lube oil tank level
Originally posted by rajiv on 1 September, 2012 - 5:47 am
Lube oil tank level measurement
New Replies:
Ok this is getting very confusing. I will try and bring everything together. If we assume the...
CSA/Roy, thank you for the input, and yes you are right, but I just think from our side we should...
Topic: Sensor technologies.
from the H2SO4 acid close tank level measurement department...
H2SO4 acid close tank level measurement
Originally posted by VGUPTA on 23 January, 2012 - 9:08 am
we want H2SO4 acid level measurement for closed vessel so please suggest which type of level transmitter are suitable.
New Replies:
There are various instruments that will work in a application like this but with all of them the...
Topic: Sensor technologies.
from the I&E department...
Capillary type Seal Transmitters
Originally posted by Shahid Khan on 12 April, 2012 - 7:02 am
Queries - Instrument & Control section - Capillary type pressure transmitters
New Replies:
David is correct. The capillary lengths are determined purely by the application and the rule of...
Topic: Continuous process industries, DCS questions.
from the Split-Range Valves department...
Split-Range Valves model with Simulink
Originally posted by Jerome on 4 September, 2012 - 5:31 am
Split-Range valves model wit Simulink
New Replies:
I agree, there is no point setting up a level control like that. What we do have some times is two...
Topic: Engineering and workplace issues.
from the instrumentation department...
Control valve sizing
Originally posted by tushar on 18 June, 2009 - 6:53 am
How to calculate control valve sizing
New Replies:
Hi there, It is not all that complicated once you have the right formulas to work with. Here are...
Topic: Continuous process industries, DCS questions.
from the engineering department...
fallback strategy
Originally posted by saha on 31 October, 2010 - 1:38 pm
How does fallback strategy work in process control?
New Replies:
Hi there, Have a look at page 6 of this PDF link. It deal with standard and advanced features...
Topic: Human-Machine Interface and SCADA.
from the Automation List department...
Which SCADA is easy to use
Originally posted by Gary on 4 October, 2003 - 7:22 pm
Could anyone tell me which SCADA is more easily to use? I want to get more information about these.
New Replies:
Hi there, Well said by Paul. I also believe Intouch is very good and popular but then again so...
Topic: Continuous process industries, DCS questions.
from the brewing department...
level transmitter calibration
Originally posted by MSE on 3 November, 2010 - 4:08 am
Level transmitter and SCADA readings not synchronizing with each other after calibration.
New Replies:
Hi there, I can try to help but since I cannot be sure what have be done where, it is not...
Topic: Power generation equipment control.
from the I&C department...
New I & C engineer looking for advice
Originally posted by Ahmed on 2 November, 2010 - 2:49 am
I m new in I&C so may be many question in I&C
New Replies:
Hi there, Calm down Ahmed, all in good time. Your already on the right track in understanding...
Topic: Continuous process industries, DCS questions.
from the Instrument Deptt department...
Level Transmitter
Originally posted by Yogesh on 27 October, 2010 - 8:11 am
steam drum and de-aerator level transmitter range
New Replies:
Hi there, In both cases a wet leg installation is done with SMART positioners, that is why. I...
Topic: Continuous process industries, DCS questions.
from the i&c department...
Loop checking
Originally posted by a on 25 October, 2010 - 3:58 pm
Loopchecking TX in series or parallel with ma source with external power supply
New Replies:
Hi there, Yes you are probably right about the sinking and sourcing, I can never remember which...
Hi there, Ok let's do some loop checks without a HART communicator. You can use a mA source...
Topic: Power generation equipment control.
from the Condenser level department...
Vacuum condenser level xmtr
Originally posted by A.Eldessuki on 21 October, 2010 - 7:34 am
How we can solve the problems in vacuum condenser level transmitter.
New Replies:
Hi again, I agree with R Monge, especially a slow leak. Have you done all I suggested or why do...
Hi again, Fully agree, diagram remote seal is the best to use in a vacuum application. ...
Hi there, You have a leak somewhere. Look again at all the connections, disconnect from the...
Topic: Engineering and workplace issues.
from the I&C department...
Where to start?
Originally posted by Ali on 25 October, 2010 - 7:15 am
Becoming an Industrial Automation bachelor.
New Replies:
Hi there, Use Control.com to get answers to specific questions and also ask for links to...
Topic: Engineering and workplace issues.
from the Forum department...
RTD
Originally posted by Fasi on 24 October, 2010 - 7:25 am
Common in RTD
New Replies:
Hi there, Very well explained by CSA. Something else to keep in mind is that a RTD is also...
Topic: Continuous process industries, DCS questions.
from the Automation List department...
Control valve positioner
Originally posted by Hemanth on 8 March, 2007 - 10:56 pm
I would like to know the operation of positioner.
New Replies:
Hi there, Thanks for the effort, very interesting read. When you mentioned Siemens PS2 I all...
Originally posted by Ashwini on 8 October, 2010 - 3:21 pm
I need some help in choosing a mounting position for an orifice with a remote transmitter on a horizontal steam line
New Replies:
Thanks, very interesting read although only applicable to certain conditions....
Hi again, I would like to see this, do you have a link where to find it?...
Hi again, Yes Roy is right, you should use T-pieces if you do not want to use the catch pots...
Hi there, For orifice steam flow measurements it is very important to install the transmitter...
Topic: Continuous process industries, DCS questions.
from the Technical department...
Boiler Feed Water Flow Measurement
Originally posted by Chenzara H on 19 October, 2010 - 2:37 am
Requirements of a loop measuring boiler feed water flow
New Replies:
Hi there, If you need a local hardware recorder: ...
Topic: Sensor technologies.
from the Sensors for Vibration Measurement department...
Sensors for Vibration measurement
Originally posted by Dilip on 19 October, 2010 - 12:25 pm
I want to select reliable and cheaper type of sensors for vibration measurement of steam Turbine
New Replies:
Hi there, Make contact with Bentley-Nevada. They are one of the big experts when it comes to...
Topic: Sensor technologies.
from the need a glowing idea department...
Need level sensor for radioactive environment
Originally posted by Larry Cooley on 19 October, 2010 - 5:37 pm
Need help with level sensor spec.
New Replies:
Hi there, Hardened electronics are normally unique designs from scratch and therefore very...
Originally posted by D N on 19 October, 2010 - 11:09 pm
Two different glycol filling practices for DP transmitters; your thoughts and insights are most welcomed.
New Replies:
Hi there, In level, flow and pressure applications we just use a T-Piece on the bend just before...
Topic: Engineering and workplace issues.
from the instt department...
hot well level control
Originally posted by hi on 20 October, 2010 - 3:45 am
problem facing in measurement of hotwell level control
New Replies:
Hi there, You have done a dry leg setup instead of a wet leg setup in your installation. The...
Topic: Engineering and workplace issues.
from the Forum department...
RTD Cable Specs
Originally posted by Dennis on 13 October, 2010 - 2:33 am
RTD Cable Specs
New Replies:
Hi there, It does not matter what you use or what the cable resistance is as long as you do line...
Topic: Sensor technologies.
from the Department of Money Losing Jobs department...
Bouncing Current Loop
Originally posted by Bret Berger on 12 October, 2010 - 6:29 pm
1 mile long 4-20mA current loop bounces.
New Replies:
Hi again Also found this info for Ultra sonic level installations. 10. What is the maximum...
Hi there, The best will be to go wireless but if that is not possible, you need to look at this...
Topic: Engineering and workplace issues.
from the instrumentation department...
Calculating URV and LRV
Originally posted by ashfaq ahamd kahn on 10 October, 2010 - 5:23 am
what will be the URV and LRV
New Replies:
Hi again, Just my response to Roy's post. I agree with Roy that the GWR is obviously not...
Hi there, I can show you how to do the calculations but it will never work since you cannot use...
Topic: Continuous process industries, DCS questions.
from the Instrument and Control department...
HART communication I/O modules in DCS
Originally posted by Syed Waqar Azeem on 10 October, 2010 - 7:58 am
Which process variables are accessible in smart transmitters and smart positioners using HART I/O modules in DCS?
New Replies:
Hi there, In Smart positioners you can monitor the actual position of the valve and a alarm...
Topic: Information resources, documentation.
from the Forum department...
Newbie: Conceptual view of process control
Originally posted by New2Control on 5 October, 2010 - 9:39 am
I am not a control engineer of any kind, I am a developer and consultant at the business domain side of things. Gradually I am getting pulled more to process control side of things (from a conceptual point of view).
New Replies:
Hi there, I find your post very difficult and confusing and cannot understand what it is you...
Topic: Sensor technologies.
from the Forum department...
Measuring air alkalinity
Originally posted by Amarreddy on 5 October, 2010 - 9:45 am
Sensors to measure live data
New Replies:
Hi again, The GC is also called a energy analyzer and can actually tell you the composition of a...
Hi again, Ask these analyzer experts, I think they should be able to give you what you need....
Hi there, Just some interesting info, Clean air Composition: Nitrogen N2 78.084 % ...
Topic: Sensor technologies.
from the Forum department...
How to make a water level sensor
Originally posted by Awais Rauf on 10 August, 2009 - 6:25 am
How to make a water level sensor for water tank
New Replies:
Hi there, What the old Egyptians use to do in the years BC, was to take a float and attach a...
Topic: Sensor technologies.
from the Instrumentation department...
Interface Level Measurement
Originally posted by sanjib on 5 December, 2008 - 4:12 am
How can we measure Interface level measurement?
New Replies:
Hi there, I will tell you what not to use first, in case someone comes up with some bright brain...
Topic: Engineering and workplace issues.
from the INSTRUMENTATION department...
Measure boiler level
Originally posted by sanjib on 21 September, 2010 - 12:11 am
have to measure boiler drum level of 500 mm
New Replies:
Hi again, Sorry for the slow response but I had to do some traveling for two days. The...
Hi there, Need more info, What is the distance between the top and bottom tapping points on the...
Originally posted by moremgd on 3 September, 2010 - 9:31 am
Requesting feedback regarding use of magmeter versus ultrasonic meter for metering wastewater in a force main.
New Replies:
Hi again, I agree with Hamid. Also stay away from the portable Doppler ultrasonic test meter...
Topic: Continuous process industries, DCS questions.
from the Instrumentation department...
Rotork IQ range MOV remote command
Originally posted by Amir Qadri on 17 September, 2010 - 6:18 am
How convert rotork IQ range MOV remote open/close constant command into pulse command
New Replies:
Good man! Well done! ...
Hi again, You did not write very clearly and some things seems to contradict your first writing...
Hi there, Need more info if you want some help. Do you plan to change this signal to a pulse...
Topic: Application Questions and Problems
from the Forum department...
Replacement for a R7659 C117 Controller
Originally posted by Bob Ilich on 14 September, 2010 - 1:46 pm
Looking for a controller substitute where output is to a DC amplifier and then into a Thyristor Driving Unit.
New Replies:
Hi there, My suggestion would be to go for something simpler. The one I worked on before was...
Originally posted by satyadar on 14 September, 2010 - 8:12 am
doubts in co2 fire protection in manual non electric cabinet in ge 9001fa gas turbine.
New Replies:
Hi there, We use a different system but the workings of a shuttle valve is such that it allows a...
Topic: Continuous process industries, DCS questions.
from the PROJECTS department...
Radar Level Transmitter
Originally posted by SATHISH on 15 September, 2010 - 1:07 pm
Radar level transmitter for sulfuric acid and solvent toluene
New Replies:
Hi there, My suggestion would be to rather use a capillary DP transmitter with the correct...
Topic: Engineering and workplace issues.
from the Instrumentation department...
Pressure test
Originally posted by sanjib on 13 September, 2010 - 12:32 am
using pneumatic air for pressure test
New Replies:
Hi there, Air or gas is never used for pressure testing for the simple reason that there will be...
Select Page: 1 2 3 4 5 Next
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
Signs of crime: screaming or cries for help.
-- from the Brown Security Crime Prevention Pamphlet
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive