Control.com member...
Member Information and Posts by David_2
Topic: Communications systems and equipment.
from the Automation and EMS department...
Modbus Data transmission time
Originally posted by Bhadresh Sarvaiya on 12 April, 2014 - 7:58 am
How to calculate time to receive data from slave to master in daisy chain connection of slaves, if my slaves are 20 and single master.
New Replies:
Mr. Linse, What's a rule-of-thumb value for RTU-TCP latency in a Digi Modbus bridge product? ...
You know - the word size, 11 bits - the number of words in the master message - silent...
Topic: Continuous process industries, DCS questions.
from the Forum department...
Actuator indication and control
Originally posted by David Sutcliffe on 11 April, 2014 - 10:32 am
How to obtain indication and control from a Rotork actuator
New Replies:
Other types of actuators use two drive signals: - one signal drives the actuator 'open' - the...
Topic: Human-Machine Interface and SCADA.
from the Forum department...
Connecting Floboss 107 to DeltaV
Originally posted by John on 11 April, 2014 - 5:13 pm
Student with a project to connect a Floboss 107 to DeltaV for an HMI.
New Replies:
An analog output can't very well handle a totalizer value because of the lack of dynamic range on a...
Topic: Communications systems and equipment.
from the Forum department...
8-bit data types in Modbus registers
Originally posted by Jay on 10 April, 2014 - 5:26 am
Are 8-bit data types obsolete for Modbus?
New Replies:
> Since registers are always 16 bits, does it even make sense to provide data types of 8 bits...
Topic: Continuous process industries, DCS questions.
from the Forum department...
Condensate pots and flow measurement
Originally posted by Karthik on 12 April, 2014 - 3:36 am
Using condensate pots for flow measurements
New Replies:
1. The purpose of condensate pots in steam flow measurement is to isolate or seal the transmitter...
Topic: Communications systems and equipment.
from the Automation List department...
Communication of UDC3000 controller with Experion
Originally posted by Sachin on 5 April, 2008 - 1:27 am
I have connected the UDC3000 controller with Honeywell Experion SCADA via RS485. I don't have a deep idea about UDC3000 controller.
New Replies:
Latest edition of Honeywell's Modbus RTU communications manual 51-22-25-66, Rev T, dated February...
Originally posted by andyt76 on 24 July, 2012 - 7:19 am
Connecting a Honeywell UDC temperature controller to Modicon PLC via Modbus. any ideas on this?
New Replies:
Latest edition of Honeywell's Modbus RTU communications manual 51-22-25-66, Rev T, dated February...
Topic: Continuous process industries, DCS questions.
from the HC900-C70R department...
Split Range Control on two valves - HC900-C70R
Originally posted by Frederik on 8 April, 2014 - 7:45 am
Split Range Control on two valves - HC900-C70R
New Replies:
The pressure transmitter is the input to an analog input function block. Its analog value is the...
Topic: Software, including programming, OS issues, etc.
from the Forum department...
Problem in Modbus Master Simulation Tools
Originally posted by Rupak Shrestha on 4 April, 2014 - 4:26 am
I'm having problem to communicate over Modbus RTU and TCP/IP frame with my computer using free softwares such as Simply Modbus Master 7.1 and TCP Client 7.1, and Modbus Poll.
New Replies:
It sounds like you just don't have a connection. RS-485 has some issues. The A/B or (+)/(-)...
Topic: Engineering and workplace issues.
from the instrumentation department...
Loop calibration for 2 wire loops
Originally posted by - on 3 April, 2014 - 3:02 am
Loop Calibration for 2 wire loops from calibrator that gives 24VDC loop output power
New Replies:
Can you do a loop calibration? Probably. But you're on your own figuring it out. Kusam...
Topic: Sensor technologies.
from the Instrument department...
ABB Thermocouple Transmitter reading fluctuates
Originally posted by msalem73 on 29 March, 2014 - 6:42 am
Transmitters reading Fluctuating
New Replies:
6 different T/C transmitters with a 4 year history of proper operation which now fail-low...
1) What is an example of a 'good reading', for example, 215 Deg C? 2) What is an example of a...
Topic: PLCs and related questions.
from the Forum department...
Tri-Sen analog output low
Originally posted by JoeFin on 31 March, 2014 - 6:12 pm
Tri-sen TS 310 controller that doesn't want to output a full 20 ma signal
New Replies:
Page 40 of the TS310 User Guide states that the voltage driving the output is 7 volts and that an...
Topic: Sensor technologies.
from the Instrumentation & Control department...
Liquid gas level measurement
Originally posted by Engineer92 on 27 March, 2014 - 2:52 am
Liquid Gas Level measurement
New Replies:
> But we noticed that when tank level is 15%, pressure is around 5 bar & when level is 50%,...
Topic: Motion control, servos, steppers, etc.
from the Forum department...
Beginner question: starting an Altivar 12
Originally posted by Jaap P on 29 March, 2014 - 3:23 am
I'm trying to get an Altivar 12 running through modbus without succes. Any help greatly appreciated!
New Replies:
I'm hex illiterate. What's the URL for the device's modbus manual with a map?...
Originally posted by Mohid on 27 March, 2014 - 6:16 am
Trying to receive process parameters from an APB PLC to Honeywell DCS over modbus
New Replies:
DCS documentation is available only to the privileged few, which doesn't include me, so I can only...
Topic: Sensor technologies.
from the Very Low Pressure department...
Panel Pressure Transmitter
Originally posted by Paul Ganter on 17 March, 2014 - 2:37 am
I need to measure a very low pressure, not a DP.
New Replies:
You can't have your cake and eat it, too. > the internal pressure of the panel to ensure...
Topic: Software, including programming, OS issues, etc.
from the Forum department...
Final year project using Honeywell DCS
Originally posted by AbhilashKondodi on 26 March, 2014 - 11:42 am
Is there any inbuilt SCADA Software for Honeywell DCS HC900 C30?
New Replies:
Current firmware 4.4 (or higher) HC900 controllers can use flash memory in the controller's CPU for...
Topic: Software, including programming, OS issues, etc.
from the Electrical & Instrumentation department...
Unable to load DTM of HART Field Transmitter
Originally posted by Hoa on 24 March, 2014 - 11:02 pm
The Preventive Maintenance Server can not access Rosemount HART protocol transmitters
New Replies:
> all the field transmitters are losing the DTM Wrong. The field transmitters can function...
Topic: PLCs and related questions.
from the Automation List department...
So What did I use the Clicks for?
Originally posted by Curt Wuollet on 22 March, 2014 - 8:37 pm
Real world example of using the Koyo Click PLC
New Replies:
Super Review. Thank you. Is the $99 model with the 485 port a Modbus slave only, or can it be...
Topic: Sensor technologies.
from the Instrumentation department...
I/P issue
Originally posted by Syed Misba on 21 March, 2014 - 10:56 am
4-20 mA & rosemount I/P transducer causing problems
New Replies:
Thank you for providing the resolution to the forum....
Topic: Communications systems and equipment.
from the Forum department...
Modbus Register Set
Originally posted by JAspinall on 16 March, 2014 - 10:31 am
Is anyone able to point me in the right direction as per configuring this register set based on my Modbus list?
New Replies:
One of two situations is likely - word order mixup or mixing words from different values. ...
Topic: Continuous process industries, DCS questions.
from the Forum department...
Using an MTL 7706+ Barrier eith HART
Originally posted by Allan Doc on 14 March, 2014 - 1:42 pm
MTL 7706+ barrier suitable with HART?
New Replies:
Your co-workers and colleagues are the people who can tell you whether it works or not. It...
Topic: Continuous process industries, DCS questions.
from the PLE department...
Boiler Combustion Air Flow
Originally posted by Abu Raihan on 14 March, 2014 - 7:51 am
Best practices for Boiler combustion Air flow measurement in DCS or PLC.
New Replies:
A reason for doing square root in the DP transmitter is that it is functionally a flow transmitter....
Topic: Continuous process industries, DCS questions.
from the instrumentation and control engg department...
Proportional control
Originally posted by saarathi on 5 March, 2014 - 4:18 am
why the response of proportional control is exponential?
New Replies:
I didn't understand the question either. Maybe a damped approach to setpoint with no overshoot...
Topic: Engineering and workplace issues.
from the Instrumentation department...
Pressure transmitter
Originally posted by Aster Guillermo on 11 March, 2014 - 4:53 pm
What will happen when connecting the 4-20 mA output of one transmitter parallel to other transmitters slot of PLC?
New Replies:
> is it possible to connect a transmitter output to another transmitter? No. > if we...
Originally posted by instrumentation on 28 February, 2014 - 11:10 am
Using SCADA communications with a UT 35A controller
New Replies:
The 3rd digit in the model number defines which comm protocol/transport layer your 35A has. none,...
Topic: Sensor technologies.
from the Forum department...
level control in grain silo
Originally posted by Old digger on 27 February, 2014 - 10:10 am
What do you use to monitor the level of grain in a silo?
New Replies:
The Siemens LR560 radar was made for grain silos. Its start-up wizard even asks whether the...
Topic: Continuous process industries, DCS questions.
from the Forum department...
Actuators requiring 50 mA current
Originally posted by Jimmy Mascrehnas on 23 February, 2014 - 6:48 pm
How do actuators requiring 50mA current work?
New Replies:
2 wire, loop powered, 4-20mA field transmitters use approximately 3.5-3.6mA to run the device's...
I think you've answered your own question; whatever device is using a 50mA control signal needs...
Originally posted by fabio on 25 February, 2014 - 9:44 am
Using an Explosion proof loop in a NEMA4x Junction box
New Replies:
No, not in the hazardous area....
Topic: PLCs and related questions.
from the Shiplift department...
Malfunction of Analog Input Module
Originally posted by Siemens on 22 February, 2014 - 2:03 am
Problem related to Siemens analog input module
New Replies:
What kind of load cell do you have that outputs a milliamp signal? Most load cells have a...
