Power generation equipment control.
Originally posted by Jack Peterson on 26 October, 2009 - 7:47 am
What are the probable causes of a high compressor inlet pressure.
New Replies:
Some questions - 1. Please check if these are 63CS series switches or otherwise 2. what are these...
from the p &U department...
fuel change over problem
Topic: Power generation equipment control.
Originally posted by S Das on 18 September, 2009 - 1:21 am
fuel change over problem
New Replies:
I have some experience on Naphtha fired units with more or less the same kind of arrangement (HSD...
Topic: Power generation equipment control.
Originally posted by HSB on 23 September, 2009 - 7:17 pm
Why is FSR value different when TNR value is same for 4 units?
New Replies:
Good observation, but what it seems is that the TNR value you have mentioned is quite minimal. ...
from the Power & Utilities department...
GT Trip on IGV control trouble
Topic: Power generation equipment control.
Originally posted by Samarendra Das on 17 September, 2009 - 12:46 am
GT Trip on IGV control trouble
New Replies:
The originator has a problem of IGV control trouble trip with CSGV moving down and under a prefixed...
Topic: Power generation equipment control.
Originally posted by HSB on 21 September, 2009 - 10:55 am
We have 106 MW, GE Frame 9E gas turbine of control system mark-IV. Before 2 months our GT tripped at 60% speed due to IGV trouble
New Replies:
What I understand is that under any given circumstances it is not normal for the actual exhaust...
Topic: Power generation equipment control.
Originally posted by Pirate on 24 September, 2009 - 2:57 pm
What is the increment/decrement rate of TNR in Speedtronic MARK IV control system
New Replies:
Well that was a great piece of discussion. Some really hard brain storming to clear the facts. It...
Topic: Power generation equipment control.
Originally posted by Nimesh Patel on 16 August, 2009 - 8:18 pm
What is "Cross Tripping" in speedtronic Mark iv controlled gas turbine?
New Replies:
Thanks CSA as always for the detailed explanation. Actually I just overlooked that it was Mark-IV. ...
I have heard of TCEA cross trip which directly relates to L4_XTP. Refer your control sequence for...
Topic: Application Questions and Problems
Originally posted by Info Seeker on 10 September, 2008 - 1:05 am
Trying to reason out why tripping of a Gas Turbine is not considered on LUBE OIL TANK level LOW LOW.
New Replies:
Dear Gary, for frame-V machines, frankly speaking, I have never heard of anything like high...
from the Forum department...
Varying load angle of alternator
Topic: Power generation equipment control.
Originally posted by Ashish on 17 August, 2009 - 5:31 pm
what are the different ways to vary the load angle of an alternator?
New Replies:
Load or torque angle can be varied by either changing the exciter field current or by the current...
from the Operation department...
Why underfrequency tripping of Gas Turbine
Topic: Power generation equipment control.
Originally posted by Nimesh on 5 August, 2009 - 6:21 am
What is the effect of under frequency in steam turbine & gas turbine especially in rotor blade & casing material vibration?
New Replies:
Hi, Underfrequency i.e. underspeed protection, is a part of protection set-up for the turbines. ...
from the Turbine Controls Engineering department...
GE Frame 5 limited below Rated Power
Topic: Power generation equipment control.
Originally posted by colladj1 on 14 August, 2009 - 9:52 am
GE Frame 5 limited below Rated Power
New Replies:
With miniscule details, it is very difficult to comment. Provide more details for a to-the-point...
Topic: Power generation equipment control.
Originally posted by GenProSpec on 7 August, 2009 - 5:09 pm
7FA Tripping on Low Hyd. Trip Oil pressure
New Replies:
Hi, In addition to what has been suggested, I understand that it would be of some help to you to...
from the Instrument And Control department...
GE Frame VI Gas Turbine Ignition trouble
Topic: Power generation equipment control.
Originally posted by Jatin on 30 April, 2009 - 7:38 am
GE Frame VI gas Turbine starting ignition problem
New Replies:
Hi, In line with the issue, I would like to state that on liquid fired units, the problem of...
from the SIEMENs Gas turbine department...
Temperature control for GT SIEMENs V94.3A
Topic: Power generation equipment control.
Originally posted by GTEGAT on 16 June, 2009 - 4:48 am
What is the philosophy of Temperature control mode of GT SIEMENs V94.3A
New Replies:
What I understand about the Siemens machine is - when HCO system is in use, it pushes the rotor to...
from the control instrument department...
