1
Control.com member...
Member Information and Posts by RobertWillis
from the yep department...
altivar71/ioscan
Topic: Communications systems and equipment.
Originally posted by jagg on 17 November, 2009 - 10:12 pm
Would like to setup a alt71 to comm. with our plc quantum with a noe77111 card.
New Replies:
What type of device are you going to use to control the Altivar 71 Drive? If it is a Modicon PLC,...
from the AUTOMATION department...
MODBUS TCP/IP communications
Topic: Communications systems and equipment.
Originally posted by GENJUA on 18 November, 2009 - 4:19 am
We are trying to built up communication of power meter pm-710 with egx-100.
New Replies:
The EGX100 supports a total of 32 open TCP/IP connections at one time with the 2.7 firmware. It...
from the Forum department...
unity pro
Topic: Software, including programming, OS issues, etc.
Originally posted by unity pro on 15 June, 2009 - 1:01 pm
Difference in unity pro between The plc and the pc
New Replies:
The only way to view the difference would be to use the Unity Pro DIF Software which provides you...
from the Instrument department...
Modicon 984-785E series PLC
Topic: PLCs and related questions.
Originally posted by rizwan on 18 November, 2008 - 10:41 pm
We are unable to communicate with Modicon PLC 984-785E series PLC through laptop having Modsoft ver 2.2...
New Replies:
You need to provide us some additional information such as the computer make and model, operating...
from the SERIOSE department...
Problem Connecting XBTF V2 to Premium PLC
Topic: Human-Machine Interface and SCADA.
Originally posted by JABBARI on 2 December, 2008 - 4:46 am
We changed the XBTF and we cannot connect to the PLC.
New Replies:
Did you change the terminal type in the application to reflect that you are using the newer V2...
from the Forum department...
Concept 2.6
Topic: PLCs and related questions.
Originally posted by Oliver on 26 November, 2008 - 5:54 pm
Do any of you have a description for the symbols of Concept 2.6?
New Replies:
Please clarify what you are looking for. In the Concept Software there are Variable Names and...
from the Forum department...
TSX Premium Processor I/O fault
Topic: PLCs and related questions.
Originally posted by Eric on 15 November, 2008 - 8:47 am
New to the TSX PL7PRO software
New Replies:
What version of PL7 Pro do you have? The I/O ERR light will come on whenever there is a error...
Topic: PLCs and related questions.
Originally posted by Dallas on 7 August, 2008 - 12:53 am
I am currently working on a PLC project. I would like to establish a master and slave communication using Modbus protocol.
New Replies:
The I/O Scanner is designed to work with a Ethernet connection. Since you indicated that you want...
from the modbus plus department...
Modbus Plus interface cards
Topic: Human-Machine Interface and SCADA.
Originally posted by av on 29 October, 2008 - 8:40 am
Modbus Plus interface card options
New Replies:
Schndier Electreic offers the following Modbus Plus Interfaces. 416NHM21234 PCMCIA Type 3...
from the information department...
Modicon
Topic: Information resources, documentation.
Originally posted by donna on 29 October, 2008 - 6:25 pm
Difference between two ISA, interface cards
New Replies:
The Modbus Plus ISA-SA85 adapter (AM-SA85-000) has been replaced with the (AM-SA85-030). This is...
from the Forum department...
Read PM710 with Modicon M340
Topic: Programming languages.
Originally posted by OMI on 29 October, 2008 - 6:10 am
I don't find the function to read the information of the PM710
New Replies:
Take a look at the READ_VAR and WRITE_VAR functions in Unity. In Unity Pro Version 4.0 there is an...
from the Automation List department...
Slow communication between Citect SCADA and Quantum
Topic: Communications systems and equipment.
Originally posted by Chris on 27 June, 2008 - 12:23 am
Slow communication between Citect SCADA and Quantum results in long time SCADA's screens opening.
New Replies:
Chris: Please describe your Unity Pro application that is running in your 140CPU767160...
from the Forum department...
ControlLogix vs Quantum PLCs
Topic: PLCs and related questions.
Originally posted by Ryno83 on 29 September, 2008 - 10:58 pm
Pros and cons between ControlLogix and Quantum
New Replies:
James, your information about which of the original Modicon Quantum controllers can be FIELD...
1
 
 
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.