Member Login
Search
Jump to a Date
Sponsored Communities
Cool stuff
Twitter Feed
Neat Stuff

Visit our shop for nerds in control lifestyle products.
Thermal Overload
The threads that wouldn't die...
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
- PC reliability?
- Windows, real time
- PID loops
- PCs vs. PLCs
- Replacing people
- MS 'monopoly'?
- Software quality
- Where do we go from here?
- Why pay?
Fortune
For those who like this sort of thing, this is the sort of thing they
like.
-- Abraham Lincoln
like.
-- Abraham Lincoln
RSS Feed
www.control.com/rss/
To get a personalized feed, become a member at no cost.
1
Control.com member...
Member Information and Posts by DaveMHfrom the Manager - Instrumentation department...
SIL-2 Certified SIS transmitters Diagnostics integration in ESD systemI want to know if it a must to integrate HART diagnostics from SIS transmitter within the Plant asset management system to meet Target SIL
New Replies:
Giriskant,
To my knowledge no credit has ever been claimed, with respect to SFF, for any...
Dear Girishkant,
> Is it OK in the above situation that I use a single SIL-2 transmitter...
A computer virus caused serious problems recently for an Australian electric utility.
New Replies:
Michael,
I think that I am more or less in agreement with your sentiment. The problem I have is...
Hello Michael,
Thank you for posting this as I am trying to keep some kind of log on incidents...
Can any body tell me the minimum level of wattage of signal to ignite the hydrocarbon atm?
New Replies:
It is the amount of energy available to the fuel mix thats important and that can be delivered not...
Doubts about "generic" instrument
New Replies:
Marlon,
> So my question is do we need a SIL 2 rated instruments for the SIL1 loop? <
...
Ricardo,
You might be better giving us more details/better context to judge the use of these...
Problem in putting Invensys Connoisseur APC in closed loop
New Replies:
Dear Kuman,
I am not sure we have understood each other so bear with me for a moment.
My...
what's the difference?
New Replies:
I may have got the wrong end of these last few posts. Apologies if thats the case.
There's a few...
which contact (NO or NC) of limit switches are used for safety operation, if their is a failure in case of wire cut.
New Replies:
I would back up what M Griffin said previously about about
1) There being no single answer...
requirements to be defined as a SIL-3 PLC
New Replies:
Your appreciation of the typical conventions in industry related to safety systems are generally...
MTBF data for Bailey System
New Replies:
Can you contact ABB?
Failing that if you have a reasonable history of failed items and the times...
What is a transfer function.
New Replies:
Ritika,
I'll try and be brief.
Yes a transfer function is basically a (linear) way of...
Can SILa initiators be shifted to the DCS
New Replies:
This may be a bit late however I'd like to add the following.
1) Judging from the language used...
SIS related issue regarding risk acceptance criteria
New Replies:
Dear Jorge,
The short answer to your question is no.
There are a range of risks to be...
Logics for CO2 Release systems in case of Fire
New Replies:
Just to add to the previous post a couple of things.
1) Traditionally (in my expeience) fire...
Any way to avoid $15K in agency approvals?
New Replies:
Peter,
Sorry its taken a while to get back.
If I've got this right you have a device in a box...
Why does it have to be IS?
There are other means of protecting hazardous area equipment like...
to get help for explosion proof equipment
New Replies:
Generally yes you can use equipment designed for zone 0 in zone 1 and 2 as zone 0 design criteria...
There is ultimately no substitute for reading the standards as a previous post has commented. Other...
DCS or ESD?
New Replies:
Wow are you venturing into new and uncharted territory (for you) from the sounds of it.
What you...
Definition on "Integrated" Control Systems
New Replies:
I'm afraid in this sense the word integrated can mean whatever the vendor defines it to mean. There...
My boss wants to build a workbench to test the invulnerability of a simple SCADA system against hacker attacks.
New Replies:
I have to agree with the previous 2 postings but I'll go a little further.
1) No computer based...
from the Control eng department...
Choosing a Distributed Control System for the Crude Oil and Natural Gas Extraction PlantDCS selection, SIS, Modbus, Profibus
New Replies:
At first glance of your requirements just about any of the major vendors (Honeywell, Invensys, ABB,...
1
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.
Our Advertisers
Help keep our servers running...
Patronize our advertisers!
Patronize our advertisers!