MK V problem L74CR
Topic: Continuous process industries, DCS questions.
Originally posted by hartanto on 28 July, 2009 - 12:42 am
diagnostic alarm - voter mismatch L74CR in <R> processor
New Replies:
QD1 is the digital I/O for the three cores and i.e. IONET connection between QD1 and individual...
The alarm by its name voter mismatch is a direct outcome of the misalignment amongst the cores...
Topic: Power generation equipment control.
Originally posted by dhruv on 24 July, 2009 - 3:59 pm
explain the logics related to auxiliary lube oil pump, emergency lube oil pump & turning gear motor for gas turbine
New Replies:
AS usual, an excellent reply from CSA...
Topic: Power generation equipment control.
Originally posted by Faisal F. Al-Masri on 22 July, 2009 - 5:06 am
Spread temperature for GE Frame 6 turbine is fluctuating between 100F and 300F
New Replies:
Spread programme is basically a combustion monitoring software. The accuracy of the program depends...
from the Instrumentation Maintenance department...
GE Gas turbine Frame VI Ratchet Trouble
Topic: Power generation equipment control.
Originally posted by chinmoyd on 17 July, 2009 - 2:55 am
Our GE Gas turbine Frame VI faces frequent ratchet trouble during shut down or cool down
New Replies:
Seems to be a problem with 20 CS, when you are pressing the plunger you are ultimately forcing...
from the Engineering department...
Turbine Vibrations
Topic: Engineering and workplace issues.
Originally posted by Prabhakar1949 on 13 June, 2009 - 12:44 pm
Reasons for high vibrations in turbines
New Replies:
Agreed that the case as you say is true (fluctuation in vibrations during day and night), but have...
Vibrations reasons (w.r.t gas turbines) - 1. Lube oil film failure 2. Low oil header...
from the Forum department...
lm6000_generator lube oil system
Topic: Engineering and workplace issues.
Originally posted by ctb on 2 July, 2009 - 11:06 pm
generator lube oil system
New Replies:
Just to clear a few points - 1. How does the sequence proceed even after you get the alarm...
from the mark v/gas turbine department...
mark v/gas turbine liquid fuel line purge
Topic: Power generation equipment control.
Originally posted by XPS on 30 June, 2009 - 5:12 am
Liquid fuel line purge logic problem and it's process
New Replies:
Hi CPPGUY, Can you eloberate on the point no. 2. I mean for changeover from one liquid fuel to...
Topic: Engineering and workplace issues.
Originally posted by flamesy on 25 June, 2009 - 7:14 am
need help with the flame scanners
New Replies:
Anytime while describing a problem, it is always advisable to provide the maximum number of inputs...
from the Forum department...
GE frame Generator Vibration Problem
Topic: Power generation equipment control.
Originally posted by _carlo_ on 23 June, 2009 - 4:03 am
GE frame Generator Vibration Problem and turbine trips
New Replies:
I had been through a similar problem at a site. One thing that could had been done in your case was...
from the maintenance departement department...
MARK IV IGV Standard Control Constants
Topic: Power generation equipment control.
Originally posted by kafil on 21 June, 2009 - 3:16 am
Values for MARK IV Standard Control Constants
New Replies:
LK86GVA1 - 7.5 DGA LK86GVA2 - 5 sec LK86GVT1 - 7.5 DGA LK86GVT2 - 5 sec These values would...
from the Operation department...
Steam Turbine oil system problem
Topic: Power generation equipment control.
Originally posted by Operation engineer on 18 June, 2009 - 7:31 am
Steam Turbine Auxilary oil pump and Emmergency oil Pump problem
New Replies:
From the details, you have mentioned it is extremely difficult to ascertain the cause since the...
from the mechnical department...
IGV Angle andd AHOP Problem
Topic: Engineering and workplace issues.
Originally posted by charlee_tango on 5 June, 2009 - 3:48 am
AHOP fails to start as IGV is below minimum position.
New Replies:
It is okay to disagree without being disagreeable - anonymous. I think the matter is being dragged...
Teaching a man to fish - is always a great thing but how about fishing in troubled...
IGV going below a preset value (LK3IGVF1)or over a value (LK3IGVF2) results in L3IGVFLT. L3 IGVFLT...
from the control department...
mark 2 speedtronic
Topic: Power generation equipment control.
Originally posted by vj on 12 June, 2009 - 3:17 pm
Difference between normal start and fast start
New Replies:
The information supplied by me is machine specific and hence the constants would vary. Move...
Difference is in the start-up cycle, if you are using a diesel engine as a start-up means then the...
from the Forum department...
Mark VI alarm
Topic: Power generation equipment control.
Originally posted by ibanez on 12 June, 2009 - 1:12 pm
unknown Mark VI alarm
New Replies:
Not sure but seems - temperature switch, standby start ac fan # 2. I am not sure if this is...
from the Automation List department...
Effects of increased load on generator without governor
Topic: Engineering and workplace issues.
Originally posted by electrics on 12 June, 2009 - 6:49 pm
What happens when you increase the load on a generator without a governor?
New Replies:
Your query seems to be a confusing. What I gather is that you would like to know the loading...
from the Instrumentation department...
GT seq Trb 3.src Temp control ref
Topic: Continuous process industries, DCS questions.
Originally posted by Seshan on 16 May, 2009 - 3:25 am
GT seq Trb 3.src Temp control ref
New Replies:
What CSA has stated is quite true, in our csp, the temperature control reference is TTRXV6 at...
from the Forum department...
GT Fuel Control "LOAD LIMIT"
Topic: Power generation equipment control.
Originally posted by JM on 9 June, 2009 - 1:14 pm
GT fuel display in "LOAD LIMIT"
New Replies:
From what I understand - FSRDWCK (FSR for MW fault) comes from L30F_CTD. Also L3DWBCOKZ would...
from the Powerhouse department...
Load Sharing Problem
Topic: Power generation equipment control.
Originally posted by Khalid Mehtab on 30 May, 2009 - 6:58 am
Load Sharing Problem b/w GE Jenbacher Gas Gesets & Caterpillar Gas Genset
New Replies:
Loading of a particular unit would depend on its droop factor (percentage of droop). A unit with 4...
from the INSTRUMENT department...
Speed hunting in Gas turbine Frame V
Topic: Power generation equipment control.
Originally posted by K K VERMA on 16 April, 2009 - 1:53 am
We are running turbine in Isochronous mode and it's speed hunting from 5090 RPM to 5115 RPM while it should be fixed at 5104 RPM.
New Replies:
In percentage terms - TNH variation is from 99.73 to 100.21. Check your TNKRIMN (Isochronous set...
from the Forum department...
DIAGNOSTIC ALARM HELP FILE
Topic: Power generation equipment control.
Originally posted by SAID SAAD on 16 May, 2009 - 4:27 am
I need copy of (DIAGNOSTIC ALARM HELP FILE )
New Replies:
In DOS, in F prompt (site specific files), search for 'diagc' or try view2.exe...
from the Forum department...
Heat recovery steam modulating dampers
Topic: Power generation equipment control.
Originally posted by Alsa3b on 30 May, 2009 - 2:32 am
Gas turbine exhaust passes to HRSG through the inlet damper in case of combine cycle and the steam production is controlled via modulating bypass damper.
New Replies:
Damper closure time delay is 80 sec, hence if within 80 secs, diverter damper is not fully closed...
from the Power & Utilities department...
HITech Pump Logic
Topic: Power generation equipment control.
Originally posted by S Das on 30 May, 2009 - 6:55 am
Any logic behind Naphtha to HSD Fuel C/o Logic linked to HITECH system !!
New Replies:
Hitec additive flow is maintained generally around 60 PPM. Logics related to C/O from Naptha...
from the field service department...
emergency lube oil sequence modification markv idos
Topic: PLCs and related questions.
Originally posted by GP on 3 May, 2009 - 4:20 pm
work around for til from ge (til 1420-2r1) which can be applied to the gas turbines frame 5-6-and 9 not not valid for the turbines and controls supplied after 2003
New Replies:
The question posted was not fully clear - especially the 30 min timer. But if your speed probes 77...
from the Forum department...
Why is TNR > TNH
Topic: Power generation equipment control.
Originally posted by AK on 18 April, 2009 - 4:09 pm
Calculating TNR and TNH
New Replies:
TNR is turbine reference value whereas TNH is the actual turbine speed. The turbine droop function...
from the Forum department...
Gas Turbine High Exhaust Temperature Trip
Topic: Power generation equipment control.
Originally posted by Gunga Chea on 17 April, 2009 - 2:37 am
Gas Turbine trips on High Exhaust Temperature minutes after starting.
New Replies:
Speed limiting at 2700 rpm Considering that you have a Detroit diesel engine, I feel in your...
1
 
 
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.