Topic: Engineering and workplace issues.
from the Forum department...
Signal conditioner
Originally posted by Bill Schwarz on 13 February, 2014 - 10:02 am
200 mA input signal conditioner?
New Replies:
The API 4300 G spec sheet says it has an input range up to 900mAdc and a selection of conventional...
Topic: Software, including programming, OS issues, etc.
from the R&D department...
Help with MODBUS Address
Originally posted by gil on 2 February, 2014 - 7:26 am
Help needed with writing a bit (true/false) to a modbus adress
New Replies:
The inverter/drive is a Modbus slave. You need a Modbus master to initiate a write command to...
Topic: Software, including programming, OS issues, etc.
from the Forum department...
MODBUS memory-map requirements
Originally posted by mbusland on 29 January, 2014 - 3:45 pm
Minimum requirements for memory-map.
New Replies:
Do you have some means of configuring the slave address? DIP switch? One thing that's missing...
Topic: Software, including programming, OS issues, etc.
from the Communications department...
How do OPC works?
Originally posted by Daniel on 23 January, 2014 - 9:09 am
How do OPC works and what are the differences with other protocols?
New Replies:
In OPC, the OPC server has the low-level driver that talks the comm protocol of the field device. ...
Topic: Sensor technologies.
from the Measurement department...
Measuring pressure & temperature in circular pipes
Originally posted by Smithy on 20 January, 2014 - 9:07 am
How do I calculate straight length requirements for pressure & temperature measurements in a pipe?
New Replies:
I knew I'd seen a reference to a pressure tap location spec somewhere but it took a day to recall...
For temperature, you get the temperature for point in the flow profile the tip of the thermowell...
Originally posted by jon fukuki on 11 January, 2014 - 10:38 am
Forced balance temperature transmitter calibration
New Replies:
If it's a true force balance transmitter, the style with the diaphragms stacked on "top' of...
Originally posted by any on 5 January, 2014 - 7:51 am
Illegal response message from Modbus from atlas copco MKIV gateway which is CAN to rs485 wired to rs232 converter to a pc.
New Replies:
I've heard that JBus is a minor derivative of Modbus, but I had never heard that the CAN protocol...
Topic: Local and wide area networking in factory automation.
from the Forum department...
default slave id configuration
Originally posted by mbusland on 28 December, 2013 - 12:36 pm
How to setup the default slave-id when shipping device to customers.
New Replies:
Anyone who implements Modbus (or any protocol) routinely expects to configure a slave address on...
Originally posted by Manas on 28 December, 2013 - 10:36 pm
Is it possible to connect j type thermocouple with k type extension wire up to transmitter?
New Replies:
The bad data from mixing wire types makes me shudder. You can't dig up some J wire to do it right...
Topic: Software, including programming, OS issues, etc.
from the software department...
modbus floating point format
Originally posted by mbusland on 21 December, 2013 - 9:34 pm
Is it mandatory to use IEEE Format for representing floating point in 2 16bit registers?
New Replies:
I love Banner Engineering's documentation because they explicitly provide the format and then give...
Originally posted by Ranjith on 22 December, 2013 - 2:37 am
Using Multicore cable for 4-20ma signal from Transducer to Scada Interface panel.
New Replies:
Why not? According to my chart, 1 mm2 is a size somewhere between 18 and 16 AWG. That's more...
Topic: Engineering and workplace issues.
from the Instrument department...
Redundant Server vs Dual Redundant Server
Originally posted by Utz on 18 October, 2011 - 1:25 am
is there any difference between the two things in the subject?
New Replies:
If Rosemount can, why not you, too? pg 13, 3144P manual: Hot Backup® provides temperature...
Originally posted by Sakthi venkatesh on 21 December, 2013 - 6:15 am
How to calibrate and communicate HART transmitter along with 475 communicator using DRUCK DPI 610 24 voltage power source?
New Replies:
We must have found different manuals on the web. The manual I found for the Druck DPI 610 (User...
Topic: Sensor technologies.
from the Instrumentation department...
Differential Pressure Teasing Question
Originally posted by SB on 11 December, 2013 - 1:13 am
For the trapped flow through the orifice, will any differential pressure be created?
New Replies:
No, the DP across an orifice plate will diminish as the static pressure equilibrate in its closed...
Topic: Continuous process industries, DCS questions.
from the Process Control department...
Watlow F4 not being detected
Originally posted by Paul on 29 November, 2013 - 9:39 am
Watlow F4D will communicate with one computer but is not detected on another.
New Replies:
> There's no option with the card to turn off the flow control, Isn't flow control done in...
Topic: Local and wide area networking in factory automation.
from the Forum department...
HART communication
Originally posted by P. Mahesh on 25 November, 2013 - 5:04 am
HART multidrop limitation
New Replies:
The limitation is a HART 5 limitation, according to the HART Foundation's HART Communication...
Select Page: 1 2 3 4 5 6 7 8 Next
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2014 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
Fuch's Warning:
If you actually look like your passport photo, you aren't well
enough to travel.
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive