Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
"A power so great, it can only be used for Good or Evil!"
-- Firesign Theatre, "The Giant Rat of Summatra"
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
1
Control.com member...
Member Information and Posts by Harvard
from the Control department...
Modbus protocol, HVAC system control
Topic: Communications systems and equipment.
Originally posted by JD on 13 August, 2009 - 1:14 pm
Return strings from Modbus simulator application differ from that of HVAC system harware
New Replies:
It is not unusual to have byte reversal issues. One of the devices, Host or Slave, should have a...
from the Forum department...
Convert SIMATIC to MODBUS address
Topic: PLCs and related questions.
Originally posted by martin on 12 August, 2009 - 1:02 pm
Convert SIMATIC to MODBUS address
New Replies:
To poll Address 11, Reg 40001 for 2 Regs: 0B 03 00 00 00 02 C4 A1 To poll Address 12 register...
from the Forum department...
Modbus frame size
Topic: Communications systems and equipment.
Originally posted by Bin on 6 August, 2009 - 5:25 am
Can I use the Modbus frame size larger than 256 bytes?
New Replies:
No! If you notice in the Function Code 3 slave response the 3rd byte is the byte count of the data...
from the Forum department...
MODBUS and flow meter
Topic: Software, including programming, OS issues, etc.
Originally posted by zabee on 29 July, 2009 - 1:26 am
how a flow meter communicate
New Replies:
I think you are saying you need to convert pulses from the flow meter to an accumulator that...
from the RS-485 department...
Modbus ASCII RS-485
Topic: Communications systems and equipment.
Originally posted by Vinod Gavande on 29 July, 2009 - 1:32 am
How many slave devices cab be multidroped on RS-485 bus?
New Replies:
The Master is just another device, so 32 including the Master is your correct answer. Remember, the...
Topic: PLCs and related questions.
Originally posted by K Grasty on 14 July, 2009 - 10:08 am
communications monitoring on PLC's
New Replies:
The most common method of making a "Watch Dog Timer" is to have a Modbus register...
from the Communication department...
Yokogawa Centum CS 3000 & 3500/92 Communication
Topic: Communications systems and equipment.
Originally posted by Vibcone on 12 July, 2009 - 4:03 am
Error in reading Analog Data from Holding registers
New Replies:
1. Parity is redundant with CRC checking, so you might disable parity else you may limit full...
from the Design department...
Modbus RTU protocol format with ODD PARITY
Topic: Communications systems and equipment.
Originally posted by vijeta on 1 July, 2009 - 1:45 am
What is the MODBUS RTU PROTOCOL format for ODD PARITY?
New Replies:
Parity is redundant and never normally used WHEN CRC error checking is implemented. Parity is not...
from the Forum department...
Software simulator as Modbus device
Topic: Communications systems and equipment.
Originally posted by dan on 16 June, 2009 - 6:29 pm
Modbus adaptor
New Replies:
I think you are asking for a ModBus Slave Simulation application that will respond to any ModBus...
from the Automation & Control department...
MODBUS Analog Input
Topic: Local and wide area networking in factory automation.
Originally posted by Tashar on 9 June, 2009 - 12:41 am
Does a MODBUS AI (MAI) make sense??
New Replies:
Modbus has Holding Registers and Input Registers. You cannot write to a Input Register, it is for...
from the Networking department...
Modbus RTU Passive Taps
Topic: Local and wide area networking in factory automation.
Originally posted by Shawn H on 29 May, 2009 - 11:55 am
How long can the taps on a modbus network be and are you limited to the amount of taps for 32 devices?
New Replies:
RS485 2 wire 1/2 duplex cannot have any "Tap length". There are only 2 ends to an RS485...
from the Forum department...
micrologix 1400 and modbus rtu woes.
Topic: Communications systems and equipment.
Originally posted by blackj on 19 May, 2009 - 4:26 pm
a question about modbus function codes, as well as looking for help with micrologix1400
New Replies:
Modicon Register 40001 is Modbus Register 0. The correct poll is: 01 03 00 00 00 02 C4 0B ...
from the Forum department...
TCP slave with separated memory maps
Topic: Communications systems and equipment.
Originally posted by DaleCooper on 5 May, 2009 - 9:39 am
TCP slave with sepparated memory maps
New Replies:
>//2b. Prepare a process image from 45001 to 45100 spi.setRegister(45001, new...
from the Can't talk to SATEC meter department...
MODBUS Communications Tester
Topic: Communications systems and equipment.
Originally posted by Thomas Toms on 27 April, 2009 - 2:52 pm
PLC Modbus Master will not talk to SATEC power measurement meter.
New Replies:
I have a freeware Win32 Console application that will monitor two RS232 1/2 duplex data streams...
from the Different versions of Modbus? department...
Modbus RTU on ABB AC250
Topic: PLCs and related questions.
Originally posted by Laban on 2 April, 2009 - 8:11 am
Are there different dialects of Modbus?
New Replies:
While there are variations I have never seen something as you describe. Here are two write...
from the Forum department...
Do you recognize this error checking?
Topic: Software, including programming, OS issues, etc.
Originally posted by Harvard on 31 March, 2009 - 11:23 am
Do you recognize this error checking?
New Replies:
Yes it is a 0x64, here are a few more from the same com link. f0 01 00 02 00 01 01 7e 9a f0 15 00...
from the Forum department...
modbus hardware
Topic: Computers in manufacturing; also hardware discussion.
Originally posted by luis canto on 31 March, 2009 - 7:14 pm
I need to use a special hardware?

New Replies:
If your LapTop has an RS232 port and the Modbus device also has an RS232 port then no converters...
from the Forum department...
connect multiple devices to RS-232
Topic: PLCs and related questions.
Originally posted by Abhijeet on 26 March, 2009 - 6:55 am
connecting multiple devices to modbus over rs-232 by using RS-232 to RS-485 converter
New Replies:
According to the Gould Modbus Protocol Reference Guide PI:MBUS-300 Rev B, a Function Code 7 has a 4...
There is a cheap and dirty method of connecting multiple RS232 slaves to one host using RS232 if...
See bb-electrocics.com for lots of good info on RS232 to RS485 converters. A good choice is their...
from the Plant Engg.-E&I department...
SIMOCODE/SIMOVERT Communication to Yokogawa CS-3000
Topic: Continuous process industries, DCS questions.
Originally posted by Mohamed on 22 February, 2009 - 2:10 pm
Is there any 3rd party tool s/w available in the market to pinpoint the type of failure in commn. from a particular slave?
New Replies:
If the moderators allow this to post, I have a freeware WIN32 Console application that will monitor...
Most intermittent Half Duplex COM errors are either associated with RS485 GND issues OR Timing...
Topic: Communications systems and equipment.
Originally posted by Mikey on 19 March, 2009 - 8:51 pm
modbus analyzing from the outside
New Replies:
Most likely caused by timing settings. I would verify the Slave "Turnaround Time" setting...
from the Trying to figure out modbus department...
Modbus RTU protocol questions
Topic: Communications systems and equipment.
Originally posted by Jesper on 26 February, 2009 - 3:19 pm
A few questions regarding the coding system of modbus RTU
New Replies:
>My 1st question: ANS: For RTU mode there is No Parity. RTU mode uses CRC error checking. An...
Topic: Local and wide area networking in factory automation.
Originally posted by ASh on 16 February, 2009 - 6:36 am
Problem connecting 2-wire modbus RS-485 to 3-wire Modbus RS-485 on daisychain modbus network.
New Replies:
Start with the MOXA 3180 and add one slave at a time. Do not be suprised if the Data+ and Data-...
from the Forum department...
Map variables to the modbus register
Topic: Programming languages.
Originally posted by spikecontrol on 9 February, 2009 - 6:44 pm
Variable mapping
New Replies:
I would use a C code "union" to accomplish this mapping, if I get your drift....
Topic: Engineering and workplace issues.
Originally posted by Timothy Burgess on 5 February, 2009 - 3:26 pm
Problems talking to a slave machine using the Modbus RTU protocol.
New Replies:
You will not get a response from a Modbus slave if the CRC is in error, it will be assumed to be...
from the Double Register Data Polling department...
Siemens Sentron PAC3200 Power Meter Energy Readings
Topic: Power generation equipment control.
Originally posted by Terence Ng on 4 February, 2009 - 12:43 pm
How can I retrieve the energy reading from Siemens Sentron PAC3200 power meter which is Double Register format?
New Replies:
These double registers are most likely IEEE Single Precision numbers. As such, they will be sent in...
Topic: Communications systems and equipment.
Originally posted by interop on 3 February, 2009 - 12:04 pm
Can only read 6 registers from Controlotron 1010 flow meter via Modbus
New Replies:
If this connection is Modbus RTU protocol then you would not want to be using parity and 7 bits....
from the Help with modbus RTU department...
Elpro 905u G / Adams 5000
Topic: Communications systems and equipment.
Originally posted by Adam Rayner on 1 February, 2009 - 12:03 am
Trying to read Reg 400001 from a Adams 5000E to a elpro 905u-G
New Replies:
>So should i set the radio to read register 40001 or just 0?< Probably 40001 and it will...
Modicon Register 400001 is a misprint, should be Modicon Register 40001 which is polled as ModBus...
from the Forum department...
Altus NOC problems
Topic: Application Questions and Problems
Originally posted by David Ralph on 3 November, 2008 - 1:45 pm
Data from the NOC is not resetting between tests.
New Replies:
Probably a timing issue, as in a race condition, associated with a fast communications connection....
1
 
 
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!