Member Information and Posts by Inst72what is the criteria of having a lube oil system in a particular motor/pump?
Criteria for having 2003 transmitters in an equipment
Transmitter failure mode and ESD transmitter validation logic standards
Best configuration for emergency shutdown system
Hello..
is there any difference between the two things in the subject.?
New Replies:
is it redundant server: 2 servers
and dual redundant: 4 servers...
How to select a solenoid valve wattage in a particular process valve?
New Replies:
Thanks to you CSA... this website is very helpful really... thanks thanks...
ESD Input is tripping pump
New Replies:
Thanks Sam.
Please be patient on me, i'm just a little kid in this industry. No experience in...
Hi Sam
Is the open circuit usually happen in the operating plant? (by means of loss connection,...
Hello Sam
Thanks a lot. I am thinking about the accident that the circuit could be open...
Can we combine DCS, ESD and F&G systems into one System?
New Replies:
I don't think so.
ESD and DCS could not be combine because of:
1. speed issue - as i know ESD...
What is permissive exactly?
New Replies:
Hello.
Another question in my mind, what is INHIBITION.
In our C&E diagram, some FAL (from...
Thanks a lot Sam....
Line Monitoring
New Replies:
Hi there,
I have the same understanding with you. I really don't know why our consultant...
Temperature loops shows input open even though the physical connection from the sensor to the system are all OK
New Replies:
>1) loops = plural
> sensor = singular
>Is this problem occurring on more than one...
Is it possible to use "Knife disconnect type" for Digital I/O?
New Replies:
Hi there,
Saying generally not necessary for digital input, analog output and input is very...
Why can't Rotameter read below 10% of FS?
New Replies:
Hi there,
Actually its a rotameter integrated with the transmitter, thus we have wiring on the...
Dear Sam,
Thanks.
As I understand, it requires some amount of force (flow) to move the float...
Dear Sam and cww,
Thanks a lot!
Let me clarify my understanding. As I understand, it requires...
Confused which solution is right.
DVC6010F Positioner (Foundation Fieldbus) connection fail on DCS and HART.
Signal to signal capacitance value of foundation fieldbus segment with two megablock exceeds the allowable value of 1 μF.
difference between "knife switch" and "fused type" terminal blocks at Marshalling side
Instrument enclosures and junction boxes and requirements for steel breather and drain fittings
New Replies:
A lot of thanks for the answer.
I would like to know if it has no impact against the hazardous...
Client requires valve size of 11/4, 21/2. 31/2, 5 or higher odd numbers shall not be used
New Replies:
>Interesting. Where from your client?
It's saudi aramco.... we are EPC based here in KSA...
Select Page: 1
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.