Member Information and Posts by PhilCorso
Member Name: Philip P. Corso
Originally posted by Ben on 16 May, 2013 - 5:32 pm
Several steps of external resistance used for speed control on motor appear to have uneven amounts of resistance. Is this possible? What will the effect on the motor be?
New Replies:
Ben, using the procedure I suggested illustrates how the number of speed-torque curve increments...
Ben... this sort of problem can be solved using Symmetrical Components Analysis! Say the...
Ben... please provide operating data: a) Line-currents. b) Supply phase-phase voltages. c)...
Topic: Power generation equipment control.
from the Forum department...
"Purpose" of VARs in an Electrical Grid
Originally posted by Hector C on 7 May, 2013 - 6:53 am
What purpose do inductive VARs serve in an electrical grid?
New Replies:
Hector... is your question, "How is the VAr component transmitted over the HVDC transmission...
Topic: Engineering and workplace issues.
from the Electrical department...
Busbar Differential Protection
Originally posted by Pal on 24 October, 2012 - 4:36 am
Busbar Differential protection for MV switchgear for 2 out of 3 (2/3) Incomer logic
New Replies:
Bob... the GSU problem you cited had to do with HV-winding capacitance differences between two...
Pal... Thanks for the your response. Nic provided some logic comments/details as a guide. But, I'm...
Originally posted by Jared Hankovsky. on 25 April, 2013 - 10:05 pm
Multiple transformers being powered up simultaneously is blowing fuses on the primary side. When powered up one at a time the fuses hold fine.
New Replies:
Jarod... sorry I should have said primary fuse-type and size! Phil Corso...
Jared Hankovsky... Please provide the following information: a) Transformer capacities. b)...
Topic: Power generation equipment control.
from the Forum department...
Iron in IP Boiler
Originally posted by dkguerry on 19 April, 2013 - 9:52 am
Iron in IP Boiler
New Replies:
Dkguerry.... can you provide a unit-of-measure, i.e., grains per gallon, or mg per liter? ...
Topic: Sensor technologies.
from the brains department...
Honeywell UV Flame Detectors
Originally posted by Brad Fanetti on 6 June, 2001 - 10:23 am
Procedure for testing the correct operation of Honeywell Flame Detectors
New Replies:
Anindya_Ray... As you had requested, the document was sent directly to your e-mail address! Please...
Originally posted by Santanu Das on 13 April, 2013 - 11:04 am
What will happen when 2 out of 3 poles of a 220 kv circuit breaker of a 330MVA Generator (of a steam power plant) is closed and one open when the generator (via GT) is connected (or synchronized)with 220kv bus?
New Replies:
Santanu... The disturbance question I replied to was just the opposite of what you described, and I...
Santanu... if closure of the faulted-breaker at the instant both the generator-side PTs and the...
Originally posted by GJRS on 20 March, 2013 - 7:12 pm
Collector ring standstill marks.
New Replies:
GJRS... please provide information on slip-ring material, brush composition, environmental...
Topic: Power generation equipment control.
from the Electrical Engineering department...
How to calculate load power demand in the 3 phase power system?
Originally posted by Minh on 14 March, 2013 - 1:42 pm
calculating the load power demand in the 3 phase power system.
New Replies:
Minh… your approach seems enthusiastic but I question your Electrical Power Engineering knowledge!...
Minh... have you completed the Steady-State Load-Flow Study? Regards, Phil Corso ...
Topic: Engineering and workplace issues.
from the Buzzinga department...
Open Circuit Calculations
Originally posted by Jerry on 10 March, 2013 - 6:16 pm
Transformer short circuit and open circuit calculations on primary end
New Replies:
Jerry... following are several Control.Com threads that discuss open-phase operation of xfmrs!! ...
Topic: Power generation equipment control.
from the Formulas needed, I'm lost department...
3-Phase unbalanced power calculation
Originally posted by EE on 7 March, 2013 - 4:20 pm
Looking for a way to verify heater elements power with measured voltage and impedance
New Replies:
EE... secondly, how were the Ohm measurements taken? Were they made with the delta intact, or...
EE... the measured ph-ph resistances, i.e., 20.0, 27.0, 20.4 don't agree with those calculated from...
Topic: Engineering and workplace issues.
from the electrical department...
Generator selection
Originally posted by Generator on 4 March, 2013 - 2:10 am
we have source of air flow app. 1000 rpm .Pl. suggest suitable single phase alternator for the same.
New Replies:
Generator... I forgot to mention viirtually all wind-power applications have a Betz factor well...
Generator… following is a procedure you can follow: 1) Determine the area, A, swept out by the...
Topic: Engineering and workplace issues.
from the EEE department...
induction generator
Originally posted by Rahul on 28 February, 2013 - 1:41 pm
Operation of induction generator
New Replies:
Rob... I suggest you search Control.Com Archives for Induction Generator threads! Regards, Phil...
Topic: Power generation equipment control.
from the Beginning of Current flow... department...
Generator Synchronization
Originally posted by Gurpreet Singh on 29 April, 2010 - 6:23 am
After the generator is synchronized with the grid AND reaches floating stage, "WHAT MAKES THE CURRENT TO FLOW"
New Replies:
Atta... It is cepsicon@aol.com Phil Corso...
Topic: Power generation equipment control.
from the Forum department...
reactive power and fuel consumption
Originally posted by Mohamed Ragab on 8 June, 2011 - 10:24 pm
how can the reactive power affect the fuel consumption
New Replies:
Prasad... your explanation is in error because even though kVA, hence armature-current, increases,...
Originally posted by Dragan on 7 February, 2013 - 5:52 pm
what happens if turbine rated power is smaller than gen nominal power
New Replies:
Dragan... Dave Amundson makes two excellent points that I completely overlooked. Based on his...
S.Zoghby, is absoluly correct. 1) There are qualified millrights that can properly couple and...
Originally posted by Abdollah on 13 February, 2013 - 4:49 pm
Is it allowed to run the gas turbine when having a battery ground fault (L64)?
New Replies:
Abdollah... Followng is a scenario that illustrates why the unit should not be kept on line! ...
Topic: Power generation equipment control.
from the Mechanical department...
SST-9000 Steam turbine
Originally posted by Dhinesh on 29 January, 2013 - 12:14 am
Siemens Supply Steam Turbine-SST-9000
New Replies:
Dhinesh... developed for use with advanced Pressurized-Water-Reactors, it features a double-flow...
Topic: Engineering and workplace issues.
from the Electrical department...
Generator Tripping
Originally posted by Thair on 12 February, 2013 - 8:33 am
Generator breaker Trips when generator connected to DG
New Replies:
Thair... how large is the load vs the load? Regards, Phil Corso cepsicon@aol.com...
Topic: Application Questions and Problems
from the Forum department...
Safety risk assessment
Originally posted by Tom Bullock on 5 February, 2013 - 11:20 am
Safety risk assessment report
New Replies:
Vahid... send me your e-mail address! Regards, Phil Corso cepsicon@aol.com...
Tom... would you like a copy of my paper, "Probabilistic Risk Assessment of Safety...
Topic: Power generation equipment control.
from the engineering department...
transformers
Originally posted by moses52 on 8 January, 2013 - 8:39 am
voltage stepping up.
New Replies:
Moses... this might be handled with Boost-Buck transformers, depending on what you meant by...
Topic: Power generation equipment control.
from the Synchronization department...
Normal Slip Speed
Originally posted by MWO on 3 January, 2013 - 9:57 pm
What is normal slip frequency for synchronization.
New Replies:
MWO... I presume the SEL Auto-Sync system uses an Anticipatory Logic Scheme! If so, then the...
MWO... which generator voltage is higher; incoming, or bus? Can you monitor the voltage-signals...
MWO... slip-rate is only one parameter during synchronization. What is the voltage differential? ...
Topic: Power generation equipment control.
from the electrical department...
Generator in parallel with transformer
Originally posted by sangeetha on 19 December, 2012 - 10:44 pm
What are the things to be checked before running a DG in parallel with a trafo.
New Replies:
Nic... amendment to my earlier post: Failure-to-trip probability, w/o tie-breaker, is (N)x(Qf),...
Nic... I too meant no disrespect of your knowledge, design experience, or commissioning skills. ...
Sangeetha... There is no way the DG-set can escape serious damage if the Main-Bus load is suddenly...
Topic: Motion control, servos, steppers, etc.
from the motor winding department...
no load power of a motor
Originally posted by praveen panthri on 23 December, 2012 - 2:11 am
How much power taken by motor in no load condition?
New Replies:
Praveen... your assumption is incorrect: The relationship between no-load current and no-load...
Topic: Motion control, servos, steppers, etc.
from the Forum department...
Braking systems of industrial fans
Originally posted by Newtothis on 14 December, 2012 - 1:35 pm
control strategies for braking and industrial fan
New Replies:
NTT... What do you mean by "Control Methods?" Do you mean your own design? Or...
Newtothis... there are well over 250 "Braking" threads in the Control.Com Archives. At...
Topic: Engineering and workplace issues.
from the Electrical Engineering department...
Excitation Transformer Sizing: Short Circuit Current
Originally posted by Mike on 13 December, 2012 - 6:12 pm
Excitation transformer sizing details
New Replies:
Mike... the answer to your question is no! That is, a transformer's kVA capacity is determined by...
Topic: Power generation equipment control.
from the Power Generation department...
Load Angle of Alternator
Originally posted by rock086 on 2 December, 2012 - 9:34 am
Why the load angle of the alternator is kept low (20-40 degree)?
New Replies:
Rock… The formula refers to Steady-State operating conditions, i.e., no changes. At 90º the system...
Topic: Continuous process industries, DCS questions.
from the Forum department...
Current Loop
Originally posted by allenbradley on 22 November, 2012 - 12:28 am
The 24 VDC from the safety barrier drops down to 0 VDC every time I connect my temp transmitter.
New Replies:
A-B... it could depend on the type of barrier. 1) What happens to the input-voltage to the...
Topic: Engineering and workplace issues.
from the Electrical department...
Starting of motor through star delta
Originally posted by Shaheed on 13 November, 2012 - 3:02 am
Running a three phase 400V 50HZ 2900RPM induction motor through a star delta starter
New Replies:
Shaheed... I will use my Gi.Fi.E.S. method (pronounced Jiffy's) for an approximate solution....
Shaeed... what is the motor size? Phill Corso (Cepsicon@aol.com)...
Topic: Engineering and workplace issues.
from the Electrical department...
Static frequency converter
Originally posted by chandru on 13 November, 2012 - 5:41 am
questions about using a static frequency converter
New Replies:
Chandru.. If your application is related to a motor drive, then contact Danfoss If your...
Topic: Continuous process industries, DCS questions.
from the Power Transformer department...
Generator Transformer for plant
Originally posted by pmmeeran on 18 March, 2010 - 4:10 pm
Replacing the power transformer by another vector group transformer
New Replies:
Mr. Jamiyandorj... your questions encompass a rather large topic. But if maximum reliability is the...
Topic: Engineering and workplace issues.
from the Private department...
Question about two-phase generator
Originally posted by Angel on 6 November, 2012 - 12:28 am
What is the correct answer of this question?
New Replies:
Angel... because the generated voltages are 90° apart and the phase loads equal and resistive, the...
Originally posted by hydro on 18 October, 2012 - 10:51 pm
Is bringing an induction generator online from runaway speed similar to starting a motor DOL only torque is in the opposite direction?
New Replies:
Hydro... in a nutshell, yes! I want to clarify my statement that "... stress is similar to...
Hydro... the influence a motor's parameters has on its generator-action torque can be seen in the...
Select Page: 1 2 3 4 5 6 7 8 9 10 11 Next
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
Vote anarchist
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive