Member Information and Posts by bayoolaniyan
Topic: Power generation equipment control.
from the Instrument department...
Turbine FSNL
Originally posted by Bayo Olaniyan on 17 July, 2012 - 8:58 am
GE F9001E Not staying on FSNL when generator breaker opens on Under Frequency.
New Replies:
Thank you very much CSA. I will carry out all you advice and get back to you. I appreciate....
Thanks a lot.The alarm printer in this site is defective. The alarm that comes are: 1. under...
1. The Unit did not behave like this before CI. When the Unit is on Governor Control, and the...
Topic: Human-Machine Interface and SCADA.
from the Maintenance te-a-tet department...
EX 2000 not changing to auto
Posted by Bayo Laniyan on 4 October, 2011 - 10:40 am
HMI not changing from FVR (manual exciter regulation) to AVR.
Topic: Power generation equipment control.
from the power department...
Exhaust Thermocouple Problem
Originally posted by kiran on 15 August, 2011 - 2:56 pm
Gas turbine trip due to one of the Exhaust thermocouple got open.
New Replies:
These are my answers: 1. If only 1no TC is reading low, this can be looped to a good one in...
Topic: Power generation equipment control.
from the Instrument&Control department...
re- exhaust spread trip
Posted by Bayo Olaniyan on 24 March, 2011 - 3:41 am
what is the effect of looping the exhaust thermocouple from the low spot to any of the higher ones?
Topic: Power generation equipment control.
from the Instrument&Control department...
Exhaust Spread
Originally posted by Bayo Olaniyan on 18 March, 2011 - 10:52 am
I am working on a frame 9E GE machine. At above 50MW the Unit trips on exhaust spread.
New Replies:
>How could you get the alarm if TTSP1 TTXSPL?< Thanks for the feedback. As the unit gets...
Topic: Power generation equipment control.
from the exhaust fun department...
exhaust spread
Originally posted by Bayo on 16 March, 2011 - 3:28 am
After combustion inspection,I have been having exhaust trip at 50mw. This Ge frame 9E.
New Replies:
The manufacturer is GE Frame 9E Fuel is natural gas ttxd_1-371; ttxd_2-376; ttxd_3-386;...
Topic: Power generation equipment control.
from the Forum department...
MS5001 causes of excessive exhaust spread?
Originally posted by Maaz on 15 February, 2011 - 9:59 am
What are the main causes of excessive exhaust spread in Ge Frame V (MS5001) machines? Does leaking/passing of compressor bleed valves has any effect on exhaust spread?
New Replies:
> Thanks Bob for your reply. Last maintenance job on this machine was >carried out in 2007...
Select Page: 1
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
Coward, n.:
One who in a perilous emergency thinks with his legs.
-- Ambrose Bierce, "The Devil's Dictionary"
Advertise here
advertisements
Servo, stepping motor control, analog & web HMI in one system!
Control.com is the largest Automation community on the web. Learn how to advertise here now...
Time to incorporate data handling, web HMI and motion in one system!
Servo, steppers, analog, digital & web HMI - Fully Integrated!
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive