Topic: Power generation equipment control.
from the Control department...
FSR Control
Originally posted by Ayman on 27 November, 2012 - 2:41 am
FSR control changing during base load
New Replies:
Dear CSA, >What is the frequency doing when FSR is toggling between Acceleration > and...
Topic: Power generation equipment control.
from the department department...
Auto Synchronization problem
Originally posted by Ayman on 4 November, 2012 - 9:21 am
synchroscope in HMI 180 degree different than the scope on GCPP panel
New Replies:
Hello, The different of 180 degree of synchroscope is solved by invert the wiring of bus...
Topic: Power generation equipment control.
from the Control department...
MOOG G771K200 problem
Originally posted by Ayman on 11 October, 2012 - 11:52 am
servo valve pulsate during starting
New Replies:
Dear all, The problem is not solved yet. We connect the rubber hoses to each of fuel supply...
Hello, The unit is new installed and its the first time to to do false fire. the hydraulic...
Topic: Power generation equipment control.
from the Control department...
Hydraulic Ratchet problem
Originally posted by Ayman on 24 June, 2012 - 2:24 pm
Hydraulic ratchet didn't work properly from time to time
New Replies:
Hello, The problem is gone after we turn on the ventilation fan for (3-5 min) and turn it off...
Dear all, The sequence of cooldown is: cooldown time: 10 hours ventilation fan running...
Hello, The problem is solved by sequencing the ventilation fan running time during cooldown. ...
Topic: Power generation equipment control.
from the Control department...
Rosemount Diff. Pressure transmitter problem
Posted by Ayman on 23 July, 2012 - 2:58 am
reading of the transmitter problem
Topic: Power generation equipment control.
from the CONTROL department...
Magnetic speed pickup
Originally posted by Ayman on 29 June, 2012 - 1:48 pm
Magnetic Speed Pickup Software Configuration
New Replies:
CSA, The unit is new and it is under commissioning. we make download of m6b file to all three...
Originally posted by Ayman on 23 June, 2012 - 12:15 pm
What is the cause of the Alarm Trip mult. activ. too long or too often?
New Replies:
Hello, Total starts 19 Total trips 9 thanks...
Topic: Power generation equipment control.
from the Control department...
Interface between Mark VI & Cimplicity HMI
Originally posted by Ayman on 8 June, 2012 - 1:14 pm
how to make interface between Gas Turbine MS5001 Mark VI & Cimplicity HMI project (***.GEF) file
New Replies:
Hello, the problem is solved by downloading configuration & firmware (Mark VI I/O ) thank...
Hello, its a list of the Diagnostic alarms that I have: <R> SLOT 2 UCVX DIAGNOSTIC...
Hello MIKEVI; I am talking about new installed unit gas turbine frame 5 MarkVI and we did these...
Topic: Power generation equipment control.
from the Control department...
Bleed Valve
Originally posted by Ayman on 12 June, 2012 - 12:55 pm
Bleed Valves is not closing at 95%
New Replies:
Dear CSA , Yes it's the same logic that I have , >> about bleed valve close after stop...
Dear all, I checked the logic of bleed valve. the command of bleed valve L20CB1X depended on two...
Select Page: 1
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
Oregano, n.:
The ancient Italian art of pizza folding.
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive