1
Control.com member...
Member Information and Posts by KirkC
from the DRAFTING department...
PLC Panels Drawings Software
Topic: PLCs and related questions.
Originally posted by SANTHIRAJ on 16 September, 2009 - 10:35 pm
choice of software for drafting PLC panel drawings and loop schematics
New Replies:
RE: Visio Like Ken Emmon Jr, I use Visio also. It is not fully ACAD compatible. That's a...
from the Forum department...
Modbus RTU Master in Program Master mode
Topic: Communications systems and equipment.
Originally posted by Frankan on 16 July, 2009 - 4:10 pm
Need a Modbus RTU Master OPC Server as "Program Master"
New Replies:
"Program Master" and "Data Master" are Modbus-Plus terms. Modbus-Plus supports...
from the Communication department...
Yokogawa Centum CS 3000 & 3500/92 Communication
Topic: Communications systems and equipment.
Originally posted by Vibcone on 12 July, 2009 - 4:03 am
Error in reading Analog Data from Holding registers
New Replies:
Parity adds a bit to check whether or not a serial word (byte) passes the test of having an even or...
from the Forum department...
SCADA Server and Real Time OS
Topic: Software, including programming, OS issues, etc.
Originally posted by kapil on 4 June, 2009 - 6:54 am
working on intouch 8.0 SCADA with Windows 2000
New Replies:
Wonderware is the name of a company, not the name of a product. Wonderware sells a software...
from the Forum department...
PLC Monitoring & Control over internet
Topic: Computers in manufacturing; also hardware discussion.
Originally posted by M. Bhamani on 3 June, 2009 - 9:46 am
Configuration - internet browser PLC access
New Replies:
Walt Boyes: > Just keep pinging the PLC over the Ethernet port. (grin) If you do it enough...
Topic: Communications systems and equipment.
Originally posted by PlcStud on 6 May, 2009 - 8:46 am
pin assignment of 110 XCA 282 comm. cable
New Replies:
I think that would be diagram "H" on page 34 of the Schneider/Modicon publication...
from the Communications department...
Wonderware Intouch SLQ Server DVD's
Topic: Human-Machine Interface and SCADA.
Originally posted by Jhon on 30 April, 2009 - 2:26 pm
SQL Server Licensing
New Replies:
John: Wonderware has some sort of agreement with Microsoft that allows Wonderware to furnish a...
from the Forum department...
Modbus RTU over TCP Slave Simulator
Topic: Software, including programming, OS issues, etc.
Originally posted by Jon Leininger on 15 April, 2009 - 2:16 pm
Testing a Modbus master using RTU over TCP
New Replies:
I know of no such thing as a Modbus RTU over TCP slave simulator. A Modbus RTU slave is a serial...
from the Forum department...
USB - RS232 for TISOFT2 (DOS program)
Topic: Software, including programming, OS issues, etc.
Originally posted by bartb on 7 April, 2009 - 3:03 pm
Using an old DOS program that relies on serial ports on a new PC without one.
New Replies:
Look here: http://www.expresscard.org/web/site/cons_wtb.jsp#seri I use the SIIG express card....
from the Kind of lost department...
Modbus RTU over Ethernet
Topic: Communications systems and equipment.
Originally posted by Craig on 2 March, 2009 - 1:05 pm
RTU over Ethernet Problem
New Replies:
That won't work, Craig. If you want to encapsulate Modbus RTU serial in a TCP or UDP packet you...
from the Trying to figure out modbus department...
Modbus RTU protocol questions
Topic: Communications systems and equipment.
Originally posted by Jesper on 26 February, 2009 - 3:19 pm
A few questions regarding the coding system of modbus RTU
New Replies:
Start, stop, and parity bits are added to your data words by the UART. Your program will never see...
from the Automation List department...
Why do you pay for PLC programming software?
Topic: PLCs and related questions.
Originally posted by Stephen on 6 June, 2002 - 9:45 am
A question that has been on my mind for some time...
New Replies:
Hugo wrote: >You and every one else who's thinking it would be nice if it's free better start...
from the Forum department...
little confused about telemetry basics
Topic: Engineering and workplace issues.
Originally posted by none on 27 January, 2009 - 10:29 am
I know about live zero concept, but I don't know that why are t
New Replies:
You are little confused about instrumentation basics, not telemetry basics. As you hunt around...
from the Instrumentation department...
DP Xmitter Range
Topic: Engineering and workplace issues.
Originally posted by Ghate Vinod on 27 January, 2009 - 6:22 am
Dp Transmitter & mathematics
New Replies:
Differential pressure can be used to measure flow. In the best of cases, the flow is proportional...
from the Forum department...
Looking for a small PLC
Topic: PLCs and related questions.
Originally posted by dss on 11 December, 2008 - 6:59 am
We are searching a small PLC to integrate in a 3U high (132 mm) /19 inches wide (482 mm) rack space.
New Replies:
You could mount a Schneider/Modicon Momentum or a Control Microsystems SCADAPack flat on a shelf. ...
from the Forum department...
Modbus TCP/IP with AutomationDirect DL06
Topic: PLCs and related questions.
Originally posted by Lance Snyder on 20 November, 2008 - 8:03 am
I have a question about Modbus TCP/IP communications with AutomationDirect PLC
New Replies:
You are contradicting yourself here. If the Modbus/TCP master were sending (writing) a 0 to V2446,...
from the Forum department...
DL06 to Modicon Quantum Comm
Topic: PLCs and related questions.
Originally posted by rwest on 17 December, 2008 - 4:01 pm
Has anyone ever communicated between Directsoft and Modicon Modbus?
New Replies:
Move the coil in the Quantum to a 4x register in the Quantum with a BLKM or SUB instruction for...
from the Forum department...
ControlLogix vs Quantum PLCs
Topic: PLCs and related questions.
Originally posted by Ryno83 on 29 September, 2008 - 10:58 pm
Pros and cons between ControlLogix and Quantum
New Replies:
James, I'd be starving now if I didn't make new Modicon applications. So now you've READ that at...
1
 
 
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.