Member Information and Posts by SPRTime synchronisation between DCS, PLC and all subsystems.
New Replies:
Hi
Every DCS has a windows platform interface. With this, you can have all your DCS/PLC systems...
Compiling CL programs and putting them into use on TDC-3000
New Replies:
1. The CL you wish to change, must have a process module point, associated. Where does this point...
Getting random serial link Fault in Preferred Rack of LM.
New Replies:
Some clarity required here
1. When the fault appears, the processor swap-over occurs. Did you...
Try end termination resistances in SIOM. They should be placed in physically the last IO rack.
...
Can anybody suggest Jumper Setting in Two Zip Drives mounted in single US Station for Honeywell TDC-3000/TPS ?
New Replies:
You may require to review jumper settings if you have dual zip drives in single US.
Consider...
I want to connect C300 DCS to VB 6.0 to create web page where i can display my boiler temperature and pressure etc.
New Replies:
Hi
C300 EPKS supports ODBC across firewall. Have a firewall in place, configure it to allow only...
Modbus for control data sharing between controllers. Is it advisable?
We are facing problem while downloading tag number details on line in Experion PKS DCS.
New Replies:
HI EVERYBODY
First of all the difference between TPS & EPKS:
1. In TPS we build separate...
from the Control Software Administration department...
Upgrade TPS system from GUS to Experion PKS StationIs Upgrade TPS system from GUS to Experion PKS Station is right or wrong?
New Replies:
> I think this offer is not for migration project from TPS to EPKS.
---- snip ----
> New...
> 1- SW upgrades for all my plant TPS system at current release (TPN from Rel 610 to Rel 682 ,...
How to increase HPM box numerics over 5000?
New Replies:
> An Array point must be used to access index numbers greater that 4095 over the LCN. <
Hi...
4095 is the highest no. of numerics you can configure in the HPM node specific configuration....
Modicon 424-2 Quantum with redundant NOE 771-00 communication issues with Honeywell Experion C300 DCS
New Replies:
>- Experion scada channel that reads and write data from the PLC
THIS IS GUESS, IS THE...
Which DCS Systems use "Client and Server Architecture"
New Replies:
Hi SMS
What you said is correct for PLC-SCADA systems where clients are totally dependent on...
Hi Jorge
All DCS are client-server based systems.
The reason is simple. DCS means a...
I am interested in knowing the requirements for Honeywell Experion PKS system upgrade from 301x to 310x.
New Replies:
Your existing hardware will support R301 to R310 upgrade. Even the OS on your existing R301 system...
Point to Point Connection, C300 to HPM
New Replies:
1. HPM SI will not serve the purpose of control as it works on modbus and modbus is not...
Comparison among different makes of DCS used to control medium size of process
New Replies:
EPKS systems comparison:
1. EPKS R400 will be launched soon, but before that R3XX also is a...
TDC3000-Ethernet
New Replies:
Many methods to do this
1. As Walt said, upgrade to Experion
2. Install an APP node or PHD node...
connecting my older Honeywell 620 controller to a modern Operator Interface using a converter
New Replies:
Buy a new winloader for your 620. It works on any windows platform, much faster and easy to take...
Details about migration of Foxboro DCS to EPKS (Honeywell DCS) required.
New Replies:
Try this. It might help. Register & login is required to access.
...
I want some detailed information about the relation between Honeywell C200 and Allen Bradley ControlLogix...
New Replies:
C200 & ControLogix use the same protocol CNI and backplanes may be exactly same.
YOU CANNOT...
Engineering Repository Data Base structure for Honeywell-Experion DCS
New Replies:
Hi
Use Bulk Build/Bulk Edit tools in control builder.
Use xml exports in control builder.
...
What is the right location in the network infrastructure of implementing APC (PKS Experion)
New Replies:
Put the APC in the DMZ of ur firewall. The reason is perfect isolation.
For the OPC connectivity...
US, NIM, UCN fails on checkpointing to a zip cartrdige.
Any demo-software available?
New Replies:
Hi Rudi
Thanks for the reply. I wanted to know how did you install EPKS on your laptop in the...
Hi Adil
Yes i have worked with Plantscape. Hope it is with C200 and controlnet. What is wrong...
Experion PKS is a bundled package with C300/C200 hardware. You cannot have a convincing demo with...
from the Process control department...
Status and performance monitoring for Honeywell c-200 controllerCreating status and performance monitoring for Honeywell c-200 controller
New Replies:
Hi Pritesh
C200 controller performance statistics:
1. CPU usage in % for all the 40 phases
...
LCN Suspect Alarm after connecting app-node TPN server with OPC optimizer
New Replies:
green n yellow cable segments between nodes should have same length. Moreover, in LCN suspect...
Seeking help to rectify frequently appearing Suspect LCN Cable alarm at our site.
New Replies:
LCN troubleshooting is a bit tricky and requires patience.
If the noise pattern is random on...
Point details retrieval from ESVT.
New Replies:
Hi
Unable to understand your difficulty. What point details are you looking for? In case of...
How to print tag nos. and descriptions of historised points in TDC 3000
New Replies:
To find out parameter names (specifically for UCN nodes/UCN node specific conf/tags built on NIM)...
Select Page: 1
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.
Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.
Fortune
Hain't we got all the fools in town on our side? And hain't that a big
enough majority in any town?
-- Mark Twain, "Huckleberry Finn